<br />'. . . FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />FORM 500 A-93 CHAPTER 5 . BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH
<br />. , ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS
<br />Non.Resldentl.1 Buildings
<br />Re.ldentl.1 Buildings over 3 .torle. ALL CLIMATE ZONES
<br />PROJECT NAME: ZONE:
<br />ADDRESS: BUILDING CLASSIFICATIONlS):
<br />CITY. ZIP CODE: BUILDING PERMIT NO.:
<br />BUILDER: PERMITTING OFFICE:
<br />OWNER: JURISDICTION NO.:
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrete (CBS) .,~ J ("~ ~ Under attic .611 ""OCfO Slab-on1lrade 6 \Ot['() Wood JIo n"'t~ Single, wall ~,y t "t:;.JI;
<br />Wood frame Single Assembly Raised Wood Metal Double, wall
<br />Metal frame Other: Raised concrete Insulated Single, roof
<br />Insulation R-value Insulation R-value Insulation R-value Other Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br />AIR CONDITIONEF,i HEATING SYSTEM HOT WATER
<br />TYPE EFFICtEN~Y TONS TYPE EFFICIENCY BTU/H TYPE
<br />Unitary & Heat Pump 1L Central & Heat Pump ?i dfJO Electric
<br /><65,000 Btulh /6.&csEER ;)- < 65,000 Btu/h ~HSPF Resistance 0
<br />,,65,000 Btulh EER IPLV ~65,OOO Btu/h _COP - Dedicated Heat Pump 0
<br /> - - - Water cooied _COP Gas
<br /> -
<br />Water Cooled - EER - IPLV - Evaporatively cooled _COP 0
<br /> - Natural
<br />Evaporatively Cooled - EER - Electric resistance _COP LPG 0
<br /> -
<br />PTAC - EER - Gas/Oil (circle one) Oil 0
<br />Chillers - COP - IPLV - < 225,000/300,000 Btu/h _ AFUE - HRU 0
<br />Other: ~ 225,000/300,000 Btu/h Et Other:
<br />LIGHTING Total LiQhting Wattage ';?o ~C = I. in Lighting Budget: ::L. '\ DUCTS R-value:
<br /> Total Conditioned Floor Area / f,. L(!> Wattslsq,ft, (from Table 5-13)
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />Windows 502,4 Maximum of ,37 elm per linear foot of operable sash crack, X.
<br />Doors 502.4 Maximum of 1,25 elm per square foot of door area, '1-..
<br />Joints/Cracks 502,4 To be caulked. gasketed, weatherstripped or otherwise sealed, X
<br />Reheat 503,3 Supply air restricted to set cold/hot deck temperature to meet load of worst case zone, Resistance reheat prohibited, ..,...,
<br />Ventilation 503,4 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required, 1..
<br />HVAC Efficiency 503,4 Minimum efficiencies-Heating: Tables 5-4,5-5 & 5-6, Cooling: Tables 5-7A, 5-7B. 5-8 & 5-9, 'J..
<br />Transport Energy 503,5 Minimum of 8,0, 'y
<br />Balancing 503,6 Provide means for balancing HVAC air svstem & water distribution svstem, 'J
<br />HVAC Controls 503,7 Separate readilv accessible manual or automatic thermostat for each system, '1
<br />HV AC Ducts 503.8 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed,
<br /> 503,9 insulated and installed in accordance with the criteria of sections 503,8, 503,9 and 503,10. J
<br /> 503,10
<br />Piping Insulation 503,11 In accordance with Table 5-10. ."
<br />Water Heaters 504,2 Automatic electric storage water heaters s 120 gallons and gas & oil-tired storage water heaters s 75,000 BtuIh shall
<br /> meet performance minimums in Table 5-11. Electric> 120 gallons: standby loss < .3O+27Ny. Gas> 75,000, Oil> l:j,
<br /> 105,000: E .78. Standby loss 1,30 + 114NT' Gas, Oil> 155,000: E,.78, standby loss 1.30 + 951Vy.
<br />Swimming Pools 504,2 Spas & heated pools must have covers, Non-commercial pools must have pump timer, lJil
<br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 78%,
<br />Hot Water Pipe 504,4 Piping heat loss is limited to 17,5 Btu/h linear foot of pipe for recirculating systems (see Table 5-12), l
<br />Insulation
<br />Water Fixtures 504,5 Water flow restricted to maximum of 3 gpm at 80 psig; toilets maximum 3,5 gallon flush, "
<br /> Public lavatory fixture maximum flow of ,5 gpm or ,5 gallon if has self.closing valve,
<br />Lighting 505,1 Lighting power budgets are listed in Table 5-13, Minimum Ballast Efficacy Factors are listed in Table 5-14, 'I.
<br />
<br />Uo wall Allowable ,. ",) {) Uo wall Actual . -:.-" , If complying under the provisions of S, 502,2 enter the combined Uo values for the entire envelope
<br />Uo roof/ ceiling Allowable . to Uo rooll ceiling Actual . b ~ in this section,
<br />Uo floor Allowable Uo floor Actual Uo envelope Allowable Uo envelope Actual
<br />OTTV wall Allowable )D..... OTTV wall Actual I'ir U
<br />OTTV roof/ceiling Allowable OTTV rooll ceiling Actual
<br />
<br />Compliance with Chapter 5was demonstrated by a Prescriptive Measures methodology:
<br />D 508.0 (a) Detached commercial buildings D 50B.0 (b) Skyboxes or sports stadium buildings
<br />less than 100 square feet. that are used only seasonally,
<br />
<br />I hereby certify that t
<br />with the Florida Ene
<br />PREPARED BY:
<br />I hereby certify that his buildi i
<br />I
<br />OWNERlAGENT~
<br />
<br />
<br />D 508.0(c) Traffic safety
<br />control towers
<br />
<br />Review of plans and spec~ications covered by this calculation indicates compliance w~h the
<br />Florida Energy Code, Before construction is completed, this building will be inspected for
<br />compliance in accordance with Section 553,908, F,S,
<br />BUILDING OFFICIAL:
<br />
<br />DATE:
<br />
|