<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />FORM 500-A-91 SECTION 5 · BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH
<br />Non.Resldentlal Buildings ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS
<br />Residential Buildings over 3 stories
<br />
<br />8-26-92.
<br />
<br />
<br />PROJECT NAME:
<br />ADDRESS:
<br />CITY. ZIP CODE:
<br />BUILDER:
<br />OWNER:
<br />
<br />ALL CLIMATE ZONES
<br />
<br />
<br />ZONE:
<br />BUILDING CLASSIFICATION S:
<br />. BUILDING PERMIT NO.: ..2.
<br />PERMITTING OFFICE: Z
<br />JURISDICTION NO.: cO I
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILING I FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA I TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrete (CBS).O ~ Under attic a ~ Slab-oOilrade /' Wood Single, wall ( >"~I I~
<br />Wood frame Slhgle Assembly Aalsed Wood Metal Double, wall
<br />Metal frame Other: .. Aalsed concrete Insulated .~ , '2.D Single, roof
<br />Insulation A-value R,= R.OD Insulation A-value R= : 1 <o:rZI Insulation A-value N/A Other Double, roof
<br /> SYSTEMS INFORMATION
<br />AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />lYPE EFFICIENCY TONS TYPE EFFICIENCY BTU I H TYPE
<br />Unitary & Heat Pump ~ Central & Heat Pump Electric
<br /><65,000 Btulh 10. \ SEER < 65,000 Btu 1 h _ HSPF - Resistance R
<br />~,OOO Btulh IO,OeER IPLY ~ 65,000 Btu/h _COP - Dedicated Heat Pump 0
<br />- , Water cooled _COP Gas
<br /> -
<br />Water Cool,ed - EER - IPLY - Evaporatively cooled COP Natural 0
<br />Evaporatlvely Cooled - EER - Electric resistance ]Q COP .%~2. LPG 0
<br />PTAC - EER. - Gas/OIl (circle one) 011 0
<br />Chillers COP IPLY < 225,000/300,000 Btu/h _AFUE ~ HRU 0
<br />- - -
<br />Other: > 225,000/300,000 Btu/h Et Other:
<br />LIGHTING '7 I (OS ,3(095 Lighting Budget (from Table 5-13): I .,
<br />Total Lighting Wattage : Total Conditioned Floor Area , ' = Watts/sq. ft: ,z.~
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />Windows 502.4 Maximum of .37 elm per linear foot of operable sash crack. V,
<br />Doors 502.4 Maximum of 1 .25 cfm per square foot of door area. II
<br />Joints/Cracks 502.4 To be caulked, gasketed, weatherstripped or otherwise sealed, II,
<br />Reheat 503.3 Supply air restricted to set coldlhot deck temperature to meet load of worst case zone. Resistance reheat prohibited. \!
<br />Ventilation 503.4 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. " .
<br />HV AC Efficiency 503.4 Minimum efficiencies-Heating: Tables 5-4, 5-5 & 5-6. Cooling: Tables 5-7A, 5-7B, 5-8 & 5-9, ..
<br />Transport Energy 503.5 Minimum of 8.0.
<br />Balancina .503/6 Provide means for balancing HV AC air svstem & water distribution svstem. .
<br />HV AC Controls 503.7 Seoarate readilv accessible manual or automatic thermostat for each svstem,
<br />HV AC Ducts 503.8 Air ducts. fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, V
<br /> 503.9 Insulated and installed In accordance with the criteria of sections 503.8, 503.9 and .503,1 0,
<br /> 503.1 0 ,
<br />Piping Insulation 503.11 In accordance with Table 5-10, V
<br />Water Heaters 504.2 Automatic electric storage water heaters sl20 gallons and gas & oil-fired storage water heaters ../
<br /> s 75,000 BtuJh shall meet performance mlnlf'!lums In Table 5-11. Larger sized water heaters shall
<br /> meet minimums In Table 11-1 of Standard RS-9 after 111/92,
<br />Swimming Pools 504.2 Spas & heated pools must have covers. Non-commercial pools must have pump timer. N/A
<br />& Spas Gas spa & pool healers must have minimum thermal efficiency of 78%.
<br />Hot Water Pipe 504.4 Piping heat loss is limited to 17.5 Btulh linear foot of pipe for recirCUlating systems (see Table 5-12). V
<br />Insulation
<br />Water Fixtures 504.5 Water flow restricted to maximum of 3 gpm at. 80 psig; toilets maximum 3.5 gallon flush. V
<br /> Public lavatory fixture maximum flow of .5 gpm or ,5 gallon If has self-closing valve,
<br />Ughting 505.1 Ughtlng power budgets are listed In Table 5-13. Minimum Ballast Effieacy Factors are listed In Table 5-14. V
<br />
<br />Uo wall Allowable
<br />Uo roof 1 ceiling Allowable
<br />Uo lloor Allowable
<br />
<br />OTTV wall Allowable
<br />OTTV roof 1 ceiling Allowable
<br />
<br />Uo wall Actual
<br />Uo roof 1 ceiling Actual,
<br />Uo 1I00r Actual
<br />
<br />
<br />If complying under the provisions of S. 502.1, enter the combined Uo values for the entire envelope
<br />In this section.
<br />Uo envelope Allowable Uo envelope Actual
<br />
<br />OTTV wall Actual
<br />OTTV roof 1 celli Actual
<br />
<br />Compliance with Section 5 was demonstrated by a Prescriptive Measures methodology: .
<br />D 508,0 (a) Detached commercial buildings D 508.0 (b) Skyboxes or sports staaium buildings
<br />less than 100 square feet." that are used only seasonally. '
<br />
<br />I hereby certify thet the plans and speclficati,o[lS covered by the calculation are In compliance
<br />with the Florida E~Code . ' - ~
<br />PREPAREO BY: . ~41' ~tV/~ DATE: <-
<br />I hereby certify that th~::, 1'i!~tIl ~ J:I~~ergy Code. -
<br />OWNER/AGENT: <- . . -. DATE: $. ~~
<br />
<br />
|