Laserfiche WebLink
<br />FORM 900-A-91 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 9 - Residential Point System Method <br />Department of Community Affairs <br /> <br />Climate Zones <br />CENTRAL 4 5 6 <br /> <br />PROJECT NAME <br />AND ADDRESS: yr <br /> <br />~ <br />~~ '? /, 7, ;..J. d- 4t:: <br />OWNER: 6f'rJ/f'N't/eu. ~. <br /> <br /> <br />15/JeIC <br /> <br />BUILDER: CC / -Z",Il/C <br /> <br />:Ij ERMITTING ,_.LJU / r <br />OFFICE: ZIf!!'iP~)"_u-....... <br /> <br />PERMIT ~J c..- / 8 <br />NO.:~ <br /> <br />CLIMATE <br />ZONE: <br /> <br />JURISDICTION <br />NO.: <br /> <br />41iJ sO 60 <br />~ <br /> <br />NEW CONSTRUCTION [1J.. IF MULTIFAMILY, NUMBER OF CONDITIONED ~ sa, GLASS AREA AND TYPE <br /> UNITS COVERED BY ITIJ FLOOR AREA FT. CLEAR TINT,FILM,SOLAR SCREEN <br />ADDITION D THIS SUBMITTAL: PREDOMINANT rno SINGLE- [[ill sa, <br /> SINGLE- [1]1]ill sa, <br />MULTIFAMILY ATTACHED D ~K IF THIS SUBMITTAL EAVE OVERHANG FT PANE FT. PANE FT. <br />LENGTH .' <br />SINGLE-FAMILY DETACHED ~ REPRESENTS A WORST CASE PORCH OVERHANG [E 0 DOUBLE- [[ill sa, DOUBLE- [[ill sa, <br />CONDITION: D LENGTH . F1 PANE FT. PANE FT. <br /> <br /> NET WALL AREA AND INSULATION <br />EXTERIOR MASONRY R = EXTERIOR FRAME R = EXTERIOR STEEL R = EXTERIOR LOG R = <br />~SO, m.o [[]]I] SO, rn [[]]I] SO rn [[]]I] SO rn <br /> FT. FT. FT. FT. <br />ADJACENT MASONRY R - ADJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG R = <br />[[]]I] SO rn.D [1illll] SO, [il] [[]]I] SO, rn [[]]I] SO, rn <br /> FT. FT. FT FT. <br /> <br /> CEILING AREA AND INSULATION FLOOR TYPE AND INSULATION <br />UNDER ATTIC R= SINGLE ASSEMBLY R= SLAB PERIMETER R= RAISED WD 0 CON 0 R= <br />UELJill~~ ~ [[]]I] so, rn [Z]lill] FT. rn [[]]I] sa, rn <br />FT. F1 <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HVAC CREDITS HOT WATER SYSTEM HOT WATER CREDITS <br />IN 00 CENTRAL D ELECTRIC STRIP ~ HEAT D CEILING FANS ex ELECTRIC SO LAR: o.rn <br />UNCONDITIONED <br />SPACE R = D ROOM D NATURAL GAS PUMP D CROSS VENTILATION D NATURAL GAS SF. = <br /> HEAT RECOVERY (CHECK) D <br />rn. [lJ D PACKAGE TERMINAL D ROOM UNIT OR D OTHER D WHOLE HOUSE FAN o OTHER FUELS <br />FUELS DEDICATED <br />AIR CONDITIONER PACKAGE TERMINAL D ATTIC RADIANT D NONE HEAT P~MP: 0 .rn <br />IN CONDITIONED D NONE HEAT PUMP D NONE <br />SPACE R = BARRIER EF, - <br />rn.D SEER/EER = [L]Q].[g COP I HSPF I [l].~ D MULTIZONE EF = . [i[1] NUMBER OF rn <br />AFUE = BEDROOMS = <br /> <br />INFIL TRA TION ~ [RlliJillIJ ~.[1] <br />PRACTICE USED X 100 = <br />o #1 111 #2 D #3 TOTAL AS-BUILT POINTS TOTAL BASE POINTS CALCULATED E.P.1. <br />CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS. <br /> <br />I hereby certify that the plans and specifications covered by the calculation are in compliance with the <br />Florida Energy Code, <br /> <br />PREPARED BY: <br /> <br />DATE: <br /> <br />T t:> -?-C; I <br /> <br />Review of plans and specifications covered by this calculation indicates compliance with <br />the Florida Energy Code, Befor nstru 'on is completed, this build in ill be inspected <br />for compliance in accordanc i Se 553,908, F,S, -. <br /> <br /> <br /> <br />DATE: <br /> <br />I hereby certify that t~l~ce <br />OWNER AGENT:1l /U . <br /> <br />9A I PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904,1 Maximum of 0,34 CFM per linear foot of operable sash crack (includes sliding glass doors). >< <br />EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. fl. of door area: solid core, wood panel, insulated or glass doors only, ~ <br />ADJACENT DOORS <br />EXTERIOR JOINTS 904,1 To be caulked, gasketed, weatherstripped or otherwise sealed. x.. <br />& CRACKS <br />WATER HEATERS 904,2 Comply with efficiency requirements in Table 9-7A. Switch or clearly marked circuit breaker (electric) ~ <br /> or cutoff (gas) must be provided. External or built-in heat trap required, <br />SWIMMING POOLS 904.3 Spas & heated pools must have covers (except solar heated), Non-commercial pools must have a AJiJ <br />& SPAS pump timer. Gas SDa & pool heaters must have minimum thermal efficiency of 78%. <br />SHOWER HEADS 904,5 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG, X <br />HVAC DUCT 904.6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned \ <br />INSULATION space and air handlers located in attics must be insulated to a minimum R-4.2 (R-6 after 1/1/92). <br />& INSTALLATION <br />HV AC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system, 1"1.: <br />INSULATION 904.9 Ceilings-Min. R-19. Common Walls-Frame R-11 or CBS R-3. Common Ceilings & Floors R-11. )( <br /> <br />- 1 - <br />