Laserfiche WebLink
<br />05200 Features & Specifications <br /> <br /> <br />..J + <br />w <br />z t <br />< <br />0. <br />..J 12 TO <br />0 27V DC <br />~ ~ <br />z <br />0 <br /><> <br /> <br />REMOTE TEST SWITCH <br /> <br />2-Wire Class B <br /> <br />Features: <br />Separate Detector and Base Design <br />Permits the same detector to be used with both 2- and 4- wire <br />bases. Features quick-disconnect ease and positive-lock <br />assembly stability. <br /> <br />Selectable Alarm Current (2-Wire Model) <br />Compatible with a wide range of U.L. Listed controls. <br /> <br />1350F Heat Sensor Option <br />Specify HD option when ordering. <br /> <br />Universal Mounting <br />Allows connection to single and double gang outlet and switch <br />boxes, as well as standard 4" square and octagonal type boxes. <br />May also be connected to surface mounted Wire mold type <br />raceways. <br /> <br />Dust Proof Protection <br />Sealed electronics permit drafty "plenum" ceiling applications <br />without concern for unwanted alarms due to "pull-through" dust <br />caused by pressure differentials. <br /> <br />Tamper Protection <br />No concern about forgetting to replace the detector. In/Out <br />wiring results in a fail-safe trouble signal with detector removal. <br /> <br />Vandal Protection <br />Detector securely latched to base with two point tie-down. <br /> <br />Specifications: <br />Alarm Condition <br />2:Wi@: SCR switch. Selectable alarm current. <br />4-Wire: Mechanical relay. Dry contacts rated 3 Watts, 0.125 <br />Amps, 28 VDC, resistive load, <br /> <br />Ordering Information <br /> <br />1) DS200 <br /> <br />Detector head only (requires <br />base ). <br />Detector head with 1350F Heat <br />Sensor (requires base). <br />Base, 2-Wire. <br />Base, 4-Wire. <br />DS200 with MB200-2W Base. <br />DS200 with MB200-4W Base. <br />DS200HD with MB200-2W Base, <br />DS200HD with MB200-4W Base. <br /> <br />DS200HD <br /> <br />MB200-2W <br />MB200-4W <br />DS200-2W <br />DS200-4W <br />DS200HD-2W <br />DS200HD-4W <br /> <br />2) EOL200 End-Ot-Line Module tor 4 Wire <br />Systems. <br />Call for our latest 2-wire cross listing. <br /> <br />PIN 18867 Rev,L 8189 <br /> <br /> <br />+ <br /> <br />rALARM{ <br />LOOP <br />12 TO <br />27VDC <br />... <br /> <br />TYPICAL <br /> <br />LAST <br /> <br />- <br />CONTROL <br /> <br />REMOTE TEST SWITCH <br /> <br />4-Wire Class B <br /> <br />Power Requirements <br />Standby Voltage: <br /> <br />Maximum RMS Ripple: <br />Standby Current: <br />Alarm Current: <br /> <br />2-Wire = 8.5 to 29.7 VDC <br />4-Wlre = 10 to 27 VDC <br />Less than 25% of DC Input. <br />80 micro-amps (~a). <br />2-Wire = Consult MB200 series <br />installation instructions #19578. <br />4-Wire = 25 ma @ 12 VDC. <br />36 ma @ 24 VDC. <br />200 ~a max (for 3 sec, after initial <br />power applied.) <br />15 seconds maximum. <br />4-Wire mechanical relay contacts <br />rated 3 Watts, 0.125 Amps, 28 VDC, <br />DC resistive load, <br /> <br />Start-Up Current: <br /> <br />Power-Up Time: <br />Alarm Contact Rating: <br /> <br />Sensitivity <br />Factory calibrated for nominal 3% gray smoke obscuration. <br /> <br />Infrared Source Pulse Format <br />300 micro-second wide pulse every two seconds. At nominal 3% <br />threshold obscuration, pulse speed increases four times (4X). <br />Alarm initiated after 5 consecutive pulses if still above threshold. <br />Automatic pulse count reset if obscuration drops below nominal <br />3% threshold before alarm initiated. <br /> <br />Power and Alarm Indicators <br />Two annunciator LEDs located close to the base on opposite <br />sides of the detector are standard. LED1 flashes briefly every <br />two seconds to verify normal operation of internal infrared <br />source. LED2 normally OFF, but latches ON in the event of an <br />alarm; standard reset with power interrupt. <br /> <br />Remote Alarm Indicator <br />Optional remote alarm LED circuit available. Up to 100 ma <br />allowed in remote circuit using 2-Wire base; 80 ma with 4-Wire <br />base. <br /> <br />Full Function Test <br />Individual detector alarm using a magnet in conjunction with a <br />built-in internal reed switch. <br />Multiple detector alarm using optional N.O. switch installed <br />between terminal "T" and ground at any base, <br /> <br />Radio Frequency Interference <br />No alarm or set-up on critical frequencies in the range from 26 to <br />900 MHz using a 10 Watt transmitter located 4 ft. (1.2 m) from <br />the unit or attached wiring under test. <br /> <br />Humidity <br />o to 95% R.H.; Non-condensing. Withstands Humidity Shock <br />testing. <br /> <br />Temperature Range <br />+320F to + 1200F (+ooC to +490C) Tested. <br />+320F to +1 oooF (+ooC to +380C) Normal Operating, <br />For Underwriters' Laboratories Certificated installations, the <br />operating temperature ra~ is +320 to + 1200F (OOC to +490C). <br />