<br />COMPONE'NTS <br /> <br />** INFILTRATIO~ REDUCTION PRACTICE COMPLIANCE CHECKLIST ** <br /> <br />===========~===================================~=========~=~=================== <br /> <br />SECTION <br /> <br />REQUIREMENTS FOR EACH PRACTICE <br /> <br />CHECK <br /> <br />=~======================= ======================================================= <br /> <br />PRACTICE #1 <br /> <br />Windows <br /> <br />Exte,io, & <br />Adjacent Doo,s <br /> <br />606.1 <br /> <br />606 1 <br /> <br />606.1 <br /> <br />COMPLY WITH ALL INFILTRATION PRESCRIPTIVES. <br /> <br />Maximum of 0.34 CFM per linear toot of ope,able sash <br />c,ack (includes sliding glass doors). <br /> <br />Maximum of 0.5 CFM per sq. ft. of do 0, a,ea: solid <br />co,e, wood panel,insulated or glass doo,s only. <br /> <br />Exte,io, Joints <br />& C,acks <br /> <br />------------------------------------------------------ -.---.--------------------- <br /> <br />606.1 <br /> <br />To be caulked, gasketed, weather-st,"ipped 0, othe,- <br />wise sealed. <br /> <br />PRACTICE #2 <br /> <br />------------------------------------------------------------------------------- <br /> <br />COMPLY WITH PRACTICE #1 AND THE FOLLOWING: <br /> <br />606.1 <br /> <br />------------------------------------------------------------------------------- <br /> <br />Exte,io, Walls <br />& Floors <br /> <br />606.1 <br /> <br />Top plate penet,ations sealed. Infiltration barrier <br />installed. Sole plate/floor joint caulked or sealed. <br /> <br />------------------------------------------------------------------------------- <br /> <br />Exterior Walls <br />& Ceilings <br /> <br />606.1 <br /> <br />Penetrations, joints and cracks on interior surface <br />caulked, sealed or gasketed, <br /> <br />DuctWork <br /> <br />-------------------------------------------------------------------------------- <br /> <br />Ductwork in unconditioned space must be sealed. <br /> <br />606.1 <br /> <br />---------------------------------------------------------.---------------- <br /> <br />Fireplaces <br /> <br />606.1 <br /> <br />Equipped with outside combustion air, doors and flue <br />dampers. <br /> <br />Exhaust Fans <br /> <br />---------------------________________w___________________________________________ <br /> <br />606.1 <br /> <br />Equipped with dampers. Combustion devices see <br />606.1.A.2. <br /> <br />-------------------------------------------------------------------------------.- <br /> <br />Combustion <br />Appliances <br /> <br />606.1 <br /> <br />Be in unconditioned space (except direct vent), d,aw <br />air from unconditioned space, exhaust to outside. <br />Cooking appliances shall be dampered and use <br />intermittent ignition. <br /> <br />Water Heaters <br /> <br />** OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) ** <br /> <br />~-.__._._--_.,--_.__._--~--_._----_._-_._---_..,----------..- <br /> <br />--.----------------------.- .--------------------.---------- <br /> <br />612~1 <br /> <br />Comply with efficiency requirements in Table 6-12. <br />Switch or clearly marked circuit breaker (electric) <br />or cutoff (gas) must be provided. External or built- <br />in heat trap required. <br /> <br />Swimming Pools <br />& Spas <br /> <br />-------------------------------------------------------------------------------- <br /> <br />612.1 <br /> <br />Spas and heated pools must have covers (except solar <br />heated). Non-commercial pools must have a pump timer. <br />Gas spa & pool heaters must have a minimum thermal <br />efficiency of 78 percent. <br /> <br />Showe)- Heads <br /> <br />--------------------------------------------------------------------------------- <br /> <br />Water flow must be restricted to no more than 3 gal- <br />lons per minute at 80 PSIG. <br /> <br />612.1 <br /> <br />------------------------------------------------------------------------------- <br /> <br />HVAC Duct <br />Construction <br />Insulation & <br />Installation <br /> <br />610.1 <br /> <br />All ducts, fittings, mechanical equipment and plenum <br />chambers shall be mechanically attached, sealed, ins <br />ulated and installed in accordance with the criteria <br />of Section 610.1.ABC.2 & 610.1.ABC.3. Duct in attics <br />must be insulated to a minimum of R-6. Air handlers <br />shall not be installed in attics unless in mechanical <br />closet,. <br /> <br />._-----_._---------------------~------------------_._--- <br /> <br />HVAC Cant ',ols <br /> <br />607,1 <br /> <br />-~ -- -- '.- ._-~. ..-. ,- - - ._, - - - - - - - -- ~.. --- -~' ---,' - '~~ '"-' v..... ~ ~ _ __ __ ~ _ _ ,~_ _~ __ _. ~~. _.__ '._ ,_~ _ _ ~ __ v_.._.~ <br /> <br />Separate readily accessible manual or automatic <br />the,mostat for each system. <br /> <br />Insulation <br /> <br />604.1 <br />602.1 <br /> <br />Ceilings minimum R 19. Common Walls - Frame R-11 or <br />CBS R-3 both sides. Common ceiling & floors R-11 <br /> <br />~,,- - ~ - -- ... '~_ _,~ 'c.w ~_ __ '_ _~ __ ~ _ _....... '__. .._ _ _... ,._ <br />