<br />" , ' FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />FORM 500 A-93 CHAPTER 5 . BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH
<br />Non.Realdentlal Bulldlnga ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS
<br />Realdentlal Bulldlnga over 3 atorlea ALL CLIMATE ZONES
<br />PROJECT NAME: ZONE:
<br />ADDRESS: BUILDING CLASSIFICATION'S\:
<br />CITY. ZIP CODE: BUILDING PERMIT NO.:
<br />BUILDER: PERMITTING OFFICE:
<br />OWNER: JURISDICTION NO.:
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILlN G FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrete (CBS) .151 I ("~ ~ Under attic .6t1 ",oC(O SlalHlnilrade ~ .,>oc['() Wood JkJ 11'~' , Single, wall ..,~ t t1<'~
<br />Wood frame Single Assembly Raised Wood Metal Double, wall .
<br />Metal frame Other: Raised concrete Insulated Single, roof
<br />Insulation R-value Insulation R-value Insulation R-value Other Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br />AIR CONDITIONE13 HEATING SYSTEM HOT WATER
<br />TYPE EFFICfENGY TONS TYPE EFFICIENCY' BlUtH TYPE
<br />Unitary & Heat Pump 1L Central & Heat Pump ti'7 (J" 0 Electric
<br /><65,000 Btu/h ID~EER ~ < 65,000 Btu / h ..2.J!2 HSPF Resistance 0
<br />;?,65,OOO Btu/h EER IPlV 2: 65,000 Btu / h _COP - Dedicated Heat Pump 0
<br /> - - - Water cooled _COP Gas
<br /> -
<br />Water Cooled - EER - IPlV - Evaporatively cooled _COP Natural 0
<br /> -
<br />Evaporatively Cooled - EER - Electric resistance _COP LPG 0
<br /> -
<br />PTAC - EER - Gas/Oil (circle one) Oil 0
<br />Chillers - COP - IPlV - < 225,000/300,000 Btu/h _ AFUE - HRU 0
<br />Other: 2: 225,000/300,000 Btu/h Et Other:
<br />UGHTING Total Lighting Wattage ':?(!) ~O = I. 8' 5 Lighting Budget: :2.,.. '\ DUCTS R-value:
<br /> Total Conditioned Floor Area II" L(D Wattslsq.tt. (from Table 5-13)
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />Windows 502,4 Maximum of ,37 cfm per linear foot of operable sash crack, X
<br />Doors 502.4 Maximum of 1 ,25 cfm per square foot of door area, ..,.."
<br />Joi nts/Cracks 502.4 To be caulked, gasketed. weatherstripped or otherwise sealed, X.
<br />Reheat 503,3 Supply air restricted to set cold/hot deck temperature to meet load of worst case zone, Resistance reheat prohibited, "1-.
<br />Ventilation 503.4 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required, of...
<br />HV AC Efficiency 503.4 Minimum efficiencies-Heating: Tables 5-4, 5-5 & 5-6, Cooling: Tables 5-7A, 5-7B, 5-8 & 5-9. j.
<br />Transport Energy 503,5 Minimum of 8,0, "I
<br />Balancing 503,6 Provide means for balancing HV AC air system & water distribution system, 'j
<br />HV AC Controls 503,7 Separate readily accessible manual or automatic thermostat for each system, '1
<br />HV AC Ducts 503,8 Air ducts, fittings. mechanical equipment and plenum chambers shall be mechanically attached, sealed.
<br /> 503,9 insulated and installed in accordance with the criteria of sections 503,8, 503,9 and 503,10, 7
<br /> 503,10
<br />Piping Insulation 503,11 In accordance with Table 5-10, "
<br />Water Heaters 504,2 Automatic electric storage water heaters S 120 gallons and gas & oil-fired storage water heaters S 75,000 BtUIh shall
<br /> meet performanc18 minimums in Table 5-11, Electric> 120 gallons: standby loss < .3IJ+27Nr Gas> 75.000, Oil> "j.
<br /> 105,000: E, .78. Standby loss 1.3IJ + 114NT. Gas. Oil> 155.000: E, .78, standby loss 1.30 + 95Nr
<br />Swimming Pools 504,2 Spas & heated pools must have covers, Non-commercial pools must have pump timer, /.Iv?
<br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 78%,
<br />Hot Water Pipe 504.4 Piping heat loss is limited to 17,5 Btu/h linear foot of pipe for recirculating systems (see Table 5-12), I
<br />Insulation
<br />Water Fixtures 504,5 Water flow restricted to maximum of 3 gpm at 80 psig; toilets maximum 3,5 gallon flush, "
<br /> Public lavatory fixture maximum flow of ,5 gpm or ,5 gallon if has self-closing valve,
<br />Lighting 505,1 Lighting power budgets are listed in Table 5-13, Minimum Ballast Efficacy Factors are listed in Table 5-14, 'I.
<br />
<br />Uo wall Allowable f'-~ 0 Uo wall Actual ' "'J.-" I If complying under the provisions of S, 502,2 enter the combined Uo values for the entire envelope
<br />Uo roof / ceiling Allowable .cv Uo roof / ceiling Actual . 11 \.f in this section,
<br />Uo floor Allowable Uo floor Actual Uo envelope Allowable Uo envelope Actual
<br />OTlv wall Allowable '1:.1) r ..... OTTV wall Actual fCir U
<br />OTTV roof / ceiling Allowable - OTlv roof! ceiling Actual
<br />
<br />Compliance with Chapter 5was demonstrated by a Prescriptive Measures methodology:
<br />D 50B,O (a) Detached commercial buildings D 508.0 (b) Skyboxes or sports stadium buildings
<br />less than 100 square feet. that are used only seasonally,
<br />
<br />I hereby certify that t
<br />with the Florida Ene
<br />PREPARED BY:
<br />I hereby certify !P8t
<br />/
<br />OWNER/AGENT
<br />
<br />D 508,O(c) Traffic safety
<br />control towers
<br />
<br />
<br />DATE: 7 - l'~ 9'.!7
<br />orida Energy Code, ).'
<br />DATE: '1,_cr ':>
<br />
<br />Review of plans and specifications covered by this calculation indicates compliance with the
<br />Florida Energy Code, Before construction is completed, this building will be inspected for
<br />compliance in accordance with Section 553,908, F,S,
<br />BUILDING OFFICIAL:
<br />
<br />DATE:
<br />
|