Laserfiche WebLink
<br />FOR1JI1000-C-91 <br />SMALL ADDITIONS <br />AND RENOVATIONS <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 10 - Residential Prescriptive Compliance Method <br />Department of Community Affairs <br /> <br />Climate Zones <br />CENTRAL 4 5 6 <br /> <br />COMPLIANCE WITH SECTION 10 OF THE FLORIDA ENERGY EFFICIENCY CODE MAY BE DEMONSTRATED BY USE OF FORM 1 0ll0C-91 FOR ADDITIONS OF 600 SOUARE FEET OR LESS. AND RENOVATIONS <br />TO SINGLE AND MULTIFAMILY RESIDENCES ALTERNATIVE METHODS ARE PROVIDED FOR ADDITIONS BY USE OF FORM 1000A-91 or 9OOA-91 <br /> <br />:::;-.. -; -) C~ 8""")j. f.\'-l \~ BUILDER: <br /> <br />PERMITTING <br />OFFICE: <br /> <br />PERMIT <br />NO.: <br /> <br />PROJECT NAME <br />AND ADDRESS: <br /> <br />OWNER: <br /> <br />-." (",. <br />~ "--. ~~ t'- <br /> <br />'~C v,S'T-""- <br /> <br /> <br />sQ?J 60 <br />~ <br /> <br /> 0 CONDITIONED ITliIill SO NEW GLASS AREA AND TYPE <br />RENOVATION TINT.FILM.50LAR SCREEN <br /> IF MULTIFAMILY. NUMBER OF FLOOR AREA ) FT CLEAR <br />ADDITION ~ UNITS COVERED BY PREDOMINANT rn.~FT SINGLE- ~~~ SINGLE- [[ill SO <br /> EAVE OVERHANG <br /> 0 ITIJ LENGTH PANE PANE FT <br />MULTIFAMILY ATTACHED THIS SUBMITTAL <br /> PORCH OVERHANG ffiB DOUBLE [[ill SO DOUBLE- [[ill SO <br />SINGLE-FAMILY DETACHED ~ LENGTH . FT PANE FT PANE FT <br /> WALL TYPE AND INSULATION CEILING TYPE AND INSULATION FLOOR TYPE AND INSULATION <br />FOR ADDITIONS ONLY: WOOD FRAME MASONRY UNDER ATTIC: 5EJ. ~ WOOD MASONRY <br />PERCENTAGE EXTER~O~ [ill]. (g EXTER~O~ m.D Rc RAISE~ = WlJ. [9 RAISED _ IT] 0 <br />OF GLASS R - . <br />TO FLOOR ADJAC~N~ CD. D ADJA~E~T: m.D SINGLE ASSEMBLY m.D COMMO~ OJ 0 COMMRO~ IT1D <br /> R = R - . <br />[00% COMMRO~ CD. 0 COM~O~; []J.n COMMON; m.D SLAB-ON- _ OJ 0 <br /> R= GRADE R - . <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HOT WATER SYSTEM <br />IN ~ CENTRAL 0 NONE 0 ELECTRIC STRIP ~ HEAT PUMP ~ ELECTRIC o SOLAR <br />UNCONDITIONED 0 0 0 o NATURAL GAS o HEAT RECOVERY <br />SPACE R = ROOM NATURAL GAS ROOM/PTHP <br />rn.[g 0 PTAC 0 OTHER FUELS 0 NONE o OTHER FUELS o OED. HEAT PUMP <br />IN CONDITIONED 0 NO NEW SYSTEM o NO NEW SYSTEM o NO NEW .~ SF/EF = D.m <br />SPACE: R = [EUQ1 ~ i::Ji SYSTEM EF c <br />m.D SEERIEER = COPIHSPFIAFUE = .....>.L?ioj }':'.f)1:~ I~;, 6,..-, rn <br /> NUMBER OF BEDROOMS = <br /> <br />I hereby certify that the plans and specifications covered by the calculation are In compliance With the <br />Florida Erlergy ~._> <br /> <br />PREPARED BY .\TJ-~, ~~;(!. Aj-:l DATE (". 1 C, ,(',1.. <br /> <br />I hereby certify that this building is in compliance WIth the Florida Energy Code <br /> <br />Review of plans and specifications covered by this calculation indicates compliance with <br />the Florida Energy Code. 8efor nstr tlon is completed. this bUll II be inspected <br />for compliance In accordanc i S t n 5539GB. F.S <br /> <br />BUILDING OFFICIAL <br /> <br /> <br />OWNER AGENT: <br /> <br />DATE <br /> <br />DATE <br /> <br />TABLE 10A[ MINIMUM REQUIREMENTS FOR ALL PACKAGES <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Wlfoo!DOWS 904.1 Minimum of 0.34 CFM per linear foot of operable sash crack (includes sliding glass doors). V <br />EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. ft. of door area: solid core, wood panel, insulated or glass doors only. v"'" <br />ADJACENT DOORS <br />EXTERIOR 904.1 To be caulked, gasketed, weatherstripped or otherwise sealed. <br />JOINTS & CRACKS .... <br />SOLE & TOP 903.2 Sole plates and penetra1ions through top plates of exterior walls must be sealed. <br />PLATES \. <br />INFILTRATION 903.2 Infiltration barrier must be installed in exterior walls & raised wood floors. <br />BARRIER , <br />INTERIOR 903.2 All openings in interior surfaces of ceilings and exterior walls must be sealed. <br />JOINTS/CRACKS . <br />FIREPLACES 903.2 Fireplaces must have flue dampers, glass doors and outside combustion air intakes. 1\ \\ <br />EXHAUST FANS 903.2 Exhaust fans ven1ed to unconditioned space shall have dampers. except for combustion <br /> devices with integral exhaust ductwork. t ,;,' <br />WATER HEATERS 904.2 Comply with efficiency requirements in Table 9-7A. Swi1ch or clearly marked circuit breaker (electric) <br /> or cutoff (gas) must be provided. External or built-in heat trap required. "... <br />SWIMMING 904.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a <br />POOLS & SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 7B%. \ <br />HOT WATER 904.4 Insula1ion is required only for recirculating systems. including heat recovery units. In such cases. <br />PIPES piping heat loss shall be limited to a maximum of 17.5 BTUH per linear foot of pipe. , ) r <br />SHOWER HEADS 904.5 Water flow mus1 be restricted to no more than 3 gallons per minute at BO PSIG. . " . <br />HVAC DUCT 904.6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached. <br />CONSTRUCTION. sealed, insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned <br />INSULATION & space and air handlers located in attics must be insula1ed to a minimum R-4.2 (R-6 after 1/1/92). /' <br />INSTALLATION <br />HV AC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system. t, i <br />RENOVATIONS 1003.0 Meets 1he requirements of sec. 1003.0. See step 3 of page 2 of this form. I',:/'r <br />ONLY GLASS <br /> <br />-1 - <br />