Laserfiche WebLink
<br /> <br />. <br />. <br />. <br />I <br />I <br />I <br />I <br />II <br />I <br /> <br />Energy points shall be calculated for an As-Built house and a Baseline house using <br />actual house configuration and component net areas. Cooling Points, Heating Points and <br />Water Heating Points shall be calculated separately and then summed. The total points <br />for the As.Bullt house shall not exceed the total points for the Baseline house. For <br />a complete description of how to complete Form 600A-93, see the Residential Instruction <br />Manual, <br /> <br />600.2.A.1 General <br /> <br />600.2.A.1.1 Multipliers. Multipliers are provided on Form 600A-93 for commonly installed <br />technologies for each building component. Multipliers for some less commonly installed <br />technologies are provided in Appendix C to this document and are referenced by the <br />appropriate Code section. <br /> <br />Interpolations of multipliers are allowed by the procedure described in section 1.3 of <br />Appendix C where rated efficiencies of installed components fall within a range. <br />Extrapolations of multipliers above the highest value given or below the lowest values <br />given shall not be permitted. Multipliers are interpolated automatically in the FLA/RES-93 <br />computer program. <br /> <br />600.2.A.1.2 Insulation R-Values. R-values used to determine the appropriate multiplier <br />for the insulation level installed shall be the R-value of the added insulation only. <br />Appendix C, section 1,2 contains general rules for insulation which shall be followed. <br /> <br />600.2.A. 1.3 Areas, Areas used in the calculation shall be the actual net areas for each <br />component determined from the plans and specifications of the building to be <br />constructed, <br /> <br />600.2.A.2 Residences Not Heated or Not Cooled. Residences which are heated or <br />cooled, but not both, shall complete both summer and winter calculations, The Baseline <br />system multiplier divided by 1.10 shall be used for the heating or cooling system not <br />installed. The duct multiplier for the duct system to be installed shall be used for both <br />calculations. - <br /> <br />If an addition or part of an addition is claimed to be exempt from the Code because it will <br />be neither heated nor cooled, the exempt area shall be fully separated from the <br />conditioned area by walls or doors, <br /> <br />600.2.A.3 Additions <br /> <br />600.2.A.3.1 Additions Complying Alone, Additions to existing buildings shall follow the <br />same Method A calculation procedure as new construction with the following <br />qualifications, <br />1, Calculations shall be conducted using only the components of the addition itself, <br />including those pre-existing components which separate the addition from <br />unconditioned spaces, <br />2. Heating and Cooling System Multipliers shall be equal to the Baseline System <br />Multiplier divided by 1,10 unless new equipment is installed to replace existing <br />equip'ment or to service the addition specifically, Addition of new equipment may <br />qualify for multizone credit (see section 607,2.A.3,2) if all other criteria are met. The <br />multiplier for the new ductwork to supply the addition shall be used in the calculation. <br />~., '.1..", ..'.,.., '~..~,at.tr2S.tl,. "'I."t,..,~m,.",pg",!y.lu,','" 'nt.. ,..'., ,.,.'~",.,~!,o,.,hn~u,",I1,.,<.'e.",.s, s..asuPPlemental water heater <br />ISI,.ptfId,ln~Xl!L ~\ftte, ".~" ", ,',. ~tCr:t:rJ'afttmative';Mlterheater(gas, <br />"':~}!_~eh$Qtpump) IS '"staRed to galh credit. <br /> <br />6-3 <br />