<br />FORM 800A.91
<br />Non.Resldenlial Buildings
<br />
<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />SECTION 8 · SIMPLIFIED ANNUAL ENERGY METHOD
<br />ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS
<br />
<br />ALL CLIMATE ZONES
<br />
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrele (CBS) ./1 '2. 'Z 5't Under allic 1.04- 44-1A- Slab-on-grade ./ Wood ~L.A!6 Single, wall I~ I 570
<br />Wood Irame Single Assembly Raised Wood ./ Metal Double, wall .el: "5"~
<br />Melal Irame Other Raised concrete V Insulated Single, rool
<br />Insulallon A.value Insulation A-value Insulation R-value V Other Double, rool
<br />
<br /> SYSTEMS INFORMATION
<br />AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTU/H TYPE
<br />Unitary & Heal Pump ~ Central & Heat Pump Electric
<br /><65,000 BlUth m_2L SEEA < 65,000 Btu 1 h _ HSPF Resistance ~
<br /> - 0
<br />,,65,000 Bluth - EEA - IPLV - 2: 65,000 Blu 1 h _COP Oed, Heal Pump
<br /> -
<br />Waler Cooled - EER - IPLV - _COP Gas
<br /> Water cooled - Natural 0
<br />Evaporalively Cooled --- EER - Evaporatively cooled _COP 0
<br /> qS. 5"3~ LPG
<br />PTAC --- EER _. Electric resistance ----1- COP 0
<br /> Oil
<br />Chillers ---- COP - IPLV - Gas/Oil (circle one) HAU 0
<br />Olner ---- --.- -- - < 225,0001300,000 Blu/h _ AFUE Other
<br /> -
<br />LIGHTING KW: II. at 2: 225,000/300,000 Btulh _Et -
<br />
<br />COMPONENTS SECTION
<br />Windows 502,4
<br />Doors 502,4
<br />Joints/Cracks 502,4
<br />Reheat 503,3
<br />Ventilation 503.4
<br />HVAC Efficiency 503.4
<br />Transport Energy 503,5
<br />Balancino 503,6
<br />HV AC Controls 503.7
<br />HV AC Ducts 503,B
<br /> 503.9
<br /> 503,10
<br />Piping Insulation 503,11
<br />Water Heaters 504.2
<br />Swimming Pools 504.2
<br />& Spas
<br />Hot Water Pipe 504,4
<br />Insulation
<br />Water Fixtures 504,5
<br />Lighting 505,'
<br />
<br />SECTION 8 COMP~LANC
<br />Budget (Table 8-1):
<br />Building MBTU/SF: t.
<br />Conditioned sQ, It.:
<br />
<br />PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />
<br />REQUIREMENTS
<br />
<br /> CHECK
<br /> \J
<br /> \J
<br /> l
<br /> \
<br />, \
<br /> \.
<br /> I.
<br /> I.
<br /> II
<br /> J
<br /> J
<br /> .J
<br /> l).~'
<br />! J
<br /> i
<br /> V
<br />
<br />Maximum of ,37 cfm per linear foot of operable sash crack.
<br />Maximum of 1 ,25 cfm per square foot of door area.
<br />To be caulked, gasketed, weatherstripped or otherwise sealed,
<br />Supply air restricted to set cold/hot deck temperature to meet load of worst case zone. Resistance reheat prohibited
<br />Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required,
<br />Minimum efficiencies-Heating: Tables 5-4, 5-5 & 5-6. Cooling: Tables 5-7A, 5-7B, 5-8 & 5.9,
<br />Minimum of 8.0,
<br />Provide means for balancino HV AC air svstem & water distribution svstem.
<br />Separate readily accessible manual or automatic thermostat for each system,
<br />Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed,
<br />insulated and installed in accordance with the criteria of sections 503.8. 503,9 and 503.10,
<br />
<br />In accordance with Table 5-10.
<br />Automatic electric storage water heaters 5120 gallons and gas & oil-fired storage water heaters
<br />575.000 Btuth shall meet performance minimums in Table 5-11. Larger sized water heaters shall
<br />meet minimums in Table 11-1 of Standard RS-9 after 1/1/92.
<br />Spas & heated pools must have covers, Non-commercial pools must have pump timer,
<br />Gas spa & pool heaters must have minimum thermal efficiency of 78%,
<br />Piping heat loss is limited to 17,5 Btu/h linear foot of pipe for recirculating systems (see Table 5-12),
<br />
<br />Water flow restricted to maximum of 3 gpm at 80 psig; toilets maximum 3.5 gallon flush.
<br />Public lavatory fixture maximum flow of ,5 gpm or ,5 gallon if has self-closing valve.
<br />
<br />Minimum Ballast Efficacy Factors are listed in Table 5-14.
<br />
<br />SECTION 4 COMPLIANCE
<br />Computer program used:
<br />Section 5 Budget:
<br />Section 4 Total:
<br />
<br />I hereby certify that t~ "2"~ti'flcations covered. by. lne calculation are ,n compliance
<br />with the Florida Ener . ' / :'" ,
<br />PREPARED BY: [i1 J M '11,0._x.. L~OATE l-'L\-9'--
<br />I hereby certify that I~IS _uil ~Ts~on\~nce witt. the Florida Energy Code 9
<br />OWNER/AGENT: \ \ 1 A.A Cr \ . II , I ~ -(.:~E: ~ 1- \. t...-
<br />
<br />Review of plans and s~~ ion't ~~~er by his calculation indicates compliance with the
<br />Flonda Ener,gy Code. Belo~~ '~'s ",p1eted,this bUildin9~1JiII ':nspected for
<br />compliance In accordance ~ on F,S. -
<br />BUILDING OFFICIAL: '~rJ J A rl I..
<br />DATE: "'7 ' ""\.r"VS _ 0 '71
<br />
<br />Compliance with Section 8 was demonstrated by a Prescriptive
<br />methodology or by Dual Calculation:
<br />~ 807.2 Supermarkets
<br />807.3 Restaurants
<br />8074 Kitchens
<br />
<br />Measures
<br />
<br />o 809,2 Basic Features
<br />o 809,3 Dual Calculation
<br />Budget