<br />WINTER POINT MULTIPLIERS (WPM) <br /> <br />CLIMATE ZONES 4 .5 6 <br /> <br />6A.10 WINTER OVERHANG FACTORS IWOF! , <br />J OH RATIO I .00-.11 T ,12-.17 .18-.26 I .27-.35 .36-.46 I .47-,57 ,58-.70 .71-,83 I .84-1.18 11.19-1.72 1.73-2.73 I 2,74+ <br /> SINGLE PANE GLASS <br />N 1.00 1,03 1.05 1,08 1.10 1,13 1,15 1.18 1,20 1.24 1.29 1.34 <br />NElNW 1.00 1.07 1.10 1.15 1,20 1.25 1.30 1.35 1.39 1,50 1,59 1,67 <br />ENV 1.00 .71 ,57 .19 -.20 -.65 -1.05 -1.48 -2.03 -3.01 -4.06 -5.04 <br />SElSW 1.00 ,93 .90 .80 .68 .54 ,39 .22 .05 -.33 -.71 -1.01 <br />Ga: S 1.00 .95 ,92 .83 .70 ,54 .36 .13 -.13 -,70 -.98 -1.09 <br />~[ DOUBLE PANE GLASS <br />N 1.00 1.05 1.07 1,11 1.14 1,18 1.21 1.24 1.28 1.34 1.40 1.47 <br />NElNW 1.00 1.11 1.16 1,24 1,32 1.41 1.48 1.56 1.63 1.80 1.94 2.08 <br />ENV 1.00 ,88 ,82 .66 .50 .31 .15 -.03 -.26 -.66 -1,10 -1.50 <br />SElSW 1,00 .95 ,92 ,85 .76 ,65 ,54 .41 .28 -.01 -.30 -,52 <br />S 1.00 .96 .94 .87 ,78 ,65 .51 .33 .13 -,30 -.51 -.60 <br />OH LENGTH* 011, 111, 1%11, 211. 311, 3%11. 4%11. 5%11, 6%11, 9%11, 1411. 2011.+ <br /> 'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT. BELOW THE OVERHANG. <br /> <br />6A-l1 WALL WINTER POINT MULTIPLIERS WPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6,8 5,3 <br />2.5 2.1 <br />2.0 1.8 <br />1,8 1.6 <br />1.1 1.0 <br />.7 .7 <br /> <br />R-V ALUE <br />0-6.9 <br />7-10.9 <br />11-12,9 <br />13-18.9 <br />19-25,9 <br />26&U <br /> <br />STEEL <br />EXT ADJ <br />9.4 6,7 <br />4.4 3,3 <br />3,3 2.6 <br />3.0 2.4 <br />2.6 2,2 <br />1.4 1.2 <br /> <br /> <br />CONCRETE BLOCK' <br />INT. INSULATION <br />NORMAL WT. <br />EXT ADJ <br />6.0 3.1 <br />3.8 2,3 <br />2.9 1,9 <br />2,3 1.5 <br />1.5 1.1 <br />.8 .7 <br />.5 .5 <br /> <br /> <br />6A.12 DOOR WINTER POINT MULTIPLIERS 6A.13 CEILING WINTER POINT MULTIPLIERS lWPMl <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOFING <br /> R.VALUE WPM R-V ALUE WPM CEILING TYPE <br />WOOD 7.6 5,9 19-219 1.0 10-10.9 1.8 R-VALUE DROPPED EXPOSED <br /> 22-25.9 .9 11-12.9 1.6 10-13.9 1.2 1.3 <br />INSULATED 5.1 4.0 26-29,9 ,7 13-18,9 1.5 14-20.9 .7 .7 <br /> 30-37.9 ,6 19-25.9 1.1 21 &Uo .4 ,3 <br /> 38 & Uo .4 26-29,9 ,6 <br /> 11) R. Iln 4 <br />6A-14 FLOOR WINTER POINT MULTIPLIERS IWPMl <br />SLAB-QN.GRADE '.f; RAISED HO RAISED WOOD2 <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wi UNDER ADJACENT <br />iii.... CONSTRUCTION FLOOR INSULATION <br />R-VALUE WPM if.. R-VALUE WPM R-VALUE WPM WPM WPM <br />0-2.9 2.5 0-2,9 4.0 f/ 0-6.9 7.9 N/A 5.3 <br />3-4.9 -1.7 3-4.9 1,8 7-10.9 2,1 .7 2.1 <br />5-6.9 -2.4 i 5-6,9 1,1 1/ 11-18.9 1.5 .5 1.8 <br />7 !l.lln -')7 i 7 !I. lJn R Iii.: ~lnQ ,- 1(1' <br /> <br />WPMI <br /> <br />6A-15 INFILTRATION WINTER POINT MULTIPLIERS (WPMI 6A-16 DUCT MULTIPLIERS DM <br /> <br />SUPPLY DUCTS IN <br />ONDITIONED SPACE' <br /> <br /> <br />RETURN DUCTS <br />IN UNCONDITIONED SPACE <br />1.14 <br />1,10 <br />1.09 <br />1.10 <br />1.07 <br /> <br />RETURN DUCTS <br />IN CONDITIONED SPACE <br />1.10 <br />1.07 <br />1.06 <br />1.00 <br />1.00 <br /> <br />INFILTRATION PRACTICE WPM <br />lSEE TABLE 9Pl <br />PRACTICE #1 6.2 <br />PRACTICE #2 4.1 <br />/11 ?? <br /> <br />SUPPLY DUCTS IN <br />UNCONDITIONED SPACE <br /> <br />6A-17 HEATING SYSTEM MULTIPLIERS IHSMl <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS IHSM\ <br />Central Heat HSPF 6.40-6.79 6,80-6.89 6.90-7.39 7.40-7.89 7.90-8,39 8.40-8.89 8,9,9,39 9,4-9.89 <br />Pump Units HSM .53 ,50 .49 .46 .43 .41 .38 .36 <br /> HSPF 9.90-10,39 10,40-10.89 10.90-11,39 11.40-11.89 11.90-12,39 12.40 & un <br /> HSM ,34 .33 .31 .30 ,29 ,28 <br />PTHP COP 2.50-2.69 2.70,2,89 2,90-3.09 3.10-3.29 3,30-3.49 3.50-3,69 3.70-3,89 3.90-4.19 <br /> HSM ,38 .37 .34 ,32 .30 ,29 .27 .26 <br />Electric Strin 1,0 <br />Gas & Other Fuels 1,0 (See Table 6A-18lor Credit Multiolierl <br />MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF. SINGLE PKG. 6.6 HSPF. WATER SOURCE 3.8 COP, GROUND WATER SOURCE 3.4 COP, PTHP 2.5-2.7 COP. <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-V ALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />.5- <br />