Laserfiche WebLink
<br />FORM 900-A-91 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 9 - Residential Point System Method <br />~par ent of Community Affairs <br /> <br /> <br />PROJECT NAME <br />AND ADDRESS: <br /> <br />OWNER: <br /> <br />NEW CONSTRUCTION <br />ADDITION <br /> <br />MULTIFAMILY ATTACHED <br />SINGLE-FAMILY DETACHED <br /> <br />Climate Zones <br />CENTRAL 4 5 6 <br /> <br />tv\. 8 RoC-v 1-..( <br /> <br />IF MULTIFAMILY, NUMBER OF CONDITIONED ~2 sa. <br />UNITS ClNERED BY[IJJ FLOOR AREA ~ Ft <br />THIS SUBMITTAL: PREDOMINANT WJ ~ <br />EAVE OVERHANG I <br />CHECK IF THIS SUBMITTAL LENGTH . Ft <br />REPRESENTS A WORST CASE PORCH lNERHANG rT:l 0 <br />CONDITION: 0 LENGTH u21.8 Ft <br /> <br />GLASS AREA AND TYPE <br />CLEAR TINT, FILM, SOlAR SCREEN <br />SINGLE- r-T7T/T71{ / / sa SINGLE- DIO sa. <br />PANE ~ Ft PANE Ft. <br />DOUBLE- DIOsa, DOUBLE- DIO sa. <br />PANE Ft PANE Ft <br /> <br /> NET WALL AREA AND INSULATION <br />EXTERIOR MASONRY R = EXTERIOR FRAME R = EXTERIOR STEEL R = EXTERIOR lOG R = <br />~so rn.~ [[[IJJso, OJ [[[IJJso, OJ [[[IJJ SO OJ <br /> Ft FT FT Ft <br />ADJACENT MASONRY R = ADJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG R = <br />[[[IJJ SO, OJ.D CillIU SO. m [[[IJJ SO. OJ [[[IJJ SO OJ <br /> FT FT FT FT <br /> <br />UNDER ATTIC <br />~sa. <br />~Ft <br /> <br />DUCTS <br />IN <br />UNCONDITIONED <br />SPACE R = <br />rn.~ <br />IN CONDITIONED <br />SPACE R = <br />OJ.O <br /> <br />CEILING AREA AND INSULATION <br />R - SINGLE ASSEMBLY <br />en [[[IJJsa, <br />IfE:J Ft <br /> <br />R- <br />OJ <br /> <br />COOLING SYSTEM <br /> <br />~NTRAL <br /> <br />o ROOM <br /> <br />o PACKAGE TERMINAL <br />AIR CONDITIONER <br /> <br />o NONE <br /> <br />SEERIEER = rn.[;J <br /> <br />HEATING SYSTEM <br />[f}1LECTRIC STRIP I1I1lEAT <br />o NATURAL GAS PUMP <br />o ROOM UNIT OR 0 OTHER <br />PACKAGE TERMINAL FUELS <br />HEAT PUMP 0 NONE <br />COP I HSPF I r:::;l7 ITl <br />AFUE = W.~ <br /> <br />INFILTRATION <br />PRACTICE USED <br />o #1 [f('#2 0 #3 <br /> <br />Il\ereby certify that <br />OWNER AGENT: <br /> <br />SWIMMING POOLS <br />& SPAS <br />SHOWER HEADS <br />HV AC OUCT <br />CONSTRUCTION, <br />INSULATION <br />& INSTALLATION <br />HV AC CONTROLS <br />INSULATION <br /> <br />SLAe PERIMETER <br /> <br />~Ft <br /> <br />FLOOR TYPE AND INSULAnON <br />h == RAISED: we 0 CON 0 <br /> <br />rn []]]]J~~ <br /> <br />R,., <br />OJ <br /> <br />HVAC CREDITS <br />~ILlNG FANS <br />o CROSS VENTILATION <br />~OLE HOUSE FAN <br />o ATIlC RADIANT <br />BARRIER <br />o MULTllONE <br /> <br />HOT WATER SYSTEM <br />~ECTRIC <br />o NATURAL GAS <br />o OTHER FUELS <br />o NONE <br /> <br />EF = . rn <br /> <br />HOT WATER CREDITS <br />SOLAR: 0 OJ <br />S.F. = . <br />HEAT RECOVERY ICHECKI 0 <br />DEDICATED <br />HE:'~.P~MP: 0 . OJ <br /> <br />NUMBER OF I1;l <br />BEDROOMS = ~ <br /> <br />~ ~ X 100 = UiliJ.[J] <br /> <br />TOTAL AS-BUILT POINTS TOTAL BASI: POINTS CAlCULAnO t.P.I, <br />CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS. <br /> <br />DATE: <br /> <br />Il- f2-q <br />! 1-12--Qt. <br /> <br /> <br />9A PRESCRIPTIVE MEASURES (mult be met ot $xceeded by 811 teeldeneee.) <br />COMPONENTS SECTION REQUIREMENTS <br />WINDOWS 904.1 MaximUm of 0.34 CFM r linear foot Of 0 table sash crack Includes Alldl 14U (fOOts , <br />EXTERIOR & 904,1 Maximum of 0.5 CFM ~r sq. ft. of door area: solid !:lore, WOOd !)4nel, Insulated or glass doors only. <br />ADJACENT OOORS <br />EXTERIOR JOINTS <br />& CRACKS <br />WATER HEATERS <br /> <br />~ <br /> <br />DATE: <br /> <br />904.1 <br /> <br />Review 01 plans and speclilcatloni covered by this calculation Indicates compliance with <br />the I'lorlda Energy Code. Belor con$tnJclfon IS completed, this buildinG Wlh be 1nllp8cted <br />lor compliance In aecorda SectIon .908, F.S. <br /> <br />BUilDING OFFICIAL: <br /> <br />DATE: <br /> <br /> <br /> <br />CHECK <br /> <br />v- <br /> <br />V <br />V <br /> <br />To be caulked, gasketed, weatherstrlpped or otherwise seated, <br /> <br />Comply with efficiency requirements in Table 9-7A. Switch or clearly marked circuit breaker (electric) <br />or cutoff as must be rovided. External or built-in heat tra re ulred. <br />Spas & heated pools must have covers (except solar hMted), Non-commer~ial pools must have a <br />urn timer. Gas s a & I heatl!lrs must have minimum thermal efflcien of 78%. <br />Water flow must be restricted to no more than 3 allons r minute at 80 PSIG. <br />All ducts, fittings, mechanical equipml!lnt and plenum chambers shall be mechanically attached, <br />sealed, insulated and Installed In accordance with the criteria of Section 904.6, Oucts in unconditioned <br />space and air handlers located in attics must be insulated to a minimum R-4.2 (R-6 after 1/1/92). <br /> <br />904,2 <br /> <br />904.3 <br /> <br />904.5 <br />904.6 <br /> <br />904,7 <br />904.9 <br /> <br />..-- <br /> <br />l./" <br /> <br />Separate readily accessible manual or automatic thermostat for each system. <br />Ceilings-Min. R-19. Common Walls-Frame R-11 or CBS R-3. Common Ceilings & Floors R-11. <br /> <br />~ <br />V- <br /> <br />- 1 - <br />