Laserfiche WebLink
<br />FORM 1000-C-91 <br />SMALL ADDITIONS <br />AND RENOVATIONS <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 10 - Residential Prescriptive Compliance Method <br />Department of Community Affairs <br /> <br />Climate Z9Q,es <br />CENTRAL(Y5 6 <br /> <br />COMPLIANCE WITH SECTION 10 OF THE FLORIDA ENERGY EFFICIENCY CODE MAY BE DEMONSTRATED BY USE OF FORM 100QC,91 FOR ADDITIONS OF 600 SOUARE FEET OR LESS. AND RENOVATIONS <br />TO SINGLE AND MULTIFAMILY RESIDENCES ALTERNATIVE METHODS ARE PROVIDED FOR ADDITIONS BY USE OF FORM 1000A-91 or 9OOA-91 <br /> <br />BUILDER: <br /> <br />PERMITTING <br />,-. OFFICE: <br />PERMIT <br />NO.: <br /> <br />PROJECT NAME <br />AND ADDRESS: <br /> <br /> <br />~ <br /> <br /> <br />5060 <br />~ <br /> <br />OWNER: <br /> <br />RENOVATION <br />ADDITION <br /> <br />N <br />o <br />o <br /> <br />CONDITIONED ~I SO NEW GLASS AREA AND TYPE <br />FLOOR AREA ~ FT CLEAR TINUILM.SOLAR SCREEN <br />PREDOMINANT rn ~ SINGLE, mIJ- SO SINGLE, ITJJ] SO <br />EAVE OVERHANG . () FT PANE FT PANE FT <br />LENGTH . <br />PORCH OVERHANG m 0 DOUBLE'ITJJ]SO DOUBLE. ITJJ] sa <br />LENGTH . FT PANE FT PANE FT <br />WALL TYPE AND INSULATION CEILING TYPE AND INSULATION FLOOR TYPE AND INSULATION <br />WOOD FRAME MASONRY UNDER ATTIC: flFl.O WOOD MASONRY <br />EXTER~O~ WIJ. ~ EXTE~O~ rn. 0 R 0 lLILJ RAISE~ = [II D RAISE~ = DJ.D <br />D SINGLE ASSEMBLY morn 0 COMMON rn <br />ADJAC:N~ rn . 0 ADJA~E~T rn. R = . COM~O~ . R = <br /> <br />COMMRO~ rn. 0 COM~O~: .0 COMMON: R 0 m.o ~~~~t R = rn. 0 <br /> <br />UNITS COVERED BY <br /> <br />THIS SUBMITTAL OJ] <br /> <br />IF MULTIFAMILY. NUMBER OF <br /> <br />MULTIFAMILY ATTACHED <br /> <br />SINGLE-FAMILY DETACHED <br /> <br />FOR ADDITIONS ONLY: <br /> <br />PERCENTAGE <br />OF GLASS <br />TO FLOOR <br /> <br />[}1]% <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HOT WATER SYSTEM <br />IN 0 CENTRAL o NONE 0 ELECTRIC STRIP D HEAT PUMP D ELECTRIC D SOLAR <br />UNCONDITIONED D D D D NATURAL GAS D <br />SPACE: R = ROOM NATURAL GAS ROOM/PTHP HEAT RECOVERY <br />m.o D PTAC D OTHER FUELS D NONE D OTHER FUELS D DED HEAT PUMP <br />~ NO NEW SYSTEM ~ NO NEW SYSTEM ....,.---, ~ NO NEW ,IT] SF/EF = o.rn <br />IN CONDITIONED SYSTEM EF c <br />SPACE: R = SEER/EER = IT].O cOP I HSPF I AFUE = D ,[1_J rn <br />m.o NUMBER OF BEDROOMS = <br /> <br /> <br />ReVIew of plans and specifications covered by this calculation Indicates compliance with <br />the FlOrida Energy Code. Before construction is completed. thi uilding will be Inspected <br />for compliance In accordanc th Secti 53.90B, F.S-' <br /> <br />~~;;~=YE~:::~: and spe7atlons :overe~ by ~h,e calculation are In compliance With; . <br /> <br />PREPARED BY' ",." . DATE 7 -~ 1 2- <br />/ '\ <br />I hereby certify that'this building is in compliance with the Florida Energy Code <br /> <br />OWNER AGENT: <br /> <br />DATE <br /> <br />DATE <br /> <br /> <br />BUILDING OFFICIAL <br /> <br />TABLE 10AI MINIMUM REQUIREMENTS FOR ALL PACKAGES <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904.1 Minimum of 0.34 CFM per linear foot of operable sash crack (includes sliding glass doors). }' <br />EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. ft. of door area: solid core, wood panel, insulated or glass doors only. -/, <br />ADJACENT DOORS <br />EXTERIOR 904.1 To be caulked, gasketed, weatherstripped or otherwise sealed. 'I <br />JOINTS & CRACKS <br />SOLE & TOP 903.2 Sole plates and penetrations through top plates of exterior walls must be sealed. '/.- <br />PLATES <br />INFILTRATION 903.2 Infiltration barrier must be installed in exterior walls & raised wood floors. 'f <br />BARRIER <br />INTERIOR 903.2 All openings in interior surfaces of ceilings and exterior walls must be sealed. '1 <br />JOINTS/CRACKS <br />FIREPLACES 903.2 Fireplaces must have flue dampers, glass doors and outside combustion air intakes. IV II <br />EXHAUST FANS 903.2 Exhaust fans vented to unconditioned space shall have dampers. except for combustion J}.f: <br /> devices with integral exhaust ductwork. <br />WATER HEATERS 904.2 Comply with efficiency requirements in Table 9-7A. Switch or clearly marked circuit breaker (electric) I <br /> or cutoff (gas) must be provided. External or built-in heat trap required. ~7i <br />SWIMMING 904.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a '-r! <br />POOLS & SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 78%. 1-' ,I <br />HOT WATER 904.4 Insulation is required only for recirculating systems, including heat recovery units. In such cases. /1 <br />PIPES piping heat loss shall be limited to a maximum of 17.5 BTUH per linear foot of pipe. /1/'1/ <br />SHOWER HEADS 904.5 Water flow must be restricted to no more than 3 gallons per minute at BO PSIG. L i~ <br />HVAC DUCT 904.6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached. <br />CONSTRUCTION. sealed. insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned ,I <br />INSULATION & space and air handlers located in attics must be insulated to a minimum R-4.2 (R-6 after 1/1/92). t... 1: <br />INST ALLA TION <br />HVAC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system. /.,_J <br /> .' <br />RENOVATIONS 1003.0 Meets the requirements of sec. 1003.0. See step 3 of page 2 of this form. ) <br />ONLY GLASS 1. /1 <br /> <br />-1 - <br />