<br />FORM 800A.91
<br />Non-Residential Buildings
<br />
<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />SECTION 8 · SIMPLIFIED ANNUAL ENERGY METHOD
<br />ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS
<br />
<br />ALL CLIMATE ZONES
<br />
<br />PROJECT NAME:
<br />ADDRESS: 7-
<br />CITY ZIP CO
<br />BUILDER:
<br />OWN ER:
<br />
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE u AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrele (CBS) .11 '2.Z~ Under allic .04 4414- Slab-on-grade / Wood 6IlA!6 Single, wall 1;1 57!)
<br />Wooo Irame Smgle Assembly Raised Wood ./ Metal Double, wall . Be; 5~
<br />Melal Irame Other Raised concrete /' Insulated Single, rool
<br />InSulation R-value Insulallon A-value Insulation A-value V Other Double, rool
<br />
<br /> SYSTEMS INFORMATION
<br /> AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTU/H TYPE
<br />Unitary & Heat Pump /7 Y2- Central & Heat Pump Electric
<br /> 103 SEEA tif
<br /><65,000 Blu/h --- < 65,000 Btu 1 h _ HSPF Aesistance
<br /> - 0
<br />,,65.000 Bluth --_._--- EER -- IPLV - ~ 65,000 Btu I h COP Oed Heat Puma
<br /> - -
<br />Water Cooled -- - EER .--- IPLV ---- Gas
<br /> Waler cooled - COP - Natural 0
<br />Evaporatlvely Coaleo EER
<br /> ---- -- EvapOrallVely cooled _COP LPG 0
<br />PTAC .. EER ~~_. ElectriC reSistance -L COP ~ Oil 0
<br />Cnlllers ---.- cOP ~ IPLV ---- Gas/Oil (circle one) HAU 0
<br />Other -_.~--_.- ___n__ -- ----- < 225,000/300,000 Btu/h _ AFUE Other --
<br /> -
<br />LIGHTING KW: /I.ot 20 225,000/300,000 Btu/h _E, -
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />Windows 502A Maximum of ,37 cfm per linear foot of operable sash crack, V
<br />Doors 502A Maximum of 1,25 cfm per square foot of door area. ,j
<br />Joints/Cracks 502.4 To be caulked, gaskeled, weatherstripped or otherwise sealed, "
<br />Reheat 503,3 Supply air restricted to set cold/hot deck temperature to meet load of worst case zone, Resistance reheat prohibited ~
<br />Ventilation 503A Supplied with readily accessible switch tor shut-off and/or volume reduction when ventilation is not required, I,
<br />HVAC EffiCiency 503A Minimum efficiencies-Heating: Tables 5-4, 5-5 & 5-5, Cooling: Tables 5-7A, 5-7B, 5-8 & 5-'3, ,
<br />Transport Energy 503.5 Minimum of 8,0, "
<br />Balanclna 503,6 Provide means for balancinQ HVAC air system & water distribution system, u
<br />HVAC Controls 503,7 Separate readily accessible manual or automatic thermostat for each system, ,J
<br />HV AC Ducts 503.8 Air ducts. fittings, mechanical equipment and plenum chambers shall be mechanically attached. sealed.
<br /> 503,9 insulated and installed in accordance with the criteria of sections 503,8. 503,9 and 503,10, J
<br /> 503,10
<br />Piping Insulation 503.11 In accordance with Table 5-10, . }
<br />Water Heaters 504.2 Automatic electric storage water heaters s 120 gallons and gas & oil-fired storage water heaters
<br /> s 75,000 Btu/h shall meet performance minimums in Table 5-11. Larger sized water heaters shall .J
<br /> meet minimums in Table 11-1 of Standard RS-9 after 1/1/92,
<br />SWimming Pools 504.2 Spas & heated pools must have covers, Nan-commercial pools must have pump timer. Al.A.
<br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 78%,
<br />Hot Water Pipe 504.4 Piping heat loss is limited to 17,5 Btu/h linear foot of pipe for recirculating systems (see Table 5-12), ! J
<br />Insulation
<br /> -
<br />Water Fixtures 504,5 Water flow restricted 10 maximum of 3 gpm at 80 psig; toitets maximum 3.5 gallon flush, .J.
<br /> Public lavatory fixture maximum flow of ,5 gpm or .5 gallon if has self-closing valve,
<br />Lighting 50S,' Minimum Ballast Efficacy Factors are listed in Table 5-14, 1/
<br />SECTION . CO.P~ SECTION 4 COMPLIANCE I hereby certify that !!!.e ~n~~sl>ecificatlons cove,,;d by lhe ~""Iculation are In compliance
<br />Budget (Table 8-1) Computer program used: with the Florida e J\., A A ' ,
<br />Building MBTU / SF I. Section 5 Budget: PREPARED By~1l -or .-\ (111 I ~,- DA 'TEL. -l \ .9 "L
<br />Conditioned sq It. 4 Section 4 Total: I hereby certifyt~'~r:.b~ ~~sll~mPliance withte :ld3 Energy C';;; --~
<br /> OWNER/AGENT: ,,~ f. I" ,c.. _ DATE' L :LI _. L
<br />Compliance with Section 8 was demonstrated by a Prescriptive Measures Review at plans and 't~ifi~ cove~'dbY this calculation indicates com~;,~~ce with Ihe
<br />methOdology or by Dual Calculation Flonda Energy Code, e\ore ctlo~leled' this bUilding ~1)e ,nspecled tor
<br />B 807.2 Supermarkets B 809.2 BaSIC Features compliance in accordance wi e on 5..S _
<br />807 3 Restaurants 809,3 Dual Calculation BUILDING OFFICIAL, ^ .A - . -
<br /> -'7 "')f r _ 'iI' ?- -~~
<br />807 4 Kitchens Budget DATE:
<br /> ,
<br />
|