My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
93-2910
Zephyrhills
>
Building Department
>
Permits
>
1993
>
93-2910
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 10:17:18 AM
Creation date
4/28/2006 11:15:16 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Building Department - Date
1/5/1993 12:00:00 AM
Permit #
93-2910
Building Department - Name
SOUTHSIDE CHURCH
Address
37737 C AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />tre <br /> <br />Ii"rFil(('j)IF~~~U(QIrNJt'\1L <br />[QI~~UcGlrNJ IFUrFilW~ <br /> <br />TOW)ON-ROGER) <br />ENGINEERING INC. <br /> <br />ENGINEERING. PLANNING, ENVIRONMENTAL PERMITTING <br /> <br />January 4, 1993 <br /> <br />Mr. David Rushlow, Pastor <br />Souths ide Church of Christ <br />37737 "c" Avenue <br />Zephyrhills, Florida 33541 <br /> <br />RE: Renovation of Medical Building <br />for new church <br /> <br />Dear Pasto~ Rushlow; <br /> <br />I have inspected the existing roof trusses in the building you are <br />renovating for a new church. Several trusses have been altered by <br />the previous building owner in order to provide a storage room in <br />the attic of the building. Alteration of these trusses was accom- <br />lished by removing the center two diagonal web members. Approxi- <br />mately 12 to 15 inches of the ends of the diagonal web members <br />together with the metal gusset plates are still in place. <br /> <br />An acceptable method of repair would be to remove all sheetrock <br />from the modified room area. Reconstruct the diagonal web members <br />by replacing them with 2 x 4 members overlapping the remaining ends <br />of the original members. The new members are to be connected to <br />the remaining ends by installing (2) 5/16" bolts with flat washers <br />at each overlap. All existing horizontal and vertical framing from <br />which sheetrock has been removed, can remain in place. <br /> <br />If you have any questions or encounter any difficulties during <br />repair of the trusses, please call me. Thank you. <br /> <br />Very Truly Yours, <br /> <br />d-'~~ <br /> <br />Gerald E. Towson, P.E. <br /> <br />Towson-Rogers Engineering, Inc. <br /> <br />GET/tg <br /> <br />cc: Mr. Roy Burnside <br /> <br />misc\southsid <br /> <br />5514 7TH STREET · ZEPHYRHILLS, FLORIDA 33540 813.788-0400 <br />
The URL can be used to link to this page
Your browser does not support the video tag.