<br />Department of Community Affairs - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />FcmM 600A-93 Residential Component Prescriptive Method A CENTRAL 4 5 6
<br />
<br />\ .JNS
<br />CLIMATE D D D
<br />OFFICE: ZONE: 4 5 6
<br />PERMITNO.~ JURISDICTION NO,: ITII:IIJ
<br />
<br />Please Print CK
<br />
<br />
<br />PROJECT NAME:
<br />AND AODRESS:
<br />
<br />
<br />BUILDER:
<br />PERMITTING
<br />
<br />OWNER: l'L~ ..
<br />
<br />',.v "../
<br />
<br />1. New construction or addition
<br />2. Single family detached or Multifamily attached
<br />3. If Multifamily-No. of units covered by this submission
<br />4. If Multifamily, is this a worst case (yes / no)
<br />5. Conditioned floor area (sq, ft,)
<br />6. Predominant eave overhang (ft,)
<br />7. Porch overhang length (ft,)
<br />8. Glass area and type:
<br />a, Clear glass
<br />b, Tint, film or solar screen
<br />9. Floor type and insulation:
<br />a, Slab on grade (R-value + perimeter)
<br />b, Wood, raised (R-value + sq, ft.)
<br />c, Concrete, raised (R-value)
<br />10. Net Wall type area and insulation:
<br />a. Exterior: 1, Concrete (Insulation R-value)
<br />2, Wood frame (Insulation R-value)
<br />3, Steel (Insulation R-value)
<br />4, Log (Insulation R-value)
<br />
<br />b. Adjacent: 1, Concrete (Insulation R-value)
<br />2. Wood frame (Insulation R-value)
<br />3, Steel (Insulation R-value)
<br />4, Log (Insulation R-value)
<br />11. Ceiling type area and insulation:
<br />a, Under attic (Insulation R-value)
<br />b, Single assembly (Insulation R-value)
<br />12. Air distribution systems
<br />a. Ducts (Insulation + Location)
<br />b, Air Handler( Insulation + Location)
<br />13. Cooling system
<br />(Types: central-split, central-single pkg., room unit, PTAC" none)
<br />
<br />14. H,eating system:
<br />(Types: heat pump, elec, strip, nat. gas, L.P, gas, room or PTAC, none)
<br />15. Hot water system:
<br />(Types: elec" natural gas, solar, L.P, gas, none)
<br />16. Hot Water Credits:
<br />a, Heat Recovery (HR)
<br />b. Dedicated Heat Pump(DHP)
<br />17. Infiltration practice: 1, 2 or 3
<br />18. HV AC Credits (Type in Letter designation: CF-Ceiling Fan, CV-Cross vent,
<br />HF-Whole house fan, AS-Attic radiant barrier, MZ-Multizone)
<br />19. EPI (must not exceed 100 points)
<br />
<br />a, Total As-Built points
<br />b, Total Base points
<br />
<br />-1-
<br />
<br />
<br />1. ./ ./~v.J
<br />2. rj<vC/j-
<br />3. /
<br />4.
<br />5. I (P zS
<br />6. 1,.3~
<br />7. - S-'
<br /> Single Pane Double Pane
<br />8a. sq, ft, sq. ft.
<br />8b. sq. ft, 'LJ I sq. ft,
<br />9a. R= 0 , 19 L. I. ft.
<br />9b, R= , sq, ft,
<br />9c, R= , sq. ft,
<br />1 Oa-1 R= sq, ft.
<br />10a-2 R= , l 9 ,~ sq, ft,
<br />1 Oa-3 R= sq, ft,
<br />10a-4 R= sq. ft, --
<br />1 Ob-1 R= sq, ft,
<br />10b-2 R= I , 30ti' sq. ft.
<br />10b-3 R= sq, ft,
<br />1 Ob-4 R= sq, ft,
<br />11a, R= 2.'l- 114 2.5 sq, ft,
<br /> ---
<br />11b. R= sq, ft.
<br />12a. R= b , ~~COnd.lUnCond.)
<br /> ---
<br />12b, R= , __ (cond.luncond.) ------~---
<br /> I I
<br /> r' i
<br />13. Type: L. ~~ '1 ~A...~ ----
<br /> SEER/EER/COr: I\). .:.J 0 ---
<br />14. Type: J I{:.~.j Pu ""p --
<br /> HSPF/COP/AFUE: ? IS'
<br />15. Type: t-/ (- t of
<br /> EF: 'I --
<br />16a.
<br />16a.
<br />17. "'Z.-
<br />18. C~,tll, --
<br />119. 75: b I -
<br />19a. '-2 J'k, -----
<br />19b. 30LJ~
<br />
<br />Review of plans and specifications cov.red by this calculation indicates compliance with
<br />the Florida Energy Code. Betor onstruction IS completed, this buiJd.iell wIll be Inspected
<br />for compliance. in accordanc i Section "Ywa, F.S.
<br />
|