Laserfiche WebLink
<br />FORM 1000-C.91 <br />SMALL ADDITIONS <br />AND RENOVATIONS <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 10 - Residential Prescriptive Compliance Method <br />Department of Community Affairs <br /> <br />Climate Zones <br />CENTRAL 4 5 6 <br /> <br />COMPLIANCE WITH SECTION 10 OF THE FLORIDA ENERGY EFFICIENCY CODE MAY BE DEMONSTRATED BY USE OF FORM 1 OOOC-91 FOR ADDITIONS OF 600 SOLARE FEET OR LESS. AND RENOVATIONS <br />TO SINGLE AND MULTIFAMILY RESIDENCES. ALTERNATIVE METHODS ARE PROVIDED FOR ADDITIONS BY US FORM 1000A-91 or A-91 <br /> <br />BUILDER: <br /> <br />RENOVATION <br />ADDITION <br />MULTIFAMILY ATTACHED D <br />SINGLE-FAMILY DETACHED D <br /> <br /> <br />5060 <br />~ <br /> <br />PROJECT NAIIE <br />AND ADDRESS: 2. <br /> <br />OWNER: ~ <br /> <br />FOR ADDITIONS ONLY: <br /> <br />PERCENTAGE <br />OF GLASS <br />TO FLOOR <br /> <br />UNDER ATTIC: <br /> <br />R c <br />SINGLE ASSEMBLY <br />R = <br /> <br />GJ(j, D <br />ITJ,D <br />Ro ITJ,D <br /> <br />NEW GLASS AREA AND TYPE <br />CLEAR T1NUILM,SOLAR SCREEN <br />SO SINGLE- ITIIJ SO <br />FT PANE FT <br />SO DOUBLE- ITIIJ SO <br />FT PANE FT <br />FLOOR TYPE AND INSULATION <br />WOOD MASONRY <br />RAISE~ ~ ITJ. D RAISE~ = DJ.D <br /> <br />COM~O~ ITJ. 0 COMMRO~ []] <br /> <br />SLAB-ON- _ IT] V1 <br />GRADE. R - ,~ <br /> <br />IF MULTIFAMILY, NUMBER OF <br />UNITS COVERED BY <br />THIS SUBMITTAL ITIJ <br /> <br />CONDITIONED ' <br />FLOOR AREA <br />PREDOMINANT <br />EAVE OVERHANG <br />LENGTH <br />PORCH OVERHANG <br />LENGTH <br /> <br />URJ% <br /> <br />WALL TYPE AND INSULATION <br />WOOD FRAME MASONRY <br />EXTER~O~ CD. D EXTE~O~ [RJ.D <br />ADJAC:~ CD. D ADJA~E~T CD. D <br />COMMO~ CD D COMMO~: rn <br />R , R . <br /> <br />CEILING TYPE AND INSULATION <br /> <br />COMMON: <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HOT WATER SYSTEM <br />IN ~. CENTRAL D NONE D ELECTRIC STRIP D HEAT PUMP D ELECTRIC D SOLAR <br />UNCONDITIONED D D D NATURAL GAS D HEAT RECOVERY <br />SPACE: R = ROOM NATURAL GAS ROOM/PTHP <br />rnJ. [(j D PTAC D OTHER FUELS D NONE D OTHER FUELS D OED HEAT PUMP <br />IN CONDITIONED D NO NEW SYSTEM D NO NEW SYSTEM D NO NEW .f} SF/EF 0 D.ITJ <br />SPACE: R 0 ~.~ COPIHSPFIAFUE = DrT-~ SYSTEM EF = <br />ITJ,D SEERI EER = NUMBER OF BEDROOMS - rn <br /> <br /> <br />ReView of plans and speCIfications co~ered by this calculation Indicates compliance with <br />the Flonda Energy Code. Before constr ction is completed. this bUilding will be inspected <br />for compliance In aCCO~d~n Ith Ion 553.908. F.S. ~ <br /> <br />BUILDING OFFICIAL' ________ <br /> <br />), - tf - cr &- <br /> <br />DATE <br /> <br />I hereby certify that the plans and specifications covered by the calculation are In compliance With the <br />Florida Energy Code. <br /> <br />TABLE 10A[ MINIMUM REQUIREMENTS FOR ALL PACKAGES <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904.1 Minimum of 0.34 CFM per linear foot of operable sash crack (includes sliding glass doors). ~ <br />EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. ft. of door area: solid core, wood panel, insulated or glass doors only. 'I. <br />ADJACENT DOORS <br />EXTERIOR 904.1 To be caulked, gasketed, weatherstripped or otherwise sealed. -/... <br />JOINTS & CRACKS <br />SOLE & TOP 903.2 Sole plates and penetrations through top plates of exterior walls must be sealed. ~ <br />PLATES <br />INFilTRATION 903.2 Infiltration barrier must be installed in exterior walls & raised wood floors. 'f <br />BARRIER <br />INTERIOR 903.2 All openings in interior surfaces of ceilings and exterior walls must be sealed. '1-. <br />JOINTS/CRACKS <br />FIREPLACES 903.2 Fireplaces must have flue dampers, glass doors and outside combustion air intakes. A)1f <br />EXHAUST FANS 903.2 Exhaust fans vented to uncondi1ioned space shall have dampers, except for combustion JM <br /> devices with integral exhaust ductwork. <br />WATER HEATERS 904.2 Comply with efficiency requirements in Table 9-7A. Switch or clearly marked circuit breaker (electric) iliA <br /> or cutoff (gas) must be provided. External or built-in heat trap required. <br />SWIMMING 904.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a Nfl <br />POOLS & SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 78%. <br />HOT WATER 904.4 Insulation is required only for recirculating systems, including heat recovery units. 111 such cases, AlIi <br />PIPES piping heat loss shall be limited 10 a maximum of 17.5 BTUH per linear foot of pipe. <br />SHOWER HEADS 904.5 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG. AlP <br />HVAC DUCT 904.6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, IA <br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned <br />INSULATION & space and air handlers located in attics must be insulated to a minimum R-4.2 (R-6 after 1/1/92). <br />INSTALLATION <br />HV AC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system. I' <br />RENOVATIONS 1003.0 Meets the requirements of sec. 1003.0. See step 3 of page 2 of this form. 'I,. <br />ONLY GLASS <br /> <br />-1 - <br />