Laserfiche WebLink
<br />FORM 1000-C-91 <br />SMALL ADDITIONS <br />AND RENOVATIONS <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 10 - Residential Prescriptive Compliance Method <br />Department of Community Affairs <br /> <br />Climate Zones <br />CENTRAL~5 6 <br /> <br />COMPLIANCE WITH SECTION 10 OF THE FLORIDA ENERGY EFFICIENCY CODE MAY BE DEMONSTRATED BY USE OF FORM 1 OOOC-91 FOR ADDITIONS OF 600 SQUARE FEET OR LESS. AND RENOVATIONS <br />TO SINGLE AND MULTIFAMILY RESIDENCES. ALTERNATIVE METHODS ARE PROVIDED FOR ADDITIONS BY USE OF FORM1000A-91 or900A-91 <br /> <br /> <br />PROJECT NAME <br />AND ADDRESS: <br /> <br /> <br />RENOVATION <br />ADDITION <br /> <br />IF MULTIFAMILY. NUMBER OF <br />UNITS COVERED BY <br />THIS SUBMITTAL. IT]] <br /> <br />CONDITIONED ~8 (;, SO <br />FLOOR AREA ~ FT <br />PREDOMINANT rn [Q <br />EAVE OVERHANG '-' FT <br />LENGTH . <br />PORCH OVERHANG m 0 <br />LENGTH . FT <br /> <br />SINGLE- <br />PANE <br /> <br />DDUBLE- <br />PANE <br /> <br />CLIMATE <br />E: <br />JURISDICTION <br />NO,: <br /> <br />NEW GLASS AREA AND TYPE <br />CLEAR TlNTFILM,SOLAR SCREEN <br /> <br />DID SO SINGLE- ~ SO <br />FT PANE ~ FT <br />DID SO DOUBLE- DID so <br />FT PANE FT <br /> <br />MULTIFAMILY ATTACHED <br />SINGLE-FAMILY DETACHED 0 <br /> <br /> WALL TYPE AND INSULATION CEILING TYPE AND INSULATION FLOOR TYPE AND INSULATION <br />FOR ADDITIONS ONLY: WOOD FRAME MASONRY UNDER ATTIC: ~.~ WOOD MASONRY <br /> PERCENTAGE EXTER~O~ OJ. D EXTE~O~ rn.~ Rc RAISE~ = [[1 D RAISED _ rn 0 <br /> OF GLASS R - . <br /> TO FLOOR ADJAC~~ OJ. D ADJA~E~T ITJ.O SINGLE ASSEMBLY m.o COM~O~ [[I 0 COMMRO~ ffiO <br /> R = <br /> [lIJ% COMMRO~ OJ. D COM~O~: m.o COMMON: m.D SLAB-ON- ~ [g <br /> Ro GRADE: R = . <br />DUCTS COOLING SYSTEM HEATING SYSTEM HOT WATER SYSTEM <br /> -~---- <br />IN ~ CENTRAL 0 NONE D ELECTRIC STRIP gj HEAT PUMP g] ELECTRIC D SOLAR <br />UNCONDITIONED <br />SPACE: R 0 D ROOM D NATURAL GAS D ROOM/PTHP D NATURAL GAS D HEAT RECOVERY <br />m.D D PTAC D OTHER FUELS D NONE D OTHER FUELS D OED. HEAT PUMP <br />IN CONDITIONED D NO NEW SYSTEM o NO NEW SYSTEM D NO NEW . IT] SF/EF 0 o.rn <br />SPACE: R 0 rn.~ COPIHSPFIAFUE = OJ TJ SYSTEM EF c <br />ITJ.O SEER/EER 0 rn <br /> NUMBER OF BEDROOMS = <br /> <br />I hereby certify that the plans and specifications covered by the calculation are in compliance With the ReView of plans and speCifications covered by this calculation indicates compliance With <br />Florida Energy COde~ <!:' _ the Flonda Energy cOd~~nstruction IS completed this building will be Inspected <br />PREPARED BY '( ~ -,,::\Ie DATE for comphance In accordanc h sectl~;'8. F.S ^ L <br />I hereby certify that ~~s In ~ the Florida Energy Code BUILDING OFFICIAL, '../ /1/1_A ..< 4..~ ~_ <br />OWNER AGENT: / '" -L. 0 DATE DATE .3.. /0 ~ 9 2.-- <br /> I <br />TABLE 10AI MINIMUM AEQUIREMENTS FOR ALL PACKAGES <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904.1 Minimum of 0.34 CFM per linear foot of operable sash crack (includes sliding glass doors). <br />EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. ft. of door area: solid core, wood panel, insulated or glass doors only. <br />ADJACENT DOORS <br />EXTERIOR 904.1 To be caulked, gasketed, weatherstripped or otherwise sealed. <br />JOINTS & CRACKS <br />SOLE & TOP 903.2 Sole plates and pene1rations through top plates of exterior walls must be sealed. <br />PLATES <br />INFILTRATION 903.2 Infiltration barrier must be installed in exterior walls & raised wood floors. <br />BARRIER <br />INTERIOR 903.2 All openings in interior surfaces of ceilings and exterior walls must be sealed. <br />JOINTS/CRACKS <br />FIREPLACES 903,2 Fireplaces must have flue dampers, glass doors and outside combustion air intakes, <br />EXHAUST FANS 903.2 Exhaust fans vented to unconditioned space shall have dampers, excep1 for combustion <br /> devices with integral exhaust ductwork, <br />WATER HEATERS 904.2 Comply with efficiency requirements in Table 9-7A. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (gas) must be provided, External or built-in heat trap required, <br />SWIMMING 904_3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a <br />POOLS & SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 7B%. <br />HOT WATER 904-4 Insulation is required only for recirculating systems, including heat recovery units. In such cases, <br />PIPES piping heat loss shall be limited to a maximum of 17.5 BTUH per linear foot of pipe, <br />SHOWER HEADS 904_5 Water flow mus1 be restricted to no more than 3 gallons per minute at 80 PSIG. <br />HVAC DUCT 904.6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned <br />INSULATION & space and air handlers located in attics must be insulated to a minimum R-4.2 (R-Ei after 1/1/92), <br />INST ALLA TION <br />HVAC CONTROLS 904_7 Separate readily accessible manual or automatic thermostat for each system. <br />RENOVATIONS 1003.0 Meets the requirements of see, 1003,0. See step 3 of page 2 of this form. <br />ONLY GLASS <br /> <br />-1 - <br />