Laserfiche WebLink
<br />WINTER POINT MULTIPLIERS (WPM) <br />~ <br /> <br />CLIMATE ZONES '4 '5 6 .' <br /> <br />6A.l0 WINTER OYERHANG FACTORS (WOFI <br /> ~ OH RATIO .00-,11 ,12-,17 .18-.26 .27-.35 I .36-.46 ,47-,57 I .58-.70 I .71-,83 I .84-1.18 1.19-1.72 1.73-2.73 2.74+ <br /> SINGLE PANE GLASS . <br /> N 1.00 1.03 1.05 1,08 1.10 1.13 1.15 1.18 1.20 1.24 1.29 1.~4 <br /> NE/NW 1.00 1.07 1.10 1.15 1,20 1.25 1.30 1.35 1.39 1.50 1.59 1.67 <br /> Em 1.00 .71 ,57 .19 -.20 -.65 -1.05 -1.48 -2,03 -3.01 -4.06 -5.04 <br />>- SElSW 1.00 .93 .90 .80 .68 ,54 .39 .22 .05 -.33 -.71 -1.01 <br />lEI <br />I-a: S 1.00 .95 .92 .83 .70 ,54 .36 .13 -.13 -.70 -.98 -1.09 <br />~[ DOUBLE PANE GLASS <br />N 1.00 1.05 1.07 1.11 1.14 1.18 1.21 1.24 1.28 1.34 1.40 1.47 <br />NElNW 1.00 1.11 1.16 1.24 1.32 1.41 1,48 1.56 1.63 1.80 1,94 2.08 <br />Em 1.00 .88 .82 .66 ,50 .31 .15 -,03 -.26 -.66 -1.10 -1.50 <br />SElSW 1.00 .95 .92 .85 .76 .65 ,54 .41 .28 -.01 -.30 -.52 <br />S 1.00 ,96 ,94 .87 .78 .65 .51 .33 .13 -.30 -.51 -.60 <br />OH LENGTH' 011. 111. 1%11. 211. 311, 3V211, 4%11, 5%11, 6%11, 9%11. 1411. 2011.+ <br /> 'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT, BELOW THE OVERHANG. <br /> <br />6A.ll WALL WINTER POINT MULTIPLIERS WPM <br />FRAME <br /> <br />R-YALUE <br />0-6.9 <br />7-10,9 <br />11-12.9 <br />13-18.9 <br />19-25.9 <br />26& U <br /> <br />WOOD <br />EXT ADJ <br />6.8 5.3 <br />2.5 2,1 <br />2.0 1.8 <br />1.8 1.6 <br />1.1 1.0 <br />.7 .7 <br /> <br />STEEL <br />EXT ADJ <br />9.4 6.7 <br />4.4 3,3 <br />3.3 2.6 <br />3.0 2.4 <br />2,6 2.2 <br />1.4 1.2 <br /> <br /> <br />CONCRETE BLOCK' <br />INT. INSULATION <br />NORMAL WT. <br />EXT ADJ <br />6.0 3.1 <br />3.8 2.3 <br />2.9 1.9 <br />2.3 1.5 <br />1.5 1.1 <br />.8 ,7 <br />.5 .5 <br /> <br /> <br />6A.12 DOOR WINTER POINT MULTIPLIERS <br />DOOR TYPE EXTERIOR ADJACENT <br />WOOD 7.6 5,9 <br />INSULATED 5.1 4.0 <br /> <br />WPMI <br /> <br />6A.13 CEILING WINTER POINT MULTIPLIERS (WPM I <br />UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOFING <br />R-YALUE WPM R-Y ALUE WPM CEILING TYPE <br />19-219 1,0 10-10.9 1.8 R-YALUE DROPPED EXPOSED <br />22-25.9 .9 11-12.9 1.6 10-13.9 1,2 1.3 <br />26-29.9 .7 13-18.9 1.5 14-20.9 .7 .7 <br />30-37,9 ,6 19-25.9 1.1 21 & UP .4 .3 <br />38 & UP .4 26-29.9 .6 <br /> 30 & Uo .4 <br /> <br />6A-14 FLOOR WINTER POINT MULTIPLIERS (WPMI <br />SLAB-QN-GRADE III: RAISED RAISED WOOD2 <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wI UNDER ADJACENT <br />i} CONSTRUCTION FLOOR INSULATION <br />R.YALUE WPM '}} R-YALUE WPM R-Y ALUE WPM WPM WPM <br />0-2.9 2.5 0-2.9 4.0 0-6.9 7.9 N/A 5.3 <br />3-4.9 -1.7 } 3-4.9 1.8 7-10.9 2,1 ,7 2.1 <br />5-6.9 -2.4 :i 5-6.9 1.1 11-18,9 1,5 .5 1.8 <br />7 & Uo -?7 7 Po. Iln R HlPo.IJnq ::! 10 <br /> <br />6A-15 INFILTRATION WINTER POINT MULTIPLIERS (WPMI 6A-16 DUCT MULTIPLIERS DM <br /> <br />INFILTRATION PRACTICE WPM <br />(SEE TABLE 9Pl <br />PRACTICE #1 6.2 <br />PRACTICE #2 4.1 <br /> 2,2 <br /> <br />SUPPLY DUCTS IN <br />UNCONDITIONED SPACE <br /> <br /> <br />RETURN DUCTS <br />IN UNCONDITIONED SPACE <br />1.14 <br />1.10 <br />1.09 <br />1.10 <br />1.07 <br /> <br />RETURN DUCTS <br />IN CONDITIONED SPACE <br />1.10 <br />1.07 <br />1.06 <br />1.00 <br />1.00 <br /> <br />SUPPLY DUCTS IN <br />CONDITIONED SPACE' <br /> <br />6A-17 HEATING SYSTEM MULTIPLIERS (HSMI <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS 'HSMI <br />Central Heat HSPF 6.40-6.79 6.80-6,89 6.90-7.39 7.40-7.89 7.90-8,39 8.40-8.89 8.9-9.39 9.4-9.89 <br />Pump Units HSM .53 .50 .49 .46 .43 .41 .38 .36 <br /> HSPF 9,90-10.39 10.40-10,89 10.90-11.39 11.40-11,89 11.90-12.39 12.40 & uo <br /> HSM .34 .33 .31 .30 .29 .28 <br />PTHP COP 2,50-2.69 2.70-2.89 2,90-3.09 3.10-3.29 3.30-3.49 3.50-3.69 3.70-3.89 3.90-4.19 <br /> HSM .38 ,37 .34 .32 .30 .29 .27 .26 <br />Electric Strio 1.0 <br />Gas & Other Fuels 1.0 (See Table 6A-18 for Credit Multiplier) <br />MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6,8 HSPF, SINGLE PKG, 6,6 HSPF, WATER SOURCE 3.8 COP, GROUND WATER SOURCE 3.4 COP, PTHP 2,5.2.7 COP, <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2,1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3,1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION, <br /> <br />.5. <br />