<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTlol\l
<br />CHAPTER 5. BUILDING DESIGN BY COMPONENT PERFORMANCE APP"vA(;H
<br />ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS
<br />
<br />1
<br />
<br />All '" 1M I.\TE ZONES
<br />
<br />Z NE:
<br />BUILDING CLASSIFICATION S :
<br />BUILDING PERMIT NO.: ,;2.
<br />PERMmlNG OFFICE
<br />JURISDICTION NO.:
<br />
<br />
<br />~LS
<br />
<br />I BUILDING INFORMATION
<br />i WALLS ROC>F/CEILlNG FLOORS DOORS GLASS
<br /> TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br /> Concrete (CBS) .It ~'::UB Under attic .oS A/~'h' SlaIHlnllrade 0 7Q--rO Wood Single, wall (,I 402
<br /> Wood frame Single Assembly Raised Wood Metal Double, wall
<br /> Metal frame Other: Raised concrete Insulated .'2- e,4 Single, roof
<br /> Insulation R-value G Insulation R-value 19 Insulation R-value 0 I ~lher<;_ \,1 f.><t Double, roof
<br /> _ Lf). "
<br />
<br /> SYSTEMS INFORMATION
<br />AIR CONDITIONER HEATING SYSTEM , ). OT WATER
<br />TYPE EFFICIENCY -rn~ TYPE EFFICIENCY BTU/H TYPE
<br />Unitary & Heat Pump ~~.~ ~T. Central & Heat Pump -"I5HSPF G.~ .000 Electric
<br /><65,000 Blulh ~SEER - < 65.000 Btu 1 h Resistance IH
<br />,,-65,000 Btulh EER IPLV 2: 65.000 Btu/h _COP - Dedic31ed Heat Pump 0
<br /> - - - Water cooled _COP Gas
<br /> -
<br />Water Cooled - EER - IPLV - Evaporallvely cooled _COP Natural 0
<br /> -
<br />Evaporatlvely Cooled - EER - Electric resistance _COP LPG 0
<br /> -
<br />PTAC EER Gas/OlI (circle one) , . . Oil 0
<br />- -
<br />Chillers - COP - IPLV - < 225,000/300,000 Btu/h _ AFUE - HRU 0
<br />Other: 2: 225,000/300,000 Btu/h _Et - Olhe' -
<br /> If,4~S 1.44- 'J__ !5" -~
<br />UGHTlNG Total Lighting Wattage = Lighting Budget: DUCTS r. value: ~.'Z.
<br /> Total Conditioned Floor Area ., et,O Wattslsq,ft. (from Table 5-13)
<br /> ";..'"
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />Windows 502.4 Maximum of .37 elm per linear foot of operable sash crack. V
<br />Doors 502,4 Maximum of 1,25 cfm per square foot of door area. l/
<br />Joints/Cracks 502,4 To be caulked. gasketed. weatherstripped or otherwise sealed. --;7
<br />Reheat 503,3 Supply air restricted to set coldlhot deck temperature to meet load of worst case zone, Resistance reheai flruhibited, V
<br />Ventilation 503,4 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required, V
<br />HV AC Efficiency 503.4 Minimum efficiencies-Heating: Tables 5-4,5-5 & 5-6, Cooling: Tables 5-7A, 5-7B. 5-8 & 5-9, V
<br />Transport Energy 503.5 Minimum of 8,0. V
<br />Balancina 503,6 Provide means for balanclna HVAC air svstem & water distribution svstem, .........
<br />HV AC Controls 503,7 SeDarate readilv accessible manual or automatic thermostat for each svstem, V
<br />HV AC Ducts 503.8 Air ducts. fittings. mechanical equipment and plenum chambers shall be mechanically attached, sealed. "'.../
<br /> 503,9 Insulated and Installed in accordance with the criteria of sections 503.8. 503,9 and 503.10,
<br /> 503.10
<br />Piping Insulation 503.11 In accordance with Table 5-10, ....-
<br />Water Heaters 504.2 Automatic electric storage water heaters s 120 gallons and gas & oil-fired storage water heaters s 75.000 BtuIh shall
<br /> meet performance minimums in Table 5-11. Electric> 120 gallons: standby loss < .3O+ZlNr Gas> 75,000, Oil> ~
<br /> 105.000: E .78, Standby loss 1.30 + 114NT. Gas, Oil> 155.000: E,.78. standby loss 1,30 + 95Nr
<br />Swimming Pools 504.2 Spas & heated pools must have covers, Non-commercial pools must have pump timer, N.A
<br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 78%.
<br />Hot Water Pipe 504,4 Piping heat loss Is limited to 17.5 Btuth linear foot of pipe for recirculating systems (sge Table 5-12), ./
<br />Insulation
<br />Water Fixtures 504.5 Water flow restricted to maximum of 3 gpm at 80 pslg; toilets maximum 3,5 gallon flush, V
<br /> Public lavatory fixture maximum flow of .5 gpm or .5 gallon if has self-closing valve, ._-~---_.
<br />Lighting 505.1 Lighting power budgets are listed in Table 5-13. Minimum Ballast Efficacy Factors are listed in Table 5-'", v'
<br />
<br />Uo wall Allowable ... ~"., Uo wall Actual ... "t~ II complying under the p~1s1ons of S.502,2 enter the combined Uo values for the entire envelope
<br />Uo roof I ceiling Allowable . '" Uo roof 1 ceiling Actual . lit; In this section, ,
<br />Uo floor Allowable D Uo floor Actual 0 Uo envelope Allowable . -Z 0 Uo envelope ActUal . , ..
<br />OTTV wall Allowable ..", ?, OTTV wall Actual IT:
<br />OTTV roof I cellina Allowable &..II!I. OTTV roof 1 ceillna Actual ,-,..","
<br />
<br />Compliance with Chap18r 5was demonstrated by a Prescriptive Measures methodology: N t A ,
<br />D 508,0 (a) Detached commercial buildings D 508.0 (b) Skyboxes or sports stadium buildings
<br />less than 100 square feet. that are used only seasonally.
<br />
<br />I her,my certtfy that the
<br />with the Florida Energy
<br />PREPARED BY:
<br />I hereby certify that lhiII
<br />
<br />OWNER/AGENT:
<br />
<br />
<br />[~ 508.0(c) Traffic safety
<br />control towers
<br />
<br />CO\/8I"lId by !he calculation are In oompllance Review 01 plans end lpeCIflcatlons covered by this calculation indicates compliance with the
<br />3J/ I"" fI ~ Florida Energy Code. Before ~Ion is oompleted, this building will be inspected for
<br />DATE: .", compliance In accordance with n 553~S' , ~
<br />Energy Code'llr ( , Itl BUILDING OFFICIAl: ~, A..A.,..~ A .
<br />DATE: -;J (" DATE: 5" -