<br />FORM 1000-C-91
<br />SMALL ADDITIONS
<br />AND RENOVATIONS
<br />
<br />FLORIDA ENERGY EFFICIENCY CODE
<br />FOR BUILDING CONSTRUCTION
<br />Section 10 - Residential Prescriptive Compliance Method
<br />Department of Community Affairs
<br />
<br />Climate Zones
<br />CENTRAL 4 5 6
<br />
<br />COMPLIANCE WITH SECTION 10 OF THE FLORIDA ENERGY EFFICIENCY CODE MAY BE DEMONSTRATED BY USE OF FORM100OC-91FOR ADDITIONS OF 600 SOU ARE FEET OR LESS, AND RENOVATIONS
<br />TO SINGLE AND MULTIFAMILY RESIDENCES, ALTERNATIVE METHODS ARE PROVIDED FOR ADDITIONS BY USE OF FORM 1000A-91 or 9OOA-91
<br />
<br />
<br />CLIMATE 4
<br />ZONE:
<br />JURISDICTION
<br />NO.:
<br />
<br />DsD6D
<br />[]]]]I]
<br />
<br />ADDITION
<br />
<br />IF MULTIFAMILY. NUMBER OF
<br />UNITS COVERED BY
<br />THIS SUBMITTAL OJ]
<br />
<br />CONDITIONED
<br />FLOOR AREA
<br />PREDOMINANT
<br />EAVE OVERHANG
<br />LENGTH
<br />PORCH OVERHANG
<br />LENGTH
<br />
<br />ITJ,D FT
<br />m.D FT
<br />
<br />SINGLE
<br />PANE
<br />
<br />DOUBLE
<br />PANE
<br />
<br />NEW GLASS AREA AND TYPE
<br />CLEAR TINT,FILM.sOLAR SCREEN
<br />~SO SINGLE DID SO
<br />~ FT PANE FT
<br />DID SO DOUBLE. DID SO
<br />FT PANE FT
<br />FLOOR TYPE AND INSULATION
<br />WOOD MASONRY
<br />RAISE~ = [[1 D RAISE~ = m.D
<br />
<br />COM~O~ [[1 D COM~O~ en
<br />
<br />SLAB-ON- _ IT] D
<br />GRADE, R - ,
<br />
<br />~
<br />
<br />MULTIFAMILY ATTACHED 0
<br />SINGLE-FAMILY DETACHED 0
<br />
<br />RENOVATION
<br />
<br />UEt%
<br />
<br />WALL TYPE AND INSULATION
<br />WOOD FRAME MASONRY
<br />EXTER~O~ IT] , D EXTE~O~ [L]].D
<br />
<br />ADJAC~N~ IT] . D ADJA~E~T ITJ. D
<br />COMMON IT] D COMMON: ITJ
<br />R - , R ~ .
<br />
<br />CEILING TYPE AND INSULATION
<br />
<br />FOR ADDITIONS ONLY:
<br />
<br />PERCENTAGE
<br />OF GLASS
<br />TO FLOOR
<br />
<br />UNDER ATTIC:
<br />R c
<br />SINGLE ASSEMBLY
<br />R =
<br />
<br />ITJ.D
<br />rn,D
<br />R= m.D
<br />
<br />COMMON:
<br />
<br />DUCTS COOLING SYSTEM HEATING SYSTEM HOT WATER SYSTEM
<br />IN 0 CENTRAL 0 NONE 0 ELECTRIC STRIP 0 HEAT PUMP o ELECTRIC 0 SOLAR
<br />UNCONDITIONED o ROOM o NATURAL GAS 0 o NATURAL GAS 0
<br />SPACE' R = RooM/PTHP HEAT RECOVERY
<br />m.D ~TAC o ,OTHER FUELS 0 NONE ~THER FUELS o OED, HEAT PUMP
<br />IN CONDITIONED NO NEW SYSTEM 0" NO NEW SYSTEM NO NEW .[[1 SF/EF = ~.CD
<br />SPACE: R = m.D IT] SYSTEM EF =
<br />llilD SEER/EER = COP I HSPF I AFUE = NUMBER OF BEDROOMS = CD
<br />
<br />I hereby certify that the plans and specifications covered by the calculation are In compliance WIth the
<br />Florida Energy Code
<br />
<br />PREPARED BY
<br />
<br />DATE
<br />
<br />ReView of plans and speCifications covered by thi!:. calculation Indicates compliance with
<br />the Florida Energy Code. Before construction is completed. this building will be inspected
<br />for compliance In accordance With Section 553.908. F.S
<br />
<br />I hereby certify that this b
<br />OWNER AGENT:
<br />
<br />9 is iniomnnce, With thi\Flori~a~ Code
<br />~.J<._ ~.\U'~/mTE
<br />
<br />/z/~ff1
<br />. t
<br />
<br />BUILDING OFFICIAL
<br />
<br />DATE
<br />
<br />TABLE 10AI MINIMUM REQUIREMENTS FOR ALL PACKAGES
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />WINDOWS 904,1 Minimum of 0,34 CFM per linear foot of operable sash crack (includes sliding glass doors), V
<br />EXTERIOR & 904,1 Maximum of 0,5 CFM per sq, It, of door area: solid core, wood panel, insulated or glass doors only. V
<br />ADJACENT DOORS
<br />EXTERIOR 904,1 To be caulked, gasketed. weatherstripped or otherwise sealed, /
<br />JOINTS & CRACKS
<br />SOLE & TOP 903.2 Sole plates and penetrations through top plates of exterior walls must be sealed. V
<br />PLATES
<br />INFILTRATION 903,2 Infiltration barrier must be installed in exterior walls & raised wood floors, V
<br />BARRIER
<br />INTERIOR 903,2 All openings in interior surfaces of ceilings and exterior walls must be sealed, V
<br />JOINTS/CRACKS
<br />FIREPLACES 903,2 Fireplaces must have flue dampers, glass doors and outside combustion air intakes,
<br />EXHAUST FANS 903.2 Exhaust fans vented to unconditioned space shall have dampers, except for combustion
<br /> devices with integral exhaust ductwork.
<br />WATER HEATERS 904,2 Comply with efficiency requirements in Table 9-7A, Switch or clearly marked circuit break~(electric)
<br /> or cutoff (gas) must be provided, External or built-in heat trap required,
<br />SWIMMING 904.3 Spas & heated pools must have covers (except solar heated), Non-commercial pools must have a
<br />POOLS & SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 78%,
<br />HOT WATER 904.4 Insulation is required only for recirculating systems, including heat recove~nits, In such cases,
<br />PIPES piping heat loss shall be limited to a maximum of 17,5 BTUH per linear foot of pipe.
<br />SHOWER HEADS 904,5 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG.
<br />HVAC DUCT 904,6 All duels, fittings, mechanical equipment and plenum chambers shall be mechanically attached,
<br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904,6, Ducts in unconditioned v"
<br />INSULATION & space and air handlers located in attics must be insulated to a minimum R-4,2 (R-6 after 1/1/92),
<br />INST ALLA TION
<br />HV AC CONTROLS 904,7 Separate readily accessible manual or automatic thermostat for each system,
<br />RENOVATIONS 1003,0 Meets the requirements of see, 1003,0, See step 3 of page 2 of this form.
<br />ONLY GLASS
<br />
<br />-1 -
<br />
|