<br />FLORIDA ENERGY EFFICIENCY CODE
<br />FOR BUILDING CONSTRUCTION
<br />Section 9 - Residential Point System Method
<br />Department of Community Affairs
<br />
<br />Climate Z9\les
<br />CENTRALGY 5 6
<br />
<br />OWNER:
<br />
<br />
<br />BUILDER:
<br />PERMITTING
<br />OFFICE:
<br />PERMIT ~
<br />NO,:~
<br />
<br />
<br />CLIMATE 4 rr;::r- 5 0 6 0
<br />ZONE: L:.J
<br />JU~ISDICTION ~
<br />NO" ~
<br />
<br />PROJECT NAME
<br />AND ADDRESS:
<br />
<br />'9, \_., (\
<br />...l..) t,~ ~" "~ . ~_ ..:.:....
<br />
<br />~
<br />o
<br />
<br />MULTIFAMILY ATTACHED 0
<br />SINGLE.FAMILY DETACHED 5ZI
<br />
<br />NEW CONSTRUCTION
<br />ADDITION
<br />
<br />IF MULTIFAMILY, NUMBER OF
<br />UNITS COVERED BY []JJ
<br />THIS SUBMITTAL
<br />
<br />CHECK IF THIS SUBMITTAL
<br />REPRESENTS A WORST CASE
<br />CONDITION. 0
<br />
<br />CONDITIONED ~ SO
<br />FLOOR AREA LJ.llJJ..U.QJ FT
<br />PREDOMINANT
<br />EAVE OVERHANG
<br />LE NGTH
<br />PORCH OVERHANG
<br />LENGTH
<br />
<br />rn.~ FT
<br />rn.D FT
<br />
<br />GLASS AREA AND TYPE
<br />CLEAR TINT,FILM,SOLAR SCREEN
<br />SINGLE. []JJJS11 SINGLE. ~ SQ.
<br />PANE FT PANE ~ FT
<br />DOUBLE. []JJJ SO DOUBLE- []JJJ SQ.
<br />~E FT ~E FT
<br />
<br /> NET WALL AREA AND INSULATION
<br />EXTERIOR MASONRY R = EXTERIOR FRAME R - EXTERIOR STEEL R = EXTERIOR LOG R =
<br />OJIJ] SO rn.D CILIiJQ] SO UTI] OJIJ] SO rn [IITD ~~, rn
<br /> FT ii, FT FT
<br />ADJACENT MASONRY R = ADJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG R =
<br />OJIJ] SO rn.o CIEITI SO ITliJ OJIJ] ~~ rn OJIJ] SO rn
<br /> FT \ ::' ~. FT FT
<br />
<br /> CEILING AREA AND INSULATION FLOOR TYPE AND INSULATION
<br />UNDER ATTIC R - SINGLE ASSEMBLY R - SLAB PERIMETER R = RA,ISED WD 0 CON 0 R =
<br />[[lli[E]so. rn OJIJ]so, rn ITIIJ FT OJ []]]]]SQ, rn
<br />" ' .."/ FT :, \.~ FT. FT
<br />DUCTS COOLING SYSTEM HEATING SYSTEM HVAC CREDITS HOT WATER SYSTEM HOT WATER CREDITS
<br />IN ca CENTRAL o ELECTRIC STRIP J:8J HEAT o CEILING FANS 1ZI ELECTRIC SOLAR: D.rn
<br />UNCONDITIONED
<br />SPACE R = o ROOM o NATURAL GAS PUMP l2J CROSS VENTILATION o NATURAL 3AS SJ. =
<br /> 0
<br />[]JJ ~l o PACKAGE TERMINAL o ROOM UNIT OR o OTHER o WHOLE HOUSE FAN o OTHER FUELS HEAT RECOVERY ICHECKI
<br />, 'ilL-.;:::.J AIR CONDITIONER PACKAGE TERMINAL FUELS DEDICATED .rn
<br />IN CONDITIONED o NONE o ATTIC RADIANT o NONE HEAT PUMP: 0
<br />SPACE R = o NONE HEAT PUMP BARRIER E F =
<br />rn,o SEER/EER = ern.1Q] COP/HSPFI ~ ~ o MULTIZONE EF= ,m NUMBER OF OJ
<br />AFUE = . , ) I ) BEDROOMS :
<br />
<br />INFIL TRA TION
<br />PRACTICE USED
<br />o 111 lXJ 112 0 #3
<br />
<br />PREPARE
<br />
<br />
<br />~ ~O x100= ~n)
<br />~ Ll~ L..l:2L::J.L::::J
<br />TOTAL AS.BUlLT POINTS TOTAL BASE POINTS CALCULATED E,P.1.
<br />CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS.
<br />
<br />Review of plans and specifications covered by this calculation indicates compliance with
<br />the Florida Energy Code, Before onstruction is completed, this building will be inspected
<br />for compliance in accordan i Seclio .908, F,S, eo
<br />
<br />BUILDING OFFICIAL:
<br />
<br />DATE
<br />
<br />
<br />9A PRESCRIPTIVE ME
<br />COMPONENTS SECTIO
<br />WINDOWS 904,1
<br />EXTERIOR & 904.1
<br />ADJACENT DOORS
<br />EXTERIOR JOINTS 904,1
<br />& CRACKS
<br />WATER HEATERS 904.2
<br />
<br />URES (must be met or exceeded by all residences.)
<br />REQUIREMENTS
<br />Maximum of 0,34 CFM er linear foot of 0 erable sash crack includes slidin lass doors.
<br />Maximum of 0,5 CFM per sq, ft, of door area: solid core, wood panel. insulated or glass doors only,
<br />
<br />
<br />CHECK
<br />
<br />To be caulked, gasketed, weatherstripped or otherwise sealed,
<br />
<br />SWIMMING POOLS 904.3
<br />& SPAS
<br />SHOWER HEADS 904,5
<br />HVAC DUCT 904,6
<br />CONSTRUCTION,
<br />INSULATION
<br />& INSTAllATION
<br />HVAC CONTROLS 904.7
<br />INSULATION 904.9
<br />
<br />Comply with efficiency requirements in Table 9.7A. Switch or clearly marked circuit breaker (electric)
<br />or cutoff as must be rovided, External or built.in heat tra re uired,
<br />Spas & heated pools must have covers (except solar heated), Non.commercial pools must have a
<br />um timer. Gas s a & 001 heaters must have minimum thermal efficienc of 78%.
<br />Water flow must be restricted to no more than 3 allons er minute at 80 PSIG.
<br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached,
<br />sealed, insulated and installed in accordance with the criteria of Section 904.6, Ducts in unconditioned
<br />space and air handlers located in attics must be Insulated to a minimum R.4,2 (R-6 after 1/1/92),
<br />
<br />Separate readily accessible manual or automatic thermostat for each system,
<br />Ceilings.Min. R.19, Common Walls. Frame R.11 or CBS R,3. Common Ceilings & Floors R.11.
<br />
|