Laserfiche WebLink
<br />. I;)epartment of Community Affairs - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FO~M 600A-93 Residential Component Prescriptive Method A CENTRAL 4 5 6 <br />PROJECT NAME: BUILDER: <br />AND AbDRESS: PERMITTING CLIMATE 405060 <br /> OFFICE: ZONE: <br />OWNER: PERMIT NO.CIILLD:Il JURISDICTION NO,: c::L[IIIJ <br /> <br />1. New construction or addition <br />2. Single family detached or Multifamily attached <br />3. If Multifamily-No. of units covered by this submission <br />4. If Multifamily, is this a worst case (yes / no) <br />5. Conditioned floor area (sq, ft.) <br />6. Predominant eave overhang (ft,) <br />7. Porch overhang length (ft,) <br />8. Glass area and type: <br />a, Clear glass <br />b, Tint, film or solar screen . <br />9. Floor type and insulation: <br />a, Slab on grade (R-value + perimeter) <br />b, Wood, raised (R-value + sq, ft,) <br />c, Concrete, raised (R-value) <br />10. Net Wall type area and insulation: <br />a. Exterior: 1, Concrete (Insulation R-value) <br />2, Wood frame (Insulation R-value) <br />3. Steel (Insulation R-value) <br />4, Log (Insulation R-value) <br /> <br />b. Adjacent: 1, Concrete (Insulation R-value) <br />2, Wood frame (Insulation R-value) <br />3. Steel (Insulation R-value) <br />4, Log (Insulation R-value) <br />11. Ceiling type area and insulation: <br />a, Under attic (Insulation R-value) <br />b. Single assembly (Insulation R-value) <br />12. Air distribution systems <br />a. Ducts (Insulation + Location) <br />b, Air Handler( Insulation + Location) <br />13. Cooling system <br />(Types: central-split, central-single pkg" room unit, PTAC" none) <br /> <br />14. Heating system: <br />(Types: heat pump, elec, strip, nat. gas, L.P, gas, room or PTAC, none) <br />15. Hot water system: <br />(Types: elec" natural gas, solar, L.P, gas, none) <br />16. Hot Water Credits: <br />a, Heat Recovery (HR) <br />b. Dedicated Heat Pump(DHP) <br />17. Infiltration practice: 1, 2 or 3 <br />18. HV AC Credits (Type in Letter designation: CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RS-Attic radiant barrier, MZ-Multizone) <br />19. EPI (must not exceed 100 points) <br /> <br />a, Total As-Built points <br />b. To se points <br /> <br /> <br />DATE: fl -)- b1J <br />nergy Code, <br /> <br />OWNER AGENT: <br /> <br />DATE: <br /> <br />-1- <br /> <br />Please Print <br /> <br />CK <br /> <br />1. {/ l-vU <br />2. mull t r ~h1-/ f <br />3. '-- <br />4. V,.5 <br />5. /,s-f' <br />6. /, ~ <br />7. ~ <br /> Single Pane Double Pane <br />8a, sq. ft. sq, ft, <br />l8H. sq, ft, sq. ft, <br />9a. R= 0 , /~'1 I. ft, <br />9b, R= , sq. ft. <br />9c, R= , sq, ft, <br />10a-1 R= 5 r 'P \.{ sq. ft, <br />10a-2 R= sq, ft, <br />1 Oa-3 R= sq. ft, <br />10a-4 R= sq, ft. <br />1 Ob-1 R= -4- ~ 5' v sq, ft, <br />10b-2 R= sq, ft. <br />10b-3 R= sq, ft, <br />10b-4 R= sq, ft. <br />11a. R= 70 t '-'~. ft. <br />11b. R= sq. ft. <br />12a. R= ~ ,~~ (cond.luncond,) <br />12b, R= , __ (cond.luncond,) <br />13. Type: C e ~1 vcl ( <br /> ~ERlCOP: Ie \. 01) <br />14. Type:H e vr /J If W'\/~ I <br /> HSPF/COP/AFUE: /vo- <br />15. Type: IE ( e-t- <br /> EF: . 9 / <br />16a. <br />16a. <br />17. ::J- <br />18. <br />119. <;>D\ I I <br />19a. / / "(7 <br />19b. 2'{ If 77 <br /> <br />Review of plans and specificetions covered by this calculation Indicates compliance with <br />the Florida Energy Code, Belore construction is completed, this building wm be inspected <br />lor compliance In accordance with Section 553,908. F.S. <br /> <br />BUILDING OFFICIAL: <br /> <br />DATE: <br />