Laserfiche WebLink
<br />FORM 900-A-91 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 9 - Residential Point System Method <br />Department of Community Affairs <br /> <br />Climate Zones <br />CENTRA~ 5 6 <br /> <br />NEW CONSTRUCTION <br />ADDITION <br /> <br /> <br />s c. <br /> <br />BUILDER: <br />PERMITTIN <br />OFFICE: <br /> <br />PERMIT <br />NO.: <br /> <br /> <br />GLASS AREA AND TYPE <br /> <br />CLEAR TINT,FILM,SOLAR SCREEN <br /> <br />SINGLE- ITIDso. SINGLE- ~ sa. <br />PANE Fl PANE ~ FT. <br /> <br />DOUBLE- ITID SO. DOUBLE- ITID sa. <br />PANE Fl PANE FT. <br /> <br />PROJECT NAME <br />AND ADDRESS: <br /> <br />OWNER:~ <br /> <br />MULTIFAMILY AITACHED <br />SINGLE-FAMILY DETACHED ~ <br /> <br />IF MULTIFAMILY, NUMBER OF CONDITIONED ~ sa. <br />UNITS COVERED BY [IJJ FLOOR AREA ~ FT. <br />THIS SUBMITTAL PREDOMINANT rn ~ <br />EAVE OVERHANG Z. 0 <br />CHECK IF THIS SUBMITTAL LENGTH . FT. <br />REPRESENTS A WORST CASE PORCH OVERHANG ICl 0 <br />CONDITION: IZI LENGTH ~. t:J FT. <br /> <br /> NET WALL AREA AND INSULATION <br />EXTERIOR MASONRY R = EXTERIOR FRAME R - EXTERIOR STEEL R - EXTERIOR LOG R - <br />ITIIJJ SO, m.D c:Iili[li] SO. DD ITIIJJ SO m [IIIIJ SO. m <br /> FT ; "'.; (... FT '. '. FT FT <br />ADJACENT MASONRY R = ADJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG R - <br />ITIIJJ SO, m,D [llillso, [IJ ITIIJJ SO, m [IIIIJ SO. m <br /> FT j; ,.:> FT FT FT <br /> <br /> CEILING AREA AND INSULATION FLOOR TYPE AND INSULATION <br />UNDER ATTIC R= SINGLE ASSEMBLY R = SLAB PERIMETER R= RAISED WD D CON D R= <br />~sa. [ill ITIIJJsa. m ~FT. rn ITIIJJsa. m <br />FT. FT. FT. <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HVAC CREDITS HOT WATER SYSTEM HOT WATER CREDITS <br />IN o CENTRAL D ELECTRIC STRIP ~ HEAT [rRI CEILING FANS E2I ELECTRIC SOLAR: D.m <br />UNCONDITIONED <br />SPACE R = D ROOM D NATURAL GAS PUMP ~ CROSS VENTILATION D NATURAL GAS SJ = <br /> HEAT RECOVERY (CHECKI 0 <br />rn.~ D PACKAGE TERMINAL D ROOM UNIT OR D OTHER D WHOLE HOUSE FAN o OTHER FUELS <br />FUELS DEDICATED <br />IN CONDITIONED AIR CONDITIONER PACKAGE TERMINAL o NONE D ATTIC RADIANT D NONE HEAT P~MP: D ,m <br />D NONE HEAT PUMP <br />SPACE R = BARRIER EJ - <br />m,o SEER/EER = rn,~ COP/HSPFI ~ ~ D MULTIZONE EF = .~ij NUMBER OF ~ <br />AFUE = ,0 Cl BEDROOMS = <br /> <br />INFILTRATION ~ lliJiliJillJ CJiliJ. ~ <br />PRACTICE USED X 100 = <br />o #1 ~ #2 0 #3 TOTAL AS-BUILT POINTS TOTAL BASE POINTS CALCULATED E.P.I. <br />CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS. <br /> <br />I hereby certify that the plans and specifications covered by the calculation are in compliance with the <br />Florida Energy Code. <br /> <br />PREPARED BY: ~m.... ~"t: 0:':. DATE: $-dQ.c(z.... <br /> <br />I hereby certify that this building is in compliance with the Florida Energy Code, <br /> <br />Review of plans and specifications covered by this calculation indicates compliance with <br />the Florida Energy Code, Bef onstruction is completed, this building will be inspected <br />for compliance in accorda Sectio .908, F.S. <br /> <br />BUilDING OFFICIAL: <br /> <br /> <br />OWNER AGENT: <br /> <br />DATE: <br /> <br />DATE: <br /> <br />9A I PRESCRIPTIVE MEASURES (must be met or exceeded by all residences,) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904.1 Maximum of 0.34 CFM per linear foot of operable sash crack (includes sliding glass doors). <br />EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. ft. of door area: solid core, wood panel, insulated or glass doors only. <br />ADJACENT DOORS <br />EXTERIOR JOINTS 904.1 To be caulked, gasketed, weatherstripped or otherwise sealed. <br />& CRACKS <br />WATER HEATERS 904.2 Comply with efficiency requirements in Table 9-7A. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (gas) must be provided. External or built-in heat trap required. <br />SWIMMING POOLS 904.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a <br />& SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 78%. <br />SHOWER HEADS 904.5 Water flow must be restricted to no more than 3 Qallons oer minute at 80 PSIG. <br />HVAC DUCT 904.6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned <br />INSULATION space and air handlers located in attics must be insulated to a minimum R-4.2 (R-6 after 1/1/92). <br />& INSTALLATION <br />HVAC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system. <br />INSULATION 904.9 Ceilings-Min. R-19. Common Walls-Frame R-11 or CBS R-3. Common Ceilings & Floors R-11. <br /> <br />- 1 - <br />