<br />FLORIDA ENERGY EFFICIENCY CODE
<br />
<br />FOR BUILDING CONSTRUCTION
<br />
<br />FORM 1000.A.89 SECTION 10 - RESIDENTIAL PRESCRIPTIVE COMPLIANCE METHOD CLIMATE Z NES
<br />DEPARTMENT OF COMMUNITY AFFAIRS CENTRA 5 6
<br />
<br />COMPLIANCE WITH SECTION 10 OF THE FLORIDA ENERGY EFFICIENCY CODE MAY BE DEMONSTRATED BY USE OF FORM 1000A-89 FOR SINGLE AND MULTIFAMILY RESIDENCES OF 3 STORIES OR LESS
<br />IN HEIGHT, AND ADDITIONS TO EXISTING RESIDENTIAL BUILDINGS TO COMPLY, A BUILDING MUST MEET OR EXCEED ALL OF THE ENERGY EFFICIENCY PRESCRIPTIVES IN ANY ONE OF THE
<br />PRESCRIPTIVE COMPONENT PACKAGES AND COMPLY WITH THE PRESCRIPTIVE MEASURES LISTED IN TABLE 10A OF THIS FORM, COMPLIANCE BY THIS METHOD WILL BE, IN MOST CASES,
<br />EQUIVALENT TO AN EPI OF 100 POINTS OR LESS, AN ALTERNATIVE METHOD IS PROVIDED FOR ADDITIONS OF 600 SQUARE FEET OR LESS BY USE OF FORM 1000C-89 IF A BUILDING DOES NOT
<br />COMPLY WITH THIS METHOD, IT MAY STILL COMPLY UNDER SECTION 9 OF THE CODE.
<br />
<br />
<br />OWNER:
<br />
<br />~.s8
<br />4ff.6D
<br />~
<br />
<br />NEW CONSTRUCTION !5{1'
<br />
<br />ADDITION 0
<br />
<br />MULTIFAMILY ATTACHED 0
<br />(3 stories or less)
<br />SINGLE-FAMILY DETACHED 0
<br />
<br />IF MULTIFAMILY, NUMBER OF
<br />UNITS COVERED "BY [IJ]
<br />THIS SUBMITTAL
<br />
<br />CHECK IF THIS SUBMITTAL
<br />8EPRESENTS A WORST CASE
<br />CONDITION 0
<br />
<br />CONDITIONED ~ SO
<br />FLOOR AREA ~ FT
<br />PREDOMINANT rn [g
<br />EAVE OVERHANG 30FT
<br />LENGTH .
<br />PORCH OVERHANG m 0
<br />LENGTH . FT
<br />
<br />CLEAR
<br />SINGLE- DJI] SO
<br />PANE FT
<br />DOUBLE- ~5~SO
<br />PANE ~J FT
<br />
<br />GLASS AREA AND TYPE
<br />TINT,FILM.SOLAR SCREEN
<br />
<br />SINGLE- ITIIJ SO
<br />PAN E FT
<br />DOUBLE- ITIIJ SO
<br />PANE FT
<br />
<br />PERCENTAGE
<br />OF GLASS I.lQl
<br />TO FLOOR L!l1J %
<br />
<br />WALL TYPE AND INSULATION
<br />WOOD FRAME MASONRY
<br />EXTER~O~ rn. D EXTE~O~ [E].[Q]
<br />ADJACi~ rn . D ADJA~E~ m.o
<br />COMMRO~ rn. D COM~O~ m.o
<br />
<br />FLOOR TYPE AND INSULATION
<br />WOOD MASONRY
<br />RAISE~ = [I] D RAISE~ = DJ.D
<br />COM~O~ [D. D COM~O~ CDO
<br />SLAB-ON- IT:] 0
<br />GFIADE: R = ~.lQJ
<br />
<br />HOT WATER SYSTEM
<br />
<br />CEILING TYPE AND INSULATION
<br />
<br />COMPLIANCE 0
<br />PACKAGE
<br />CHOSEN
<br />
<br />UNDER ATTI~o ~.[a
<br />
<br />
<br />COMMON R= m.o
<br />
<br />DUCTS
<br />IN
<br />UNCONDITIONED
<br />SPACE R =
<br />
<br />illl [9
<br />
<br />IN CONDITIONED
<br />SPACE: R =
<br />
<br />m.o
<br />
<br />COOLING SYSTEM
<br />
<br />~ CENTRAL 0 NONE
<br />
<br />o ROOM
<br />
<br />o PACKAGED TERMINAL
<br />AIR CONDITIONER
<br />
<br />[ili] .~
<br />
<br />HEATING SYSTEM
<br />
<br />o ELECTRIC STRIP rxJ HEAT PUMP
<br />o NATURAL GAS 0 OTHER FUELS
<br />o ROOM UNIT OR 0 NONE
<br />PACKAGED TERMINAL
<br />HEAT PUMP
<br />
<br />COP/HSPF/AFUE = ~.~j
<br />
<br />~ ELECTRIC D NONE
<br />o NATURAL GAS
<br />o OTHER FUELS
<br />
<br />EF= .~
<br />
<br />SEERI EER =
<br />
<br />
<br />NUMBER OF BEDROOMS =
<br />
<br />o SOLAR
<br />1KI HEAT RECOVERY
<br />o DEDICATED HEAT PUMP
<br />
<br />SF/EF = ~.~
<br />rn
<br />
<br />Review of the plans and specifications covered by this calculation indicates
<br />compliance with the Florida Ene Code, Before constructio is completed, this
<br />building will be inspected fo Ii in accordance wi! e ion 553.908 F,S.
<br />BUILDING OFFICIAL:
<br />DATE:
<br />
<br />In accordance with Section 55
<br />and specifications covere~l:lithi
<br />Florida Energy Code, /
<br />
<br />OWNER/AGENT:
<br />
<br />DATE:
<br />
<br />
<br />TABLE 10A MINIMUM REQUIREMENTS FOR ALL PACKAGES
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />WINDOWS 904,1 MAXIMUM OF 0,5 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK. ..-
<br />EXTERIOR & ADJACENT DOORS 904,1 SOLID CORE, WOOD PANEL, INSULATED OR GLASS DOORS ONLY, MAXIMUM OF 0,5 CFM PER SQUARE FOOT OF DOOR AREA.
<br />INCLUDES SLIDING ~LASS DOORS, v
<br />EXTERIOR JOINTS/CRACKS 904,1 TO BE CAULKED GASKETED WEATHERSTRIPPED OR OTHERWISE SEALED, V
<br />SOLE & TOP PLATES 903.2 SOLE PLATES AND PENETRATIONS THROUGH TOP PLATES OF EXTERIOR WALLS MUST BE SI:ALED, v
<br />INFILTRATION BARRIER 903,2 INFILTRATION BARRIER MUST BE INSTALLED IN EXTERIOR WALLS & RAISED WOOD FLOORS, V
<br />INTERIOR JOINTS/CRACKS 903,2 ALL OPENINGS IN INTERIOR SURFACES OF CEILINGS AND EXTERIOR WALLS MUST BE SEALED, V
<br />FIREPLACES 903,2 FIREPLACES MUST HAVE FLUE DAMPERS GLASS DOORS AND OUTSIDE COMBUSTION AIR INTAKES.
<br />EXHAUST FANS 903,2 EXHAUST FANS VENTED TO UNCONDITIONED SPACE SHALL HAVE DAMPERS, EXCEPT FOR COMBUSTION DEVICES WITH v'
<br />INTEGRAL EXHAUST DUCTWORK,
<br /> MUST BEAR LABEL INDICATING COMPLIANCE WITH ASH RAE STANDARD 90 OR COMPLY WITH EFFICIENCY AND STANDBY
<br />WATER HEATERS 904,2 LOSS REQUIREMENTS, SWITCH OR CLEARLY MARKED CIRCUIT BREAKER (ELECTRIC) OR CUT-OFF (GAS) VALVE MUST BE ./
<br /> PROVIDED, AN EXTERNAL OR BUILT-IN HEAT TRAP MUST BE PROVIDED.
<br />SPAS AND HEATED 904,3 SPAS AND HEATED POOLS MUST HAVE COVERS (EXCEPT SOLAR HEATED). NON-GOMMERCIAL POOLS MUST HAVE A
<br />SWIMMING POOLS PUMP TIMER, GAS SPA & POOL HEATERS MUST HAVE MINIMUM THERMAL EFFICIENCY OF 7!i%. ,/
<br />HOT WATER PIPES 904.4 INSULATION IS REQUIRED ONLY FOR RECIRCULATING SYSTEMS INCLUDING HEAT RECOVERY UNITS, IN SUCH
<br />CASES, PIPING HEAT LOSS SHALL BE LIMITED TO A MAXIMUM OF 17,5 BTUH PER L11\JEAR FOOT OF PIPE, ,/
<br />SHOWER HEADS 904,5 WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS PER MINUTE AT 80 PSIG, V
<br />HVAC DUCT 903,2 CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS AND LOCAL MECHNICAL CODE. JOINTS IN UNCONDITIONED //
<br />CONSTRUCTION 904,6 SPACE SHALL BE SEALED, DUCTS SHALL BE INSULATED TO A MINIMUM OF R-4.2.
<br />HVAC CONTROLS ~O47 A SEPARATE. READILY ACCESSIBLE MANUAL OR AUTOMATIC THERMOSTAT FOR EACH SYSTEM, ;/