My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
92-2687
Zephyrhills
>
Building Department
>
Permits
>
1992
>
92-2687
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 9:55:31 AM
Creation date
4/24/2006 2:51:32 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Building Department - Date
8/21/1992 12:00:00 AM
Permit #
92-2687
Building Department - Name
HILTON CONST
Address
38343-38345 A AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />FORM 1000-A-91 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUilDING CONSTRUCTION <br />Section 10 - Residential Perscrlptlve Compliance Method <br />Department of Community Affairs <br /> <br />Climate Zones <br />CENTRA@ 5 6 <br /> <br />COMPLIANCE WITH SECTION 10 OF THE FLORIDA ENERGY EFFICIENCY CODE MAY BE DEMONSTRATED BY USE OF FORM1OOOA.91 FOR SINGLE AND MUlTIFAMILY RESIDENCES OF 3 STORIES OR tfSS <br />IN HEIGHl AND ADDITIONS TO EXISTING RESIDENTIAL BUILDINGS. TO COMPLY, A BUILDING MUST MEET OR EXCEED ALL OF THE ENERGY EFFICIENCY PRESCRIPTlVES IN ANY ONE OF THE <br />PRESCRIPTIVE COMPONENT PACKAGES AND COMPLY WITH THE PRESCRIPTIVE MEASURES LISTED IN TABLE lOA OF TfjIS FORM. COMPLIANCE BY THIS METHOD WILL BF. IN MOST CASES, <br />EQUIVALENT TO AN EPI OF 100 POINTS MUss. AN ALTERNATIVE METHOD IS PROVIDED FORADDITIONS OF 600 SQUARE FEET OR LESS BY USE OF FORM l00OC.91 IF A BUILDING DOES NOT <br />COMPLY WITH TIllS METHOD, IT MAY STILL COMPLY UNDER SECTION 9 OF THE CODE. <br /> <br /> <br />NEW r.ONSTRUCTlON 0 <br /> <br />ADDITION 0 <br /> <br />MULTifAMILY ATTACHED 0 <br />(3 slolle<; or less) <br />SINGLE. fAMILY DETACHED 0 <br /> <br />IF MULTifAMILY, NUMBER Of <br />UNITS ClNERED BY [IT] <br />THIS SUBMITTAL <br /> <br />CHECK If THIS SUBMITTAL <br />REPRESfNTS A WORST r.ASE <br />CONDITION 0 <br /> <br /> <br />CLIMATE 4 f'i'I 50 60 <br />lONE: La <br />~~:SDICTlON ~ <br /> <br />BUILDER: <br /> <br />OWNER: <br /> <br />PERCENTAGE <br />OF GLASS GTN <br />TO FLOOR I.j.J...':J % <br /> <br /> <br />CONDITIONED r::C;'r;r=r=j sa <br />fLOOR AREA ~ rr <br />PREDOMINANT rn ~ <br />EAVE OVERHANG ,. 0 FT <br />LENGTH . <br />PORCH lNERHANG .n-:J 1AI0 <br />LENGTH ~.~ FT <br /> <br />COMPLIANCE (Jj <br />PACKAGE <br />CHOSEN <br /> <br />UNDER ATTI;: = m. [QJ <br />COMMON R = DJ.D <br /> <br />GLASS AREA AND TYPE <br />CLEAR flNUILM,SOLAR SCREEN <br /> <br />SI~A~Lt [[[J] ~~ SI~^~:'lliDJ ~~ <br /> <br />DOUBLE. [[]]]sa DOUBLE [[[J] sa <br />PANE FT PANE f' <br />FLOOR TYPE AND INSULATION <br />WOOD MASONRY <br />RAISED _ [[] 0 RAISED _ []J 0 <br />R - . R . <br />COM~O~[[lD cOM~o~DJD <br /> <br />~~~~~N~:l~ .lJ-- . <br /> <br />CEILING TYPE AND INSULATION <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HOT_~"!.ER SYST~~_____.~ <br />-'IN ---------.--....------- -OCELECTRIC <br />UNCONDITIONED ~ CENTRAL 0 NONE o ELECTRIC STRIP rn HEAT PUMP 0 NONE [J SOLAR <br />SPACE R = ROOM o NATURAL GAS 0 OTflER FUELS o NATURAL GAS [J HEAT RECOVERY <br />[lil. ~ 0 PACKAGED TERMINAL o ROOM UNIT OR o NONE o OTHER FUElS [J DEDICATED HEAT PUMP <br /> AIR CONDITIONER PACKAGED TERMINAL . ffI1J SFIEF = ~.rn <br />IN CONDITIONED rn.~ HEAT PUMP _ <br />SPACE. R = COPIHSPFIAFUE = [JJc2LJ EF = <br />OJ.~ SEERIEER = [JiJ <br /> NUMBER OF BEDROOMS = <br /> <br />t hOfeby cartUy tha~t plans" specifications covered by the CAlculatIon are In compllitnce with Ihe <br />Flondil Energy Cod J. II <br /> <br />PREPARED BV' ""..... -it DATE 10 ~ (. 12- <br /> <br />I h","hy c""11v that fhl. building' . In compliance wilh the Florida Energy Coda <br /> <br />OWNEn AGENT' <br /> <br />DATE <br /> <br />Review 0' plans and specifications covernd bV this calculalion indical(?~ compll:mce wilh <br />Ihe Florida Energy Code Before construction is completed. Ihls building will b~ rnc:ppClpd <br />'orcomPliancaln.ccordance"",..lion..5.i.55~3.. ..FF..SS...... - - n <br /> <br />BUILDINGOFFICtAL: . ..&~. ..c::>-.~ <br /> <br />DATE ./,o - 7- fy <br /> <br />TABLE 10A I MINIMUM REQUIREMENTS FOR ALL PACKAGES <br />COMPQNENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904,1 Minimum 01 0.34 CFM per linear loot 01 operable sash crack (includes sliding glass do~ p;....... <br />EXTERIOR & 904,1 Maximum 01 0,5 CFM per sq. It, 01 door area: solid core, wood panel, insulated or glass doors only. X' <br />ADJACENt" DOORS <br />EXTERIOR 904,1 . To be caulked, gasketed, weatherstripped or otherwise sealed, "- <br />JOINTS & CRACKS <br /> -- ._~ <br />SOLE & TOP 903.2 Sole plates and penetration,s!hrough top plates 01 exterior walls must be sealed, <br />PLATES <br />INFILTRATION 903,2 Infiltration barrier must be Installed in exterior walls & raised wood 1I00rs. -'i\' <br />BARRf.ER - --~-'--- <br />INTERIOR 903.2 All openings in interior surfaces 01 ceilings and exterior walls must be sealed. 'f, <br />JOINTS/CRACKS <br />FIREPLACES 903,2 Fireplaces must have lIue dampers, glass doors and outside combustion air intakes. . '~:;i/j!. <br />EXHAUST FANS 903.2 Exhaust lans vented to unconditioned space shall have dampers. except lor combustion <br /> devices with integral exhaust ductwork. .-- ~}..~. <br />WATER HEATERS 904.2 Comply with efficiency requirements in Table 9.7A, Switch or clearly marked circuit breaker (electric) ." <br /> or cutoff (gas) must be provided. External or built.in heat trap required, -----.----- <br />SWIMMING 904.3 Spas & heated pools must have covers (except solar heated). Non.commercial pools must have a J}-A <br />POOLS & SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency 01 78%. <br />HOT WATER .-- <br />904.4 Insulation is required only lor recirculating systems, Including heat recovery units. In such casp-s. f. <br />PIPES piping heat loss shall be limited to a maximum 01 17,5 BTUH per linear loot 01 pipe. <br /> ---- :=~::. <br />?HOW!=R HEADS 904.5 Water 1I0w must be restricted to no more than 3 gallons per minute at 80 PSIG. <br />HVAC DUCT 904.6 All ducts. linings. mechanical equipment and plenum chambers shall be mechanic:111y attached. <br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria 01 Section 904.6. Ducts in unconditioned 'f. <br />INSULA liON & space and air handlers located in allics must be insulated to a minimum R.4,2 (R'6 alter 1/1/92). <br />INST ALLA TION 17 <br />--_._----,-- Separate readily accessible manual or automatic thermostat for each system. ~------- <br />HV^C CONTROLS 904.7 <br /> <br />. 1 . <br />
The URL can be used to link to this page
Your browser does not support the video tag.