Laserfiche WebLink
<br />FORM 900-A-91 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 9 - Residential Point System Method <br />Department of Community Affairs <br /> <br />Climate Zones <br />CENTRAt& 5 6 <br /> <br /> <br />PROJECT NAME <br />AND ADDRESS: <br /> <br />N ,,=- <br />CLIMATE 4 r:J ~ 60 <br />ZONE: ~o LJ <br />JU~ISDICTION ~ <br />NO.. ~ <br /> <br />NEW CONSTRUCTION ~ <br />ADDITION 0 <br />MULTIFAMILY ATTACHED 0 <br />SINGLE-FAMILY DETACHED ~ <br /> <br />GLASS AREA AND TYPE <br />CLEAR TINT,FllM,SOLAR SCREEN <br />SINGLE- ~ Set SINGLE- om sa, <br />PANE ~ Fl PANE FT. <br />DOUBLE- om SUo DOUBLE- om sa, <br />~E Fl ~E FT. <br /> <br /> NET WALL AREA AND INSULATION <br />EXTERIOR MASONRY R = EXTERIOR FRAME R = EXTERIOR STEEL R = EXTERIOR LOG R - <br />~W rn.~ lIJllilliJ ~~.' [IT] CIIEnJ SO [ill] [IIIIJ SO. m <br /> FT FT <br />ADJACENT MASONRY R = ADJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG R = <br />[[[]]] SO m.o [[[]]] SO m [[[]]] SO m [IIIIJ w m <br />FT FT FT <br /> <br /> CEILING AREA AND INSULATION FLOOR TYPE AND INSULATION <br />UNDER ATTIC R= SINGLE ASSEMBLY R= SLAB PERIMETER R ~,<<\ RAISED WD D CON D R= <br />~SO ~ [[[]]]sa, m I Ill~~IF1 lliiJ [[[]]]sa, m <br />FT. FT. F1 <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HVAC CREDITS HDT WATER SYSTEM HDT WATER CREDITS <br />IN I2f.cENTRAL D ELECTRIC STRIP 1:8 HEAT D CEILING FANS ~LECTRIC SOLAR: 0 m <br />UNCONDITIONED <br />SPACE R = D ROOM D NATURAL GAS PUMP D CROSS VENTILATION D NATURAL GAS SF = . - <br />HEAT RECOVERY ICHECK) ~ <br />cm.~ D PACKAGE TERMINAL D ROOM UNIT OR D OTHER D WHOLE HOUSE FAN D OTHER FUELS <br />FUELS DEDICATED <br />IN CONDITIONED AIR CONDITIONER PACKAGE TERMINAL D NONE D ATIlC RADIANT D NONE HEAT PUMP: o.m <br />D NONE HEAT PUMP <br />SPACE R = BARRIER EF. = <br />m.D SEER/EER = UIQ].1hJ COP I HSPF I ~.rn D MULTIZONE EF = . [XIb] NUMBER OF W <br />AFUE = BEDROOMS = <br /> <br />INFIL TRA TION ~ ~ []5ul~ <br />PRACTICE USED X 100 = <br />~#1D#2D #3 TOTAL AS.BUIL T POINTS TOTAL BASE POINTS CALCULATED E.P.1. <br />CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS. <br /> <br /> <br />OWNER AGEN : <br /> <br />latian are in compliance with the <br /> <br />DATE~ -5C-1' " <br />~, 'BUILDING OFFICIAL: <br />Energy Code, 3 <br />DATE: - O'~'9..::... -DATE: / (f:) <br /> <br /> <br />9A I PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904.1 Maximum of 0.34 CFM per linear foot of operable sash crack (includes sliding glass doors). V- <br />EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. ft of door area: solid core, wood panel, insulated or glass doors only. V' <br />ADJACENT DOORS <br />EXTERIOR JOINTS 904.1 To be caulked, gasketed, weatherstripped or otherwise sealed. <br />& CRACKS V- <br />WATER HEATERS 904.2 Comply with efficiency requirements in Table 9-7A Switch or clearly marked circuit breaker (electric) V- <br /> or cutoff (gas) must be provided. External or built-in heat trap reauired. <br />SWIMMING POOLS 904.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a <br />& SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 78%. <br />SHOWER HEADS 904.5 Water flow must be restricted to no more than 3 aallons per minute at 80 PSIG. -- <br />HVAC DUCT 904.6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, V <br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned <br />INSULATION space and air handlers located in attics must be insulated to a minimum R-4.2 (R-6 after 1/1/92). <br />& INSTAllATION <br />HV AC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system. ,.....- ...." <br />INSULATION 904,9 Ceilings-Min. R-19. Common Walls-Frame R-11 or CBS R-3. Common Ceilings & Floors R-11. - <br /> <br />- 1 - <br />