<br />ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A:18 HEATING CREDIT MULTIPLIERS HCM <br />SYSTEM TYPE <br />----- ~_._----_..~-------~-----~----- <br />~ttic R.a.9ian!I?,<lfliElr~____~__ <br />Multizone <br /> <br />Natural Gas <br />LP Gas <br /> <br />HCM <br />HCM <br />AFUE <br />HCM <br />----- <br />HCM <br /> <br />._________ ..._____JiE~TING CREDIT MULTIPLIERS (HCM) <br />.98 <br /> <br />_______...__ ____.90 _____. ~ <br /> <br />.68-.72 <br />.61 <br />.77 <br /> <br />.73-.77 <br />.~.- <br />.56 <br />--.---- <br />.72 <br /> <br />.78- .82 <br />.53 <br />.67 <br /> <br />.83-.87 <br />.50 <br />.63 <br /> <br />.88-.92 <br />.47 <br />.60 <br /> <br />.93&~_ <br />.44 <br />.57 <br /> <br />6A-19 COOLING CREDIT MULTIPLIERS CCM) <br />1-.,.' SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) <br />_C~iIiD.9f ans t,.- .86' -- <br />_Cros?lJentila!iol!...~_~_ ----- .90' 'Credit may be taken for only <br />._~----------------- <br />Whole House Fan --- -- n .90' ane af these system types cancurrently. <br />Multilane .95 <br />-- -..- .---------- _m ----------- ------------- <br />Attic Radiant Barrier .95 <br /> <br />6A.20 HOT WATER CREDIT MULTIPLIERS HWCM <br />SYSTEM TYPE <br />---------.-.-------..-.- <br /> <br />Dedicated Heat Pump <br /> <br />With <br />.------- <br />HWCM <br />EF <br />HWCM <br />._._--~.__._- <br /> <br />_.._.___ __ ----.!iQT WAT.ER CREDIT MULTIPLIERS (HWCM) <br />Air c'.~"""- -1. - --~~fa~ '--. - <br /> <br />2.0-2.49 2.5-2.99 - 3.0-3.49 "i-_~2~1JQ..--~-~ <br />.44 .35 _ .29 _ ______Jli___ <br />A HWMMUST BE-USED-INCONJUNCTION wITH ALL-HWCM. SEE TABLE -i3ATIY MEAN-SENERGYFACTOR - <br /> <br />Heat Recovery Unit <br /> <br />6A.21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606.1 COMPLY WITH ALL INFilTRATION PRESCRIPTIVES. <br />Wlndaws 606.1 Maximum of 0.34 CFM per linear foot af operable sash crack (includes sliding glass doors). "-.----- <br />Exterior & Adiacent Doors 606.1 Maximum of 0.5 CFM oer sa. ft. of door area; salid care, wood oanel, insulated ar alass daars only. -.- <br />Exterior Joints & Cracks 606.1 To. be caulked, aasketed, weatherstriooed ar atherwise sealed. <br />PRACTICE #2 606.2 COMPLY WITH #1 AND THE FOLLOWING: <br />Exterior Walls and Floors To.o olate oenetratians sealed. Infiltratian barrier installed. Sale olate/floor iaint caulked ar sealed. <br />Exterior Walls & Ceilinqs Penetratians, iaints and cracks an interior surface caulked, sealed ar aasketed. <br />Ductwark Ductwark in uncanditianed soace must be sealed. <br />Fireolaces Eauiooed with outside cambustion air, daars, and flue damoers. <br />Exhaust Fans Equipped with dampers. Cambustian devices see 606.1.A.2 <br />Combustion Appliances Be in uncanditianed space (except direct vent), draw air from uncanditianed space, exhaust to. autside. <br /> CookinQ appliances shall be dampered and use intermittent ianition. <br />PRACTICE #3 606.2 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinas Infiltratian barrier installed. <br />Interior Walls To.o oenetratians sealed ar iaints & cracks on interiar walls caulked, sealed or gasketed. <br />Recessed Liahts Sealed from canditianed & insulated from ventilated attic soaces. r <br />DUctwork All ductwork located in conditioned space. I <br /> <br />6A-22 OTHER PRESCRIPTIYE MEASURES Imust be met or exceeded bv all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Camply with efficiency requirements in Table 6-12. Switch ar clearly marked circuit breaker (electric) <br /> ar cutaff laas) must be nrovided. External ar built-in heat tran renuired. <br />Swimming Pools & Spas 612.1 Spas & heated paals must have cavers (except salar heated). Nan-cammercial paals must have <br /> a Dump timer. Gas soa & 000.1 heaters must have a minimum thermal efficiencv af 78%. <br />Shower Heads 612.1 Water flow must be restricted to no mare than 3 aallons ner minute at 80 PSIG. <br />HVAC Duct Construction 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />Insulation & Installation sealed, insulated, and installed in accardance with the criteria af Section 904.6. Duct in uncanditianed <br /> space and air handlers located in attics must be insulated to. a minimum of R-6. Air handlers shall not <br /> be installed in attics unless in mechanical claset. <br />. HY AgJ~Qf:!!r'()I~_~_ 607.1 ~~arate readily accessible manual or automatic thermostat for each system. ~-_._- <br />Insulation 604.1 602.1 Ceilinas-Min. R-19. Cammon walls-Frame R-11 ar CBS R-3 bath sides. Common ceilina &. flaors R-11. <br /> <br />-6- <br />