<br />91 HEATJNl;i SYSTEM MULTIPLIERS (HSM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS <br />Central Heat HSPF 6.4 - 6.79 6.6 - 6.69 6.9 - 7.39 7.4 - 7.69 7.9 - 6.39 6.4 ' 6.69 6.9 - 9.39 9.4 - 9.69 <br />Pump Units HSM .53 .50 .49 .46 .43 .41 .36 .36 <br /> HSPF 9.9 - 10.39 10.4 -10,69 10.9 -11.39 11.4 - 11.69 11 ,9 ' 12.39 12.4 & UD <br /> HSM ,34 ,33 .31 .30 .29 .26 <br />PTHP COP 2.6 ' 2.69 2.7 - 2.69 2.9 - 3.09 3.10 - 3.29 3.30 - 3.49 3.50 - 3.69 3.70 - 3.69 3.90.4,19 <br /> HSM .38 .37 ,34 .32 .30 .29 .27 .26 <br />Electric Strip 1,0 <br />Gas & OIher Fuels 1.0 (See Table 9J for Credit MultiDlier) <br />1991 Minimums: Central Units Air Sour~ 6.4 HSPF, Water Source 3.4 COP, Ground Water Source 3.2 COP, PTHP 2.6 COP. <br />1992 Minimums: Central Units-Air Sour~ 6.6 HSPF, Wat"r Source 3.6 COP, Ground Water Source 3.4 COP, PTHP 2.7 COP. <br />HSPF means Heatina Seasonal Performance Factor, COP means Coefficient of Performance. <br />~., v,.......', ". ,_",._ ...",' .. <br /> <br />IJ HEATING CREDIT MULTIPLIERS IHCM) <br /> smEll TYPE HEATING CREDIT MULTIPLIERS <br />Attic Radiant Barrier HCM .96 <br />Multilone HCM .90 . <br />Nalural ~s AFUE .68, .72 73 . .77 76 - .82 .63 - .67 .68 - .92 .93, Uo <br /> HCM .54 51 .47 .44 .42 ,40 <br />Other Fuels HCM .61 .60 ,56 .52 .49 .47 <br />Where more than one credit is claimed, multiply HCM's together. Enter product on page 4. AFUE means Annual Fuel UliIization Efficiency. <br />IK COOLING SYSTEMIIULTlPLlERS ICSMI <br />" SYSTEM TYPE .. . . COOLING SYSrEMMULTlPLlERS <br /> RATING 7.5. 80. 65 - 69. 95- 10.0, 105. 110 - 115. 12.0 - <br />CENTRAL UNITS 7.9 6.4 86 94 9.9 10.4 109 114 11.9 12.4 <br />(SEER) CSM .45 43 .40 .38 .36 .34 ,32 .31 .30 28 <br />PTAC & ROOM UNITS RATING 12.5 - 13.0. 135. 14.0. 145. 15,0. 15.5. 160. 16.5. 17.0. 17,5 <br />(EER) 12.9 134 13.9 14.4 149 15.4 159 16.4 169 17.4 & Uo <br /> CSM .27 .26 .25 .24 .24 .23 .22 21 21 20 .19 <br />1991 Minimums: Central Units-Air Cooled 8.9 SEER. Ground Water Cooled 10.0 EER. 1992 Minimums: Central Units-Air Cooled 10.0 SEER. Ground <br />Water Cooled 11.0 EER. PTAC-see Table 9-llA. EER means Energy Efficiency Ratio. SEER means Seasonal Energy Efficiency Ratio. <br />. . <br />IL COOLING CREDIT MULTIPLIERS ICCMI <br /> SYSrEM TYPE COOLING CREDIT MULTIPLIERS ICCM) <br />Ceiling Fans .86 <br />Multizone .90 <br />Cross Ventilation or Whole House Fan (Credit for only one) .95 <br />Altic Radiant Barrier .95 <br />Where more thAn nne ",..tiit Is claimed. mulllolv CCM's looether. Enter oroduct on oaoe 2, <br />1M HOT WATER MULTIPLIERS lHWMI <br />SYSTEM TYPE HOT WATER MULTIPLIERS <br />Electric EF .60 - .81 I 82. .63 I .84. .85 I .86. .67 I .68. .90 I .91 - .93 I .94. .96 I .97 & Up <br />Resistance HWM 3679 I 3765 I 3695 I 3609 I 3527 I 3411 I 3302 I 3200 <br />Natural Gas EF .43 . ,47 .46 - .49 .51)- .51 .52 - .53 .54 - .55 56 - ,57 .56. .59 60, .61 62.63 .64.65 66 & Uo <br />HWM 2664 2386 2291 2203 2121 2045 1975 1909 1847 1790 1735 <br />Other Fuels HWM 1645 2059 2145 2231 2317 2234 2157 2065 2016 1955 1695 <br />Water heaters must comply with minimum efflclences In Table 9-7A of the Florida Energy Code. EF means Energy Factor. I <br /> <br />8N HOT WATER CREDIT MULTIPLIERS HWCMI <br /> SYSrEM TYPE HOT WATER CREDIT MULTIPLIERS <br />Solar Water Healer SF .1 I .2 I .3 I .4 I .5 6 I 7 I .8 I .9 I 10 <br /> HWCM .9 I .8 I 7 I .6 I .5 .4 I 3 I .2 I .1 I .0 <br />Heat Recovery Unit With Ai r -{;onditioner Heal Pump <br />HWCM 62 .58 <br />Dedicated Heal Pump EF 2.0, 2.49 I 2.5 . 2.99 3.0 . 3.49 I 35 & Up <br />HWCM .44 I .35 .29 I .25 <br />A HWM must be used in conjunction with all HWCM. See Table 9M. SF means Solar Fraction. EF means Energy Factor. <br />IP INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST ISle Section 803.2(f)) <br />COMPONENTS REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE II COMPLY WITH AlL INFILTRATION PRESCRIPTIVES ON TABLE 9A. <br />PRACTICE 12 COMPLY WITH PRACTICE II AND THE FOLLOWING: <br />Exterior Walls and Floors Top plate penetrations sealed. Infiltration barrier Installed. Sole Dlate/floor ioint caulked or sealed. <br />Exterior Walls & Ceilinas Penetrations, joints and cracks on interior surface caulked, sealed or Qasketed. <br />Ductwork Ductwork In unconditioned space must be sealed. <br />Fireplaces Equipped with outside combustion air, doors, and flue damoers. <br />Exhaust Fans Equipped with dampers, Combustion deyices see 903.210. <br />PRACTICE 13 COMPLY WITH PRACTICES '1 AND 12 AND THE FOLLOWING: <br />Ceilings Infiltration barrier Installed. <br />Interior Walls Top olate penetrations sealed or joints & cracks on Interior walls caulked, sealed or aasketed. <br />Recessed Lights Sealed from conditioned seace & insulated from ventilated attic spaces. <br />Ductwork All ductwork located in conditioned seace. <br />Combustion Appliances Be In unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br /> by-products to outside Stoves see 903.2(0. <br /> <br />,6, <br />