<br /> . , <br /> 'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />. . F,ORM 509 A.93 CHAPTER 5 . BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH <br /> Non-Residential Buildings ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS <br /> Residential Buildings over 3 stories ALL CLIMATE ZONES <br /> PROJECT NAME: ZONE: <br /> ADDRESS: BUILDING CLASSIFICATIONlS): <br /> CITY. ZIP CODE: BUILDING PERMIT NO.: <br /> BUILDER: PERMITTING OFFICE: <br /> OWNER: JURISDICTION NO.: <br /> <br /> BUILDING INFORMATION <br />WALLS ROOF/CEILING FLOORS DOORS GLASS <br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA <br />Concrete (CBS) ~151 J ("s( ~ Under attic .6L1 ~OqO Slab-oni)rade 6 ">o,['() Wood iJO i ) /Joe (. Single, wall I.. ..oil.... ,J. <br />" <br />Wood frame Single Assembly , Raised Wood Metal Double, wall , <br />Metal frame Other: Raised concrete Insulated Single, roof <br />Insulation R-value Insulation R-value Insulation R-value Other Double, roof <br /> <br /> SYSTEMS INFORMATION <br />AIR CONDITIONE8 HEATING SYSTEM HOT WATER <br />TYPE EFFICIENGY TONS TYPE EFFICIENCY BTU/H TYPE <br />Unitary & Heat Pump 1L- Central & Heat Pump ti5 4"0 Electric <br /><65,000 Btu/h ID$-SEER :) < 65,000 Btu/h ~HSPF Resistance 129- <br />,,65,000 Btu/h EER IPLY 2: 65,000 Btu 1 h _COP - Dedicated Heat Pump 0 <br /> - - - Water cooled _COP Gas <br /> - <br />Water Cooled - EER - IPLY - Evaporatively cooled _COP 0 <br /> - Natural <br />Evaporatively Cooled - EER - ElectriC resistance _COP LPG 0 <br /> - <br />PTAC - EER - Gas/Oil (circle one) Oil 0 <br />Chillers - COP - IPLY - < 225,000/300,000 Btu 1 h _AFUE - HRU 0 <br />Other: 2: 225,000/300,000 Btu/h Et Other: <br />LIGHTING Total Lighting Wattage :? 0 ~(~ = (. x ~ Lighting Budget: '2.,.- \ DUCTS R-value: <br /> Total Conditioned Floor Area i I~ I.( D Wattslsq,ft (from Table 5-13) <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Windows 502,4 Maximum of ,37 cfm per linear foot of operable sash crack, X <br />Doors 502.4 Maximum of 1,25 cfm per square foot of door area, ~ <br />Joints/Cracks 502.4 To be caulked, gasketed, weatherstripped or otherwise sealed, )( <br />Reheat 503,3 Supply air restricted to set cold/hot deck temperature to meet load of worst case zone, Resistance reheat prohibited, "1--- <br />Ventilation 503,4 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required, .;., <br />HV AC Efficiency 503,4 Minimum efficiencies-Heating: Tables 5-4, 5-5 & 5-6, Cooling: Tables 5-7A, 5-7B, 5-8 & 5-9, '" <br />Transport Energy 503,5 Minimum of 8,0, 'y <br />Balancing 503,6 Provide means for balancing HVAC air system & water distribution system, 'J <br />HV AC Controls 503,7 Separate readily accessible manual or automatic thermostat for each system, '1 <br />HV AC Ducts 503,8 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, <br /> 503,9 insulated and installed in accordance with the criteria of sections 503,8, 503,9 and 503,10, I <br /> 503,10 <br />Piping Insulation 503,11 In accordance with Table 5-10, 7 <br />Water Heaters 504,2 Automatic electric storage water heaters ~ 120 gallons and gas & oil-fired storage water heaters ~ 75,000 BtuIh shall <br /> meet performance minimums in Table 5-11. Electric> 120 gallons: standby loss < ,3O+27Nr Gas> 75,000, Oil> "j <br /> 105,000: E .78, Standby loss 1,30 + 114NT' Gas, Oil> 155,000: E, ,78, standby loss 1,30 + 95Nr <br />Swimming Pools 504,2 Spas & heated pools must have covers, Non-commercial pools must have pump timer. IJFl <br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 78%, <br />Hot Water Pipe 504,4 Piping heat loss is limited to 17,5 Btu/h linear foot of pipe for recirculating sys1ems (see Table 5-12), 7 <br />Insulation <br />Water Fixtures 504,5 Water flow restricted to maximum of 3 gpm at 80 psig; toilets maximum 3,5 gallon flush, '7' <br /> Public lavatory fixture maximum flow of ,5 gpm or ,5 gallon if has self-closing valve, <br />Lighting 505,1 Lighting power budgets are listed in Table 5-13, Minimum Ballast Efficacy Factors are listed in Table 5-14, 'I, <br />Uo wall Allowable f'~1'I Uo wall Actual . ....." . If complying under the provisions of S, 502,2 enter the combined Uo values for the entire envelope <br />Uo roof 1 ceiling Allowable . CO UO roof! ceiling Actual . 'II \..f in this section, <br />Uo floor Allowable Uo floor Actual Uo envelope Allowable Uo envelope Actual <br />OTTV wall Allowable ']>D,..... OTTV wall Actual ' cr ,-a <br />OTTV roof! ceiling Allowable OTTV roof / ceilinQ Actual <br /> <br />Compliance with Chapter Swas demonstrated by a Prescriptive Measures methodology: <br />D 508,0 (a) Detached commercial buildings D 508,0 (b) Skyboxes or sports stadium buildings <br />less than 100 square feet. that are used only seasonally, <br /> <br />D 508,O(c) Traffic safety <br />control towers <br /> <br />I hereby certify that t <br />with the Florida Ene <br />PREPARED BY: <br />1 hereby cenify th" <br /> <br />OWNER/AGENt, : <br />:'"""- <br /> <br /> <br />DATE: 7 - l~ 9!:> <br />orida Energy Codel j.' <br />DATE: ill "f ti::J, <br />( , <br /> <br />Review of plans and specifications covered by this calculation indicates compliance with the <br />Florida Energy Code, Before construction is completed, this building will be inspected for <br />compliance in accordance with Section 553,908, F,S, <br />BUILDING OFFICIAL: <br /> <br />DATE: <br />