Laserfiche WebLink
<br />: ~:SU~MER paiNT MU.LTIPLIERS (SPM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />IA-1 SUMMER OVERHANG FACTORS (SOF) FOR SINGLE AND DOUBLE PANE GLASS. <br />~r OH RATIO ,()()",11 .12-,17 ,18-,26 ,27-,35 ,36-,46 .47-,57 .58-.70 .71-.83 ,84-1.18 1.19-1,72 1,73-2,73 2.74+ <br />N 1.00 .94 ,91 .87 .83 .79 .75 .72 .69 ,62 ,56 ,50 <br />NE/NW 1,00 ,94 .91 ,85 .79 ,72 .68 .63 .58 ,50 ,40 ,36 <br />t;~ E!W 1.00 .95 ,92 ,85 ,78 .70 .64 ,58 .52 ,42 ,33 .26 <br />wO <br />~l SE/SW 1,00 .93 ,90 .81 .72 ,62 .55 .49 .42 ,33 ,27 ,22 <br />S 1.00 .91 .87 ,77 .67 ,57 ,50 .45 ,39 ,32 ,28 .25 <br />IH* nit 1 ft 11j,ft ?ft ~ft 3% fl. ,41;,ft <;1/"1I R1/.1t Ql/.,It 14ft ?Oft... <br /> 'To select bv Overhann Lenath no nart of nlass shall be more than 8 ft. below the overhano. <br /> <br />6A-2 WALL SUMMER POINT MULTIPLIERS SPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6.4 2,2 <br />2.3 ,8 <br />1,9 .7 <br />1.7 .6 <br />1.0 .3 <br />.6 .2 <br /> <br />R-VALUE <br />0-6.9 <br />7-10.9 <br />11-12,9 <br />13-18,9 <br />19-25,9 <br />26& U <br /> <br />STEEL <br />EXT ADJ <br />8.9 2.9 <br />4.1 1.3 <br />3,0 1.0 <br />2.8 0.9 <br />2.4 0,8 <br />1.3 0.4 <br /> <br /> <br />CONCRETE BLOCK1 <br />INT. INSULATION <br />NORMAL WT. <br />EXT ADJ <br />2,5 ,9 <br />1.4 ,7 <br />1.0 ,6 <br />.8 .4 <br />.4 .3 <br />.2 .2 <br />.1 ,1 <br /> <br /> <br />6A-3 DOOR SUMMER POINT MULTIPLIERS <br />DOOR TYPE EXTERIOR ADJACENT <br />WOOD 7.2 2.4 <br />INSULATED 4,8 1.6 <br /> <br />SPM) <br /> <br />6A-4 CEILING SUMMER POINT MULTIPLIERS (SPMl <br />UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF <br />R-VALUE SPM R-VALUE SPM CEILING TYPE <br />19-21,9 1.1 10-10.9 3.0 R-VALUE DROPPED EXPOSED <br />22-25,9 ,9 11-12.9 2.7 10-13,9 3.0 3,3 <br />26-29.9 .7 13-18,9 2.4 14-20,9 2.0 2,1 <br />30-37.9 ,6 19-25.9 1.8 21 & UD 1.4 1.3 <br />38 & UD .4 26-29.9 1.1 <br /> ~o R. Un 00 <br /> <br /> <br />RAISED W0002 <br />POST OR PIER STEM WALL wi UNDER <br />CONSTRUCTION FLOOR INSULATION <br />SPM SPM <br />0.9 -5.8 <br />-1.1 -2,8 <br />-1.0 -2.2 <br /> <br />ADJ~CENT <br /> <br />SPM <br />5.3 <br />2,1 <br />1,8 <br /> <br /> 6A.7 DUCT MULTIPLIERS IDM) <br /> RETURN DUCTS RETURN DUCTS <br /> R-VALUE IN UNCONDmONED SPACE IN CONDmONED SPACE <br /> SUPPLY DUCTS IN 4.2-5,9 1,14 1.10 <br /> UNCONDmONED SPACE 6,0-6.6 1.10 1,07 <br /> 6.7 & UP 1,09 1.06 <br /> SUPPLY DUCTS IN 4,2-5.9 1.10 1.00 <br /> CONDITIONED SPACE' 6,0-6.6 1,07 1.00 <br /> 607 & UD 1 nR 1.00 <br />6A-8 COOLING SYSTEM MULTIPLIERS ICSMl <br />SYSTEM TYPE COOLING SYSTEM MULTIPLIERS ICSMl <br />Central Units (SEER) Ratinn 7.5-7,9 8.0-8.4 8,5-8.8 8.9-9,4 9,5-9.9 10.0-10.4 10,5-10,9 11.0-11.4 11.5-11,9 12,0-12.4 <br />CSM .45 .43 .40 .38 .36 ,34 .32 ,31 .30 ,28 <br />PTAC & Room Units (EER) Ratinn 12,5-12.9 13.0-13.4 13.5-13.9 14.0-14.4 14,5-14.9 15.0-15.4 15,5-15,9 16,0-16.4 16.5-16,9 17.0-17.4 17,5 & UP <br />CSM ,27 .26 .25 .24 .24 .23 ,22 ,21 .21 .20 ,19 <br />MINIMUMS: CENTRAL UNITS-AIR COOLED SPLIT SYSTEM 10.0 SEER. SINGLE PKG. 9.7 SEER. GROUND WATER HEAT PUMP 11.0 EER PTAC-SEE TABLE 6-2 <br /> <br />6A~ INFILTRATION SUMMER POINT MULTIPLIERS (SPM) <br />INFILTRATION PRACTICE SPM <br />SEE TABLE 6A-21 <br />PRACTICE #1 13.8 <br />PRACTICE #2 10.9 <br /> <br />6A-9 HOT WATER MULTIPLIERS IHWM\ <br />SYSTEM TYPE HOT WATER MULTIPLIERS IHWM <br />Electric Resistance . EF .80-.81 .82-.83 ,84-.85 ,86-,87 ,88-.90 .91-.93 ,94-.96 .97 & UP <br />HWM 3879 3785 3695 3609 3527 3411 3302 3200 <br />Natural Gas EF .43-.47 I ,48-.49 .50-.51 ,52-,53 .54-,55 ,56-,57 .58-.59 .60-.61 .62-.63 ,64-.65 .66 & Up <br />HWM 2974 I 2664 2558 2459 2368 2284 2205 2132 2063 1998 1938 <br />LP Gas HWM 3638 I 3259 3129 3009 2897 2794 2697 2607 2523 2444 2370 <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R.VALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />-3- <br />