<br />FORM 900-A-91 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 9 - Residential Point System Method <br />Department of Community Affairs <br /> <br />Climate Zones <br />CENTRALllS 6 <br /> <br /> <br />OWNER: <br /> <br />BUILDER: <br />PERMITTING <br />OFFICE: <br /> <br />PERMI <br />NO,: <br /> <br /> <br />GLASS AREA AND TYPE <br /> <br />CLEAR TINT,FILM,SOLAR SCREEN <br /> <br />SINGLE- ITIIJ sa. SINGLE- ~I r... sa. <br />~E IT ~E ~IT <br /> <br />DOUBLE- ITIIJ sa. DOUBLE- ITIIJ sa. <br />PANE IT PANE FT. <br /> <br />NEW CONSTRUCTION ~ <br /> <br />ADDITION D <br /> <br />MULTIFAMILY ATTACHED D <br /> <br />SINGLE-FAMILY DETACHED ~ <br /> <br />IF MULTIFAMILY, NUMBER OF CONDITIONED ~I ::t.., 7 sa. <br />UNITS COVERED BY OJ] FLOOR AREA ~ FT. <br />THIS SUBMITTAL PREDOMINANT em ~ <br />EAVE OVERHANG <br />CHECK IF THIS SUBMITTAL LENGTH Z, FT. <br />REPRESENTS A WORST CASE PORCH OVERHANG nI n <br />CONDITION: ~ LENGTH ~. ~ IT <br /> <br /> NET WALL AREA AND INSULATION <br />EXTERIOR MASONRY R - EXTERIOR FRAME R _ EXTERIOR STEEL R - EXTERIOR LOG R - <br />CIIIDso. rn,D ~so rn CIIID SO rn [IIIIJ ~~.' rn <br /> FT FT. FT <br />ADJACENT MASONRY R - ADJACENT FRAME R = ADJACENT STEEL R - ADJACENT LOG R - <br />CIIID SO rn,D 0JJJill ~~. [ill] CIIID SO rn [IIIIJ SO rn <br /> IT FT FT <br /> <br /> CEILING AREA AND INSULATION FLOOR TYPE AND INSULATION <br />UNDER ATTIC R= SINGLE ASSEMBLY R= SLAB PERIMETER R= RAISED WD 0 CON 0 R= <br />~SQ. [ili] CIIIDSQ. rn D::iliEJ FT. rn CIIIDSQ. rn <br />IT FT. IT <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HVAC CREDITS HOT WATER SYSTEM HOT WATER CREDITS <br />IN IB CENTRAL o ELECTRIC STRIP ~ HEAT ~ CEILING FANS ~ ELECTRIC SOLAR: D rn <br />UNCONDITIONED <br />SPACE R = o ROOM o NATURAL GAS PUMP ~ CROSS VENTILATION o NATURAL GAS SF. = , <br />HEAT RECOVERY ICHECK! B <br />rn.~ o PACKAGE TERMINAL o ROOM UNIT OR o OTHER o WHOLE HOUSE FAN D OTHER FLiELS <br />FUELS DEDICATED <br />IN CONDITIONED AIR CONDITIONER PACKAGE TERMINAL o NONE o AntC RADIANT o NONE HEAT PUMP: D,rn <br />SPACE R = o NONE HEAT PUMP BARRIER E.F = <br />rn,o SEER/EER = rn,~ COP I HSPF I ~,~ o MULTIZONE EF = ,~~ NUMBER OF rn <br />AFUE = BEDROOMS = <br /> <br />INFIL TRA TION CIlJiliEliJ DiliIili@ [TI0,~ <br />PRACTICE USED X 100 = <br />D #1 ,g] #2 D #3 TOTAL AS-BUILT POINTS TOTAL BASE POINTS CALCULATED E,P.I. <br />CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS. <br /> <br />I hereby certify that the plans and specifications covered by the calculation are in compliance with the <br />Florida Energy Code./? c: <br /> <br />PREPARED BY: ~~.1. ~ -- -'" DATE: '1-(6 -9'-~ <br /> <br />I hereby certify that this building is in compliance with the Florida Energy Code. <br /> <br />Review of plans and specifications covered by this calculation indicates compliance with <br />the Florida Energy Code. Before construction is completed, this building will be inspected <br />for compliance in accordance Section 5 8, F.S. <br /> <br />OWNER AGENT: <br /> <br />DATE: <br /> <br /> <br />DATE: <br /> <br /> <br />9A I PRESCRIPTIVE MEASURES (must be met or exceeded by all residences,) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904,1 Maximum of 0,34 CFM per linear foot of operable sash crack (includes sliding glass doors), <br />EXTERIOR & 904,1 Maximum of 0,5 CFM per sq, It, of door area: solid core, wood panel, insulated or glass doors only. <br />ADJACENT DOORS <br />EXTERIOR JOINTS 904.1 To be caulked, gasketed, weatherstripped or otherwise sealed. <br />& CRACKS <br />WATER HEATERS 904.2 Comply with efficiency requirements in Table 9-7A. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (gas) must be provided, External or built-in heat trap required, <br />SWIMMING POOLS 904,3 Spas & heated pools must have covers (except solar heated), Non-commercial pools must have a <br />& SPAS pump timer, Gas spa & pool heaters must have minimum thermal efficiency of 78%, <br />SHOWER HEADS 904,5 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG, <br />HV AC DUCT 904,6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904,6. Ducts in unconditioned <br />INSULATION space and air handlers located in attics must be insulated to a minimum R-4,2 (R-6 alter 1/1/92). <br />& INSTALLATION <br />HVAC CONTROLS 904,7 Separate readily accessible manual or automatic thermostat for each system, <br />INSULATION 904,9 Ceilings-Min, R-19. Common Walls-Frame R-11 or CBS R-3. Common Ceilings & Floors R-11. <br /> <br />- 1 - <br />