Laserfiche WebLink
<br />.. '. .. <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br /> <br />FOR BUILDING CONSTRUCTION <br /> <br />FORM 1000.A.89 SECTION 10 - RESIDENTIAL PRESCRIPTIVE COMPLIANCE METHOD CLIMATE Z NES <br />DEPARTMENT OF COMMUNITY AFFAIRS CENTRA 5 6 <br /> <br />COMPLIANCE WITH SECTION 10 OF THE FLORIDA ENERGY EFFICIENCY CODE MAY BE DEMONSTRATED BY USE OF FORM 1000A-89 FOR SINGLE AND MULTIFAMILY RESIDENCES OF 3 STORIES OR LESS <br />IN HEIGHT, AND ADDITIONS TO EXISTING RESIDENTIAL BUILDINGS TO COMPLY, A BUILDING MUST MEET OR EXCEED ALL OF THE ENERGY EFFICIENCY PRESCRIPTIVES IN ANY ONE OF THE <br />PRESCRIPTIVE COMPONENT PACKAGES AND COMPLY WITH THE PRESCRIPTIVE MEASURES LISTED IN TABLE 10A OF THIS FORM, COMPLIANCE BY THIS METHOD WILL BE, IN MOST CASES, <br />EQUIVALENT TO AN EPI OF 100 POINTS OR LESS, AN ALTERNATIVE METHOD IS PROVIDED FOR ADDITIONS OF 600 SQUARE FEET OR LESS BY USE OF FORM 1000C-89 IF A BUILDING DOES NOT <br />COMPLY WITH THIS METHOD, IT MAY STILL COMPLY UNDER SECTION 9 OF THE CODE. <br /> <br /> <br />OWNER: <br /> <br />~.s8 <br />4ff.6D <br />~ <br /> <br />NEW CONSTRUCTION !5{1' <br /> <br />ADDITION 0 <br /> <br />MULTIFAMILY ATTACHED 0 <br />(3 stories or less) <br />SINGLE-FAMILY DETACHED 0 <br /> <br />IF MULTIFAMILY, NUMBER OF <br />UNITS COVERED "BY [IJ] <br />THIS SUBMITTAL <br /> <br />CHECK IF THIS SUBMITTAL <br />8EPRESENTS A WORST CASE <br />CONDITION 0 <br /> <br />CONDITIONED ~ SO <br />FLOOR AREA ~ FT <br />PREDOMINANT rn [g <br />EAVE OVERHANG 30FT <br />LENGTH . <br />PORCH OVERHANG m 0 <br />LENGTH . FT <br /> <br />CLEAR <br />SINGLE- DJI] SO <br />PANE FT <br />DOUBLE- ~5~SO <br />PANE ~J FT <br /> <br />GLASS AREA AND TYPE <br />TINT,FILM.SOLAR SCREEN <br /> <br />SINGLE- ITIIJ SO <br />PAN E FT <br />DOUBLE- ITIIJ SO <br />PANE FT <br /> <br />PERCENTAGE <br />OF GLASS I.lQl <br />TO FLOOR L!l1J % <br /> <br />WALL TYPE AND INSULATION <br />WOOD FRAME MASONRY <br />EXTER~O~ rn. D EXTE~O~ [E].[Q] <br />ADJACi~ rn . D ADJA~E~ m.o <br />COMMRO~ rn. D COM~O~ m.o <br /> <br />FLOOR TYPE AND INSULATION <br />WOOD MASONRY <br />RAISE~ = [I] D RAISE~ = DJ.D <br />COM~O~ [D. D COM~O~ CDO <br />SLAB-ON- IT:] 0 <br />GFIADE: R = ~.lQJ <br /> <br />HOT WATER SYSTEM <br /> <br />CEILING TYPE AND INSULATION <br /> <br />COMPLIANCE 0 <br />PACKAGE <br />CHOSEN <br /> <br />UNDER ATTI~o ~.[a <br /> <br /> <br />COMMON R= m.o <br /> <br />DUCTS <br />IN <br />UNCONDITIONED <br />SPACE R = <br /> <br />illl [9 <br /> <br />IN CONDITIONED <br />SPACE: R = <br /> <br />m.o <br /> <br />COOLING SYSTEM <br /> <br />~ CENTRAL 0 NONE <br /> <br />o ROOM <br /> <br />o PACKAGED TERMINAL <br />AIR CONDITIONER <br /> <br />[ili] .~ <br /> <br />HEATING SYSTEM <br /> <br />o ELECTRIC STRIP rxJ HEAT PUMP <br />o NATURAL GAS 0 OTHER FUELS <br />o ROOM UNIT OR 0 NONE <br />PACKAGED TERMINAL <br />HEAT PUMP <br /> <br />COP/HSPF/AFUE = ~.~j <br /> <br />~ ELECTRIC D NONE <br />o NATURAL GAS <br />o OTHER FUELS <br /> <br />EF= .~ <br /> <br />SEERI EER = <br /> <br /> <br />NUMBER OF BEDROOMS = <br /> <br />o SOLAR <br />1KI HEAT RECOVERY <br />o DEDICATED HEAT PUMP <br /> <br />SF/EF = ~.~ <br />rn <br /> <br />Review of the plans and specifications covered by this calculation indicates <br />compliance with the Florida Ene Code, Before constructio is completed, this <br />building will be inspected fo Ii in accordance wi! e ion 553.908 F,S. <br />BUILDING OFFICIAL: <br />DATE: <br /> <br />In accordance with Section 55 <br />and specifications covere~l:lithi <br />Florida Energy Code, / <br /> <br />OWNER/AGENT: <br /> <br />DATE: <br /> <br /> <br />TABLE 10A MINIMUM REQUIREMENTS FOR ALL PACKAGES <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904,1 MAXIMUM OF 0,5 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK. ..- <br />EXTERIOR & ADJACENT DOORS 904,1 SOLID CORE, WOOD PANEL, INSULATED OR GLASS DOORS ONLY, MAXIMUM OF 0,5 CFM PER SQUARE FOOT OF DOOR AREA. <br />INCLUDES SLIDING ~LASS DOORS, v <br />EXTERIOR JOINTS/CRACKS 904,1 TO BE CAULKED GASKETED WEATHERSTRIPPED OR OTHERWISE SEALED, V <br />SOLE & TOP PLATES 903.2 SOLE PLATES AND PENETRATIONS THROUGH TOP PLATES OF EXTERIOR WALLS MUST BE SI:ALED, v <br />INFILTRATION BARRIER 903,2 INFILTRATION BARRIER MUST BE INSTALLED IN EXTERIOR WALLS & RAISED WOOD FLOORS, V <br />INTERIOR JOINTS/CRACKS 903,2 ALL OPENINGS IN INTERIOR SURFACES OF CEILINGS AND EXTERIOR WALLS MUST BE SEALED, V <br />FIREPLACES 903,2 FIREPLACES MUST HAVE FLUE DAMPERS GLASS DOORS AND OUTSIDE COMBUSTION AIR INTAKES. <br />EXHAUST FANS 903,2 EXHAUST FANS VENTED TO UNCONDITIONED SPACE SHALL HAVE DAMPERS, EXCEPT FOR COMBUSTION DEVICES WITH v' <br />INTEGRAL EXHAUST DUCTWORK, <br /> MUST BEAR LABEL INDICATING COMPLIANCE WITH ASH RAE STANDARD 90 OR COMPLY WITH EFFICIENCY AND STANDBY <br />WATER HEATERS 904,2 LOSS REQUIREMENTS, SWITCH OR CLEARLY MARKED CIRCUIT BREAKER (ELECTRIC) OR CUT-OFF (GAS) VALVE MUST BE ./ <br /> PROVIDED, AN EXTERNAL OR BUILT-IN HEAT TRAP MUST BE PROVIDED. <br />SPAS AND HEATED 904,3 SPAS AND HEATED POOLS MUST HAVE COVERS (EXCEPT SOLAR HEATED). NON-GOMMERCIAL POOLS MUST HAVE A <br />SWIMMING POOLS PUMP TIMER, GAS SPA & POOL HEATERS MUST HAVE MINIMUM THERMAL EFFICIENCY OF 7!i%. ,/ <br />HOT WATER PIPES 904.4 INSULATION IS REQUIRED ONLY FOR RECIRCULATING SYSTEMS INCLUDING HEAT RECOVERY UNITS, IN SUCH <br />CASES, PIPING HEAT LOSS SHALL BE LIMITED TO A MAXIMUM OF 17,5 BTUH PER L11\JEAR FOOT OF PIPE, ,/ <br />SHOWER HEADS 904,5 WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS PER MINUTE AT 80 PSIG, V <br />HVAC DUCT 903,2 CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS AND LOCAL MECHNICAL CODE. JOINTS IN UNCONDITIONED // <br />CONSTRUCTION 904,6 SPACE SHALL BE SEALED, DUCTS SHALL BE INSULATED TO A MINIMUM OF R-4.2. <br />HVAC CONTROLS ~O47 A SEPARATE. READILY ACCESSIBLE MANUAL OR AUTOMATIC THERMOSTAT FOR EACH SYSTEM, ;/ <br />