<br />FLORIDA ENERGY EFFICIENCY CODE
<br />FOR BUILDING CONSTRUCTION
<br />Section 9 - Residential Point System Method
<br />Department of Community Affairs
<br />
<br />Climate Z~qes
<br />CENTRALd/5 6
<br />
<br />
<br />PROJECT NAME
<br />AND ADDRESS:
<br />
<br />NEW CONSTRUCTION 0'
<br />ADDITION 0
<br />MULTIFAMILY ATTACHED 0
<br />SINGLE-FAMILY DETACHED er
<br />
<br />CHECK IF THIS SUBMITTAL
<br />REPRESENTS A WORST CASE
<br />CONDITION: 0
<br />
<br />CONDITIONED ~\ I I..., sa,
<br />FLOOR AREA L.Ll1df::l[1J FT.
<br />PREDOMINANT rn [g
<br />EAVE OVERHANG 2- 0 FT.
<br />~NGm .'
<br />PORCH OVERHANG IT:::;l Cl
<br />LENGTH ~. ~ FT.
<br />
<br />GLASS AREA AND TYPE
<br />
<br />CLEAR TINT,FILM,SOLAR SCREEN
<br />
<br />SINGLE- ~SCl, SINGLE- DTIJ sa,
<br />~~~FT. ~~ FT.
<br />
<br />DOUBLE- DTIJ SCl, DOUBLE- DTIJ sa,
<br />~E FT. ~E FT.
<br />
<br /> NET WALL AREA AND INSULATION
<br />EXTERIOR MASONRY R EXTERIOR FRAME R EXTERIOR STEEL R = EXTERIOR LOG R -
<br />mmW rn.[9 [JJJ]] SO, ITJ [JJJ]] SO, ITJ [ITillso ITJ
<br /> FT. FT FT
<br />ADJACENT MASONRY R - ADJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG R -
<br />[JJJ]] SO, ITJ.O [JJJ]] SO, ITJ [JJJ]] SO, ITJ [JJJ]] SO ITJ
<br />FT. FT FT. FT
<br />
<br /> CEILING AREA AND INSULATION FLOOR TYPE AND INSULATION
<br />UNDER ATTIC R- SINGLE ASSEMBLY R= SLAB PERIMETER R= RAISED WD 0 coNj?"" R=
<br />~sa, [mJ [JJJ]]sa. ITJ ~FT. rn []JJJJsa. ITJ
<br /> FT. FT. FT.
<br />DUCTS COOLING SYSTEM HEATING SYSTEM HVAC CREDITS HOT WATER SYSTEM HOT WATER CREDITS
<br />IN ZCENTRAL o ELECTRIC STRIP ~EAT .0 CEILING FANS ..0ELECTRIC SOLAR: O.ITJ
<br />UNCONDITIONED
<br /> o ROOM o NATURAL GAS PUMP .0'CROSS VENTILATION o NATURAL GAS SF, =
<br />SPACE R = HEAT RECOVERY ,CHECK: D
<br />rn.~ o PACKAGE TERMINAL o ROOM UNIT OR o OTHER o WHOLE HOUSE FAN D OTHER FUELS
<br /> FUELS DEDICATED
<br />IN CONDITIONED AIR CONDITIONER PACKAGE TERMINAL o NONE o ATTIC RADIANT o NONE HEAT P~MP: 0 ,ITJ
<br />o NONE HEAT PUMP
<br />SPACE R = BARRIER EJ. -
<br />ITJ,O SEER/EER = rn,~ COP I HSPF I ~, [B1Q] o MULTIZONE EF = ,~~ NUMBER OF ~
<br />AFU E = BEDROOMS =
<br />
<br />INFIL TRA TION ~ LIiliUIiliJ D2liJ. ~
<br />PRACTICE USED X 100 =
<br />0#10#20 #3 TOTAL AS-BUILT POINTS TOTAL BASE POINTS CALCULATED E.P.1.
<br />CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS.
<br />
<br />I hereby certify that the plans and specifications covered by the calculation are in compliance with the Review of plans and specifications covered by this calculation indicates compliance with
<br />Florida Energy Code, the Florida Energy COdr~nstruction is completed, this building will be inspected
<br />PREPARED BY: DATE: for compliance in accordanc i ~53',908, F,S, - f:1
<br />I hereby certify th,t t ' , 'i~ce ~ the Florida Energy Code, \ I . J q BUILDING OFFICIAL: I .J -" ...., ~
<br />i .. -- 9(
<br />- .,Ll )) uATE: \ '22 / // :2-7
<br />OWNERAGENT: ' , .~ DATE:
<br />9A I PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />WINDOWS 904.1 Maximum of 0.34 CFM per linear foot of operable sash crack (includes slidino olass doors).
<br />EXTERIOR & 904,1 Maximum of 0.5 CFM per sq. ft. of door area: solid core, wood panel, insulated or glass doors only,
<br />ADJACENT DOORS
<br />EXTERIOR JOINTS 904.1 To be caulked, gasketed, wealherstripped or otherwise sealed.
<br />& CRACKS
<br />WATER HEATERS 904,2 Comply with efficiency requirements in Table 9-7A. Switch or clearly marked circuit breaker (electric)
<br /> or cutoff (gas) must be provided. External or built-in heal trao reauired.
<br />SWIMMING POOLS 904.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a
<br />& SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 78%,
<br />SHOWER HEADS 904.5 Water flow must be reslricted to no more than 3 oallons per minute at 80 PSIG,
<br />HVAC DUCT 904,6 All ducls, fittings, mechanical equipment and plenum chambers shall be mechanically attached,
<br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned
<br />INSULATION space and air handlers located in attics must be insulated to a minimum R-4,2 (R-6 after 1/1/92),
<br />& INSTALLATION
<br />HV AC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system.
<br />INSULATION 904.9 Ceilings-Min. R-19. Common Walls-Frame R-ll or CBS R-3. Common Ceilings & Floors R-l1,