<br />** INFILTRATIO~ REDUCTION PRACTICE COMPLIANCE CHECKLIST **
<br />
<br />===========~===================================~=========~=~===================
<br />
<br />SECTION
<br />
<br />REQUIREMENTS FOR EACH PRACTICE
<br />
<br />CHECK
<br />
<br />=~======================= =======================================================
<br />
<br />PRACTICE #1
<br />
<br />Windows
<br />
<br />Exte,io, &
<br />Adjacent Doo,s
<br />
<br />606.1
<br />
<br />606 1
<br />
<br />606.1
<br />
<br />COMPLY WITH ALL INFILTRATION PRESCRIPTIVES.
<br />
<br />Maximum of 0.34 CFM per linear toot of ope,able sash
<br />c,ack (includes sliding glass doors).
<br />
<br />Maximum of 0.5 CFM per sq. ft. of do 0, a,ea: solid
<br />co,e, wood panel,insulated or glass doo,s only.
<br />
<br />Exte,io, Joints
<br />& C,acks
<br />
<br />------------------------------------------------------ -.---.---------------------
<br />
<br />606.1
<br />
<br />To be caulked, gasketed, weather-st,"ipped 0, othe,-
<br />wise sealed.
<br />
<br />PRACTICE #2
<br />
<br />-------------------------------------------------------------------------------
<br />
<br />COMPLY WITH PRACTICE #1 AND THE FOLLOWING:
<br />
<br />606.1
<br />
<br />-------------------------------------------------------------------------------
<br />
<br />Exte,io, Walls
<br />& Floors
<br />
<br />606.1
<br />
<br />Top plate penet,ations sealed. Infiltration barrier
<br />installed. Sole plate/floor joint caulked or sealed.
<br />
<br />-------------------------------------------------------------------------------
<br />
<br />Exterior Walls
<br />& Ceilings
<br />
<br />606.1
<br />
<br />Penetrations, joints and cracks on interior surface
<br />caulked, sealed or gasketed,
<br />
<br />DuctWork
<br />
<br />--------------------------------------------------------------------------------
<br />
<br />Ductwork in unconditioned space must be sealed.
<br />
<br />606.1
<br />
<br />---------------------------------------------------------.----------------
<br />
<br />Fireplaces
<br />
<br />606.1
<br />
<br />Equipped with outside combustion air, doors and flue
<br />dampers.
<br />
<br />Exhaust Fans
<br />
<br />---------------------________________w___________________________________________
<br />
<br />606.1
<br />
<br />Equipped with dampers. Combustion devices see
<br />606.1.A.2.
<br />
<br />-------------------------------------------------------------------------------.-
<br />
<br />Combustion
<br />Appliances
<br />
<br />606.1
<br />
<br />Be in unconditioned space (except direct vent), d,aw
<br />air from unconditioned space, exhaust to outside.
<br />Cooking appliances shall be dampered and use
<br />intermittent ignition.
<br />
<br />Water Heaters
<br />
<br />** OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) **
<br />
<br />~-.__._._--_.,--_.__._--~--_._----_._-_._---_..,----------..-
<br />
<br />--.----------------------.- .--------------------.----------
<br />
<br />612~1
<br />
<br />Comply with efficiency requirements in Table 6-12.
<br />Switch or clearly marked circuit breaker (electric)
<br />or cutoff (gas) must be provided. External or built-
<br />in heat trap required.
<br />
<br />Swimming Pools
<br />& Spas
<br />
<br />--------------------------------------------------------------------------------
<br />
<br />612.1
<br />
<br />Spas and heated pools must have covers (except solar
<br />heated). Non-commercial pools must have a pump timer.
<br />Gas spa & pool heaters must have a minimum thermal
<br />efficiency of 78 percent.
<br />
<br />Showe)- Heads
<br />
<br />---------------------------------------------------------------------------------
<br />
<br />Water flow must be restricted to no more than 3 gal-
<br />lons per minute at 80 PSIG.
<br />
<br />612.1
<br />
<br />-------------------------------------------------------------------------------
<br />
<br />HVAC Duct
<br />Construction
<br />Insulation &
<br />Installation
<br />
<br />610.1
<br />
<br />All ducts, fittings, mechanical equipment and plenum
<br />chambers shall be mechanically attached, sealed, ins
<br />ulated and installed in accordance with the criteria
<br />of Section 610.1.ABC.2 & 610.1.ABC.3. Duct in attics
<br />must be insulated to a minimum of R-6. Air handlers
<br />shall not be installed in attics unless in mechanical
<br />closet,.
<br />
<br />._-----_._---------------------~------------------_._---
<br />
<br />HVAC Cant ',ols
<br />
<br />607,1
<br />
<br />-~ -- -- '.- ._-~. ..-. ,- - - ._, - - - - - - - -- ~.. --- -~' ---,' - '~~ '"-' v..... ~ ~ _ __ __ ~ _ _ ,~_ _~ __ _. ~~. _.__ '._ ,_~ _ _ ~ __ v_.._.~
<br />
<br />Separate readily accessible manual or automatic
<br />the,mostat for each system.
<br />
<br />Insulation
<br />
<br />604.1
<br />602.1
<br />
<br />Ceilings minimum R 19. Common Walls - Frame R-11 or
<br />CBS R-3 both sides. Common ceiling & floors R-11
<br />
<br />~,,- - ~ - -- ... '~_ _,~ 'c.w ~_ __ '_ _~ __ ~ _ _....... '__. .._ _ _... ,._
<br />
|