<br />91 HEATING SYSTEM Ml:JLTIPLlERS (HSM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />SYSTEM TYPE' . HEATING SYSTEM MULTIPLIERS <br />Central Heat HSPF 6.4 . 6.79 6.8 . 6.89 6.9.7.39 7.4.7.89 7.9 . 8.39 8.4 . 8,89 8.9 . 9.39 9.4 . 9.89 <br />Pump Units HSM .53 .50 .49 .46 .43 .41 .38 .36 <br /> HSPF 9.9. 10.39 10.4.10.89 10.9.11.39 11.4-11.89 11.9.12.39 12.4 & Uo <br /> HSM .34 .33 .31 .30 .29 .28 <br />PTHP COP 2.6 . 2.69 2.7.2.89 2.9 . 3.09 3.10.3.29 3.30 . 3.49 3.50 . 3.69 3.70. 3.89 3.90.4.19 <br /> HSM .38 .37 .34 .32 .30 .29 .27 .26 <br />Electric Strip 1.0 <br />Gas & Other Fuels 1.0 (See Table 9J for Credit Multiplier) <br />f-i991 Minimums: Central Units-Air Source 6.4 HSPF. Water Source 3.4 COP. Ground Water Source 3.2 COP. PTHP 2.6 COP. <br />1992 Minimums: Central Units-Air Source 6.8 HSPF. Water Source 3.8 COP. Ground Water Source 3.4 COP. PTHP 2.7 COP. <br />HSPF means HealmQ Seasonal Pertormance Factor COP means Coefficltmt of Pertormance. <br /> <br />9J HEATING CREDIT MULTIPLIERS (HCM) <br /> SYSTEM TYPE HEATING CREDIT MULTIPLIERS <br />Attic Radiant Barrier HCM .98 <br /> Multizone HCM .90 <br /> Natural Gas AFUE 68 - .72 .73 . .77 .78 -82 .83. .87 .88. .92 .93. Up <br /> HCM .54 51 47 .44 .42 .40 <br /> Other Fuels HCM 61 .60 .56 .52 .49 .47 <br /> Where more than one credit is claimed, multiply HeM's together. Enter product on page 4. AFUE means Annual Fuel Utilization Efficiency. <br /> <br />9K COOLING SYSTEM MULTIPLIERS (CSMI <br /> SYSTEM TYPE COOLING SYSTEM MULTIPLIERS <br /> RATI NG 7.5. 80. 85. 89. 9.5. 10.0. 10.5 . 110. 11.5. 120. <br />CENTRAL UNITS 79 8.4 8.8 9.4 9.9 10.4 10.9 11.4 11.9 124 <br /> (SEER) CSM 45 43 40 38 36 34 .32 31 .30 .28 <br />PTAC & ROOM UNITS RATING 125. 130. 135. 140. 145. 150. 15.5. 16.0. 16.5. 17.0. 17.5 <br /> (EER) 129 134 139 14.4 14.9 15.4 15,9 16.4 169 17.4 & Up <br /> CSM .27 .26 25 24 24 23 .22 21 .21 .20 .19 <br /> 1991 Minimums. Central Units-Air Cooled 89 SEER, Ground Water Cooled 10,0 EER 1992 Minimums: Central Units-Air Cooled 10.0 SEER. Ground <br />Water Cooled 11.0 EER. PTAC-see Table 9.11A. EER means Enerav Efficiencv Ratio. SEER means SeasonaJ Enerav Efficiencv Ratio <br /> <br />9L COOLING CREDIT MULTIPLIERS (CCMI <br />SYSTEM TYPE COOLING CREDIT MULTIPLIERs/CCM) <br />Celllnq Fans .86 <br />Multllone 90 <br />Cross Ventilation or Whole House Fan (Credit for onlv one) 95 <br />Attic Radiant Barner 95 <br />Where more than one credit is claimed multiolv CCM's toaether. Enter nroduct on Dace 2. <br /> <br />9M HOT WATER MULTIPLIERS HWM) <br />SYSTEM TYPE HOT WATER MULTIPLIERS <br />E'lrcfrlC EF 80. 81 I .82.83 I 84. 85 I 86.87 I 88. ,90 I .91.93 I .94.96 I 97 & UP <br />ReSistance HWM 3879 I 3785 I 3695 I 3609 I 3527 I 3411 I 3302 I 3200 <br />-. .64.65 66 & Up <br /> EF 43 . .4 7 48 . .49 50.51 52.53 54 . .55 56.57 .58. .59 .60 .61 62.63 <br />Natural Gas HWM 2664 2386 2291 2203 2121 2045 1975 1909 1847 1790 1735 <br />~er Fuels HWM 1845 2059 2145 2231 2317 2234 2157 2085 :~018 1955 1895 <br />Water heaters must comply with minimum efficiences in Table 9-7A of the Florida Energy Code. EF means Energy Factor <br /> <br />9N HOT WATER CREDIT MULTIPLIERS IHWCMI <br /> SYSTEM TYPE HOT WATER CREDIT MULTIPLIERS <br />Solar Water Heater SF .1 I .2 I .3 I .4 I 5 6 I .7 I .8 I .9 I 10 <br /> HWCM 9 I 8 I .7 I .6 I .5 .4 I .3 I 2 I 1 I .0 <br />Heal Recovery Unrt With Air-tonditioner Heat Pumo <br />HWCM .62 .58 <br />lJedlcated Heat Pump EF 20 . 2.49 I 25 . 299 30 . 349 I 3.5 & Up <br />1-- HWCM .44 I 35 .29 T 25 <br />A HWM must bp. Ilsed in conJunction With all HWCM See Table 9M SF means Solar Fraction EF means Energy Factor <br /> <br />9P INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST lSee Section 903.2(1)) <br />COMPONENTS REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE III COMPLY WITH ALL INFILTRATION PRESCRIPTIVES ON TABLE 9A. <br />PRACTICE 112 COMPLY WITH PRACTICE 1/1 AND THE FOLLOWING: <br />Exterior Walls and Floors Top plate penetrations sealed. Infiltration barrier installed. Sole olatelfloor ioint caulked or sealed. <br />Exterior Walls & Ceilinqs Penetrations, ioints and cracks on interior surface caulked. sealed or gasketed <br />Ductwork Ductwork in unconditioned soace must be sealed. <br />Fireolaces Equipped with outside combustion air, doors. and flue dampers. <br />Exhaust Fans EQuipoed with damoers. Combustion devices see 903.2(1) <br />PRACTICE 113 COMPLY WITH PRACTICES 1/1 AND 1/2 AND THE FOLLOWING <br />Ceilinas Infiltration barrier installed <br />I nterior Walls Top plate penetrations sealed or ioints & cracks on interior walls caulked. sealed or oasketed. <br />Ilecessed LiqhlS Sealed from conditioned space & insulated from ventilated aWc spaces <br />Ductwork All ductwork located in conditioned space. <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space. exhaust <br />by.products to outside Stoves see 903.2(f). <br /> <br />.6. <br />