<br />ADDITIONAL TABLES <br />"6A-1SIfEATING CREDIT MULTIPLIERS HCM <br />_____~!)T~_M TYPL-_~_ <br />Attic Radiant Barrier <br />--~_._-------- <br />Multizone <br />Natural Gas <br /> <br />CLIMATE ZON~S, 4 5 6 <br /> <br />LP Gas <br /> <br />HCM <br />HCM <br />AFUE <br />HeM <br />HCM <br /> <br />HEATING CREDIT MULTIPLIERS (HCM) <br />,98 <br />.90 <br /> <br />.68-,72 <br />_61 <br />.-.-------------- <br />.77 <br /> <br />.73-.77 <br />.56 <br />~~,.~-------~- <br />.72 <br /> <br />.78-,82 <br />.53 <br />----.----- <br />.67 <br /> <br />- --- <br />.83-.87 <br />.50 <br />~--- <br />,63 <br /> <br />,88-.92 <br />.47 <br />----- <br />.60 <br /> <br />_ __ ,93_~1Jp_ <br />.44 <br />-----'._------ <br />,57 <br /> <br />6A.19 COOLING CREDIT MULTIPLIERS CCMl <br /> SYSTEM TYPE COOLING CREDIT MUL TIPUERS (CCM) <br />--- . .86' <br />Ceiling Fans -- .._---~.._._---------_.- ~-----_. _a_'___ -- <br />_9ross Ventilatio~__ .90' - 'Credit may be taken for only <br />_VVhoIElI:lOUSElJa,n_~_,__~______ --- .90' -- one of these system types concurrently, <br />Multizone -------.- --- ____~____:9_5~_________ <br />Attic Radiant Barrier .95 <br /> <br />6A-20 HOT WATER CREDIT MULTIPLIERS IHWCMI <br />SYSTEM TYPE <br /> <br />Dedicated Heat Pump <br /> <br />With <br />HWCM <br />~f <br />HWCM <br /> <br />HOT WATER CREDIT MULTIPLIERS lHWCML <br /> <br />U u.,= - H2~~49.'" fO"'- 25~991--. 3~~"-""lf - <br /> <br /> <br />A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM. SEE TABLE 6A,9 EF MEANS ENERGY" FACTOR <br /> <br />3.5 & Up <br />,25 <br /> <br />Heat Recovp;y Unit <br /> <br />6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606,1 COMPLY WITH All INFilTRATION PRESCRIPTIVES, <br />Windows 606.1 Maximum of 0,34 CFM per linear foot of operable sash crack (includes slidina alass doors). <br />Exterior & Adiacent Doors 606.1 Maximum of 0,5 CFM per sa, ft, of door area; solid core, wood oanel, insulated or alass doors only, <br />Exterior Joints & Cracks 606.1 To be caulked, aasketed, weatherstripped or otherwise sealed, <br />PRACTICE #2 606.2 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Too olate oenetrations sealed, Infiltration barrier installed, Sole plate/floor ioint caulked or sealed, <br />Exterior Walls & CeilinQs Penetrations, ioints and cracks on interior surface caulked, sealed or aasketed, <br />Ductwork Ductwork in unconditioned space must be sealed, <br />Fireplaces Eauipped with outside combustion air, doors, and flue dampers, <br />Exhaust Fans - n_ ________._ ___. Eauiooed with dampers, Combustion devices see 606,1 A2 --._- <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust to outside. <br /> Cookina appliances shall be dampered and use intermittent ianition, <br />PRACTICE #3 606,2 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilings_ _ Infiltration barrier installed, <br />Interior Walls Too oenetrations sealed or ioints & cracks on interior walls caulked, sealed or aasketed, <br />Recessed Liahts Sealed from conditioned & insulated from ventilated attic spaces, <br />Ductwork All ductwork located in conditioned space, <br /> <br />6A.22 OTHER PRESCRIPTIVE MEASURES Imust be met or exceeded bv all residences.l <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12, Switch or clearly marked circuit breaker (electric) <br /> or cutoff laas) must be provided, External or built-in heat tran renuired, <br />Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated), Non-commercial pools must have <br /> a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%, <br />Shower Heads 612,1 Water flow must be restricted to no more than 3 aallons oer minute at 80 PSIG, <br />HV AI:, Duct Construction 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />Insulation & Installation sealed, insulated, and installed in accordance with the criteria of Section 904.6, Duct in unconditioned <br /> space and air handlers located in attics must be insulated to a minimum of R-6, Air handlers shall not <br /> be installed in attics unless in mechanical closet. <br />HV AC Controls 607.1 Separate readilv accessible manual or automatic thermostat for each svstem, <br />Insulation 604.1,602,1 Ceilinas-Min. R-19, Common wall:~-Frame R-ll or CBS R-3 both sides, Common ceilina & floors R-11, <br /> <br />,6- <br />