Laserfiche WebLink
<br />FORM 500A-89 <br />Non.Resldentlal Buildings <br />Residential Buildings over 3 stories <br /> <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />SECTION 5 . BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH <br />ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS <br /> <br />All CLIMATE ZONES <br /> <br /> <br />ZONE: <br />BUilDING CLASSIFICATION S: <br />BUilDING PERMIT NO.: .Y' <br />PERMITTING OFFICE: <br />JURISDICTION NO.: <br /> <br /> <br /> BUILDING INFORMATION f..,./n+eA <br />WALLS ne.-r ROOF/CEILING FLOORS DOORS '-- GLASS <br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE .\ U AREA <br />Concrete (CBS) -/I J~q4 Under allic ~'i iAtXJ Slab-on-grade 0 /1'<00 Wood Single. wall lo.~ 30G <br />Wood Irame Single Assembly Raised Wood Metal ~ 1'1 6:1, Double, wall <br />Metal frame Other: Raised concrete Insulated Single, roof <br />Insulation R-value Insulation R-vatue Insulation R-value Other Double, roof <br /> <br /> SYSTEMS INFORMATION . <br />AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUtH TYPE <br />Unitary & Heat Pump er,3 Ne.w I Uhlt~" Central Heat Pump 7, 5 HSPF Electric ~ <br /><65,000 Btu/h _ SEER ~.JL:2..-r < 65.000 Btu/h - Resistance <br />~ 65,000 Blu /h _ EER z.""S~ ~65,000 Blu/h _COP - Dedicaled Heat Pump 0 <br />Water cooled _EER - Water cooled _COP - Gas <br />Evaporatively cooled _EER Evaporatively cooled _COP - Natural 0 <br />- 0 <br />PTAC _EER Eleclric resistance _COP - LPG <br />- 0 <br />Chillers _COP Gas / Oil (circle one) Oil <br />- < 225,000/300,000 Btu/h _ AFUE 0 <br />Other: - HRU <br /> - - > 225,000/300,000 Blu/h Et Other: <br />LIGHTING ~ r;&f 4- /800 Lighting Budget (from Table 5-13): '2..0 <br />Total lighting Wallage ~ : Total Conditioned Floor Area - Walls/sq. It: """" /,44- <br /> <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.) <br /> COMPONENTS SECTION REQUIREMENTS CHECK <br />Windows 502.4 Maximum of 0.5 cfm per linear fool of operable sash crack. V" <br />Doors , 502.4 Maximum 0111.0 elm per linear foot of operable sash crack. V <br />Joints /Cracks 502.4 To be caulked, gasketed. weatherslripped. or otherwise sealed. !/'" <br />Reheat 503.3 Supply air reslricted to set cold/hot deck temperature to meet load of worst case zone. i/' <br />Ventilation 503.4 Supplied with readily accessibte switch lor shut-olf and/or volume reduction when ventilation V <br /> is nol required. <br />HVAC Efliciency 503.4 Minimum etficiencies - Healing: Tables 5.5, 5-6; Cooling: Tables 5.7, 5-8, 5.9. V <br />Transport Energy 503.5 Minimum 01 8.0 V <br />Balancing 503.6 Provide means tor balancing HVAC air system & waler distribution system. V <br />HVAC Controls 503.7 Separate readity accessible manual or aulomatic thermoslat for each syslem. V <br />HVAC Duct 503.9 Conslrucled in accordance with industry standards & local mechanical codes. Duels must be insulated v' <br />Construction to minimum R = A tl15 (hr OF ft 2 I Btu). <br />Piping Insulation 503.10 In accordance with Table 5-10. v' <br />Waler Heaters 504.2 Must bear ASHRAE label indicating compliance with ASHRAE Standard 90 or comply with efficiency and standby <br /> loss requirements. Switch or clearly marked circuit breaker (eiectric) or cut-off (gas) must be provided. Heat traps V <br /> required. Must meet minimum water heating equipment efficiencies In Table 5.11 after 1/1/90. <br />Swimming Pools 504.2 Spas & heated pools must have covers. Non-commercial pools musl have pump limer. vi' <br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 75% (78% after 1/1/90). <br />Hot Water 504.4 Insutation is required for recirculaling systems. Piping heat loss is limited to 17.5 Btu /h I linear foot 01 <br />Pipes pipe; see Table 5.12. V <br />Water fixtures 504.5 Water flow restricted to maximum of 3 gpm at 80 psig: loilets maximum 3.5 gallon lIush. Public lavatory V <br /> fixture maximum 1I0w 01 .5 gpm or .5 gallon if has sell.closing valve. <br />liqhtinq 505.1 liqhtinq power budqets are listed in Table 5.13; Ballast efficacy-tactors are listed in Table 5.14. V <br /> <br />Uo wall Allowable 0.. I ~ Uo wall Actual , t'J ., rl 11 complying under the provisions 01 S. 502.1. enter tho combined Uo values lor the entire envelope <br />Uo roof/ceiling Allowable . 1'" Uo roof/ ceiling Actual ", '7/5 in this seclion. <br />Uo 1I00r Allowable Uo 1I00r Actual Uo envelope Allowable Uo envelope Actual <br />OTTV wall Allowable -~O,.'f OTTV wall Aclual /2. ~ <br />OTTV roof/ ceiling Allowable g.&> om roof /ceiling Actual 3, /~ <br /> <br />All plans and specilications shall be signed and si:aled by a Florida registered engineer or archilect <br />wilh the excepfions provided lor in Section 481.229, F.s. and See lion 471.003, F.S. I hereby certify <br />that the ptans and sp . cations cov red :?thi catculation are in compliance with Ihe Florida <br />Energy Code. . <br />SIGNATURE: .. P'.. ~ <br />DATE: 8 -20- '1' <br /> <br />Review ?I the plans and speCifications covered by this calculalion indicates compliance with <br />the FlOrida Energy Code. Before construction is completed, this building will be inspected for <br />compliance in accordance wilh Section 5 3.908 F.S.. <br /> <br />BUILDING OFFICIAL: <br />DATE: <br /> <br /> <br />'" <br /> <br />~fb.- <br />