<br />'SUMMER POINT MULTIPLIERS (SPM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-1 SUMMER OVERHANG FACTORS ISOFl FOR SINGLE AND DOUBLE PANE GLASS. . <br />~r OH RATIO ,00-.11 ~ ,12-,17 ,18-,26 ,27-.35 .36-,46 .47-,57 ,58-,70 .71-,83 ,84-1,18 1.19-1,72 1.73-2.73 2.74+ <br />N 1.00 .94 .91 .87 ,83 .79 ,76 ,72 ,69 ,63 ,56 ,50 <br />NE/NW 1.00 .94 .91 ,85 ,79 ,72 ,68 ,63 ,58 ,50 ,40 ,36 <br />I-a: EIW 1,00 ,95 ,92 ,85 ,78 ,70 ,64 .58 .52 <br />~o .42 .33 ,26 <br />ml SE/SW 1.00 ,93 ,90 ,81 ,72 ,62 ,55 ,49 .42 ,33 ,27 ,22 <br />S 1.00 ,91 ,87 ,77 ,67 ,57 ,50 .45 ,39 ,32 ,28 ,25 <br />f'll-l :tJ~TI-l. Oft, 1 ft, 1V.ft. 2ft. 3ft, 3% ft. 4% ft. 5%ft, f1%ft Q%ft 14ft ?Oft+ <br /> 'To select bv Overhano Lenoth, no oart of olass shall be more than 8 ft, below the overhano, <br /> <br />l' <br /> <br />6A-2 WALL SUMMER POINT MULTIPLIERS SPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6.4 2.2 <br />2,3 ,8 <br />1,9 .7 <br />1,7 .6 <br />1.0 ,3 <br />,6 ,2 <br /> <br />R-V ALUE <br />0-6.9 <br />7-10.9 <br />11-12,9 <br />13-18,9 <br />19,25.9 <br />26& U <br /> <br />STEEL <br />EXT ADJ <br />8.9 2.9 <br />4,1 1.3 <br />3,0 1.0 <br />2,8 0,9 <br />2,4 0,8 <br />1,3 0,4 <br /> <br /> <br />CONCRETE BLOCK1 <br />INT. INSULATION EXT.INSUL <br />NORMAL WT. NOR. WT. <br />EXT ADJ EXT <br />2,5 ,9 2.5 <br />1.4 .7 ,7 <br />1.0 ,6 ,3 <br />,8 ,4 ,1 <br />.4 ,3 0 <br />,2 ,2 <br />,1 .1 <br /> <br /> <br />6A-3 DOOR SUMMER POINT MULTIPLIERS <br />DOOR TYPE EXTERIOR ADJACENT <br />WOOD 7,2 2.4 <br />INSULATED 4,8 1,6 <br /> <br />SPM) <br /> <br />6A-4 CEILING SUMMER POINT MULTIPLIERS (SPMI <br />UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOFING <br />R-V ALUE SPM R.VALUE SPM CEILING TYPE <br />19-219 1.1 10-10,9 3,0 R-V ALUE DROPPED EXPOSED <br />22-25,9 .9 11-12,9 2,7 10-13,9 3.0 3,3 <br />26-29.9 .7 13-18.9 2.4 14-20,9 2,0 2,1 <br />30-37,9 ,6 19-25,9 1,8 21 & Up 1.4 1,3 <br />38 & UP ,4 26-29,9 1,1 <br /> ::lOR-lln OQ <br /> <br />6A-5 FLOOR SUMMER POINT MULTIPLIERS (SPMI <br />SLAB-QN-GRADE RAISED RAISED WOOD2 <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wI UNDER ADJACENT <br />........) CONSTRUCTION FLOOR INSULATION <br />R-V ALUE SPM R-V ALUE SPM R.VALUE SPM SPM SPM <br />0-2,9 -31.9 0-2,9 -1,0 0-6,9 0,9 N/A 5,3 <br />3-4,9 -31,8 FF 3-4,9 -1,7 7-10.9 -1,1 -2,8 2,1 <br />5-6,9 -31,7 5-6,9 -1,7 11-18,9 -1,0 -2,2 1,8 <br />7 & Uo -31.6 7 & Uo -1.7 19& UO -OQ -1,8 1,0 <br /> <br /> <br />6A.7 DUCT MULTIPLIERS DM <br /> <br />13.8 <br />10,9 <br />7. <br /> <br />SUPPLY DUCTS IN <br />UNCONDITIONED SPACE <br /> <br /> <br />RETURN DUCTS <br />IN UNCONDITIONED SPACE <br />1,14 <br />1,10 <br />1,09 <br />1,10 <br />1,07 <br /> <br />RETURN DUCTS <br />IN CONDITIONED SPACE <br />1,10 <br />1,07 <br />1,06 <br />1,00 <br />1,00 <br />1 <br /> <br />SUPPLY DUCTS IN <br />CONDITIONED SPACE' <br /> <br />6A-8 COOLING SYSTEM MULTIPLIERS (CSMI <br />SYSTEM TYPE COOLING SYSTEM MULTIPLIERS ICSMl <br />Ceotral Units (SEER) Ratina 7,5-7,9 8.0-8.4 8,5-8,8 8,9-9,4 9,5-9,9 10,0-10.4 10.5-10,9 11,0-11.4 11,5-11,9 12,0-12.4 <br />CSM ,45 .43 ,40 ,38 ,36 ,34 ,32 ,31 ,30 .28 <br />PTAC & Room Units (EER) Ratina 12.5-12,9 13.0-13.4 13.5-13,9 14,0-14.4 14,5,14.9 15,0-15.4 15,5-15,9 16,0-16.4 16,5-16,9 17,0-17.4 17,5 & Uo <br />CSM .27 ,26 ,25 ,24 ,24 .23 .22 ,21 .21 ,20 ,19 <br />MINIMUMS: CENTRAL UNITS-AIR COOLED SPLIT SYSTEM 10,0 SEER, SINGLE PKG, 9.7 SEER, GROUND WATER COOLED 11,0 EER. PTAG-SEE TABLE 6.3, <br /> <br />6A-9 HOT WATER MULTIPLIERS (HWMI <br />SYSTEM TYPE HOT WATER MULTIPLIERS (HWM <br />Electric Resistance EF .80-,81 ,82-,83 ,84-,85 ,86-,87 ,88-,90 ,91-.93 ,94-,96 ,97 & Up <br />HWM 4183 4081 3984 3891 3803 3678 3560 3450 <br />Natural Gas EF ,43-,47 .48-.49 ,50.51 .52-,53 ,54-.55 ,56-.57 ,58-.59 ,60,,61 ,62-,63 ,64-,65 ,66 & Uo <br />HWM 3098 2775 2664 2562 2467 2379 2297 2220 2138 2081 2018 <br />Lo Gas HWM 4195 3758 3608 3469 3340 3221 3110 3007 2910 2819 2733 <br />Solar EF 1,0-1.9 2,0-2,9 3,0-3,9 4,0-4,9 5.0 & Up <br />HWM R4 .42 .28 .21 .15 <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2,1 OF APPENDIX C, 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3,1 OF APPENDIX C, 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION, <br /> <br />,3- <br />