Laserfiche WebLink
<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />Residential Whole Building Performance Method A <br />SILVER OAKS :BUILDER: EHRMAN SYSTEMS ENT, Inc, <br />101~~ A,)e1t't1+tM<.E. ~1t.. : PERt'l\ I TT I NG : CL HilA TE <br />ZEPH'{RHI LLS FL : OFF I CE: ZEPHYRHI L:J-S : ZONE: 4:':-: 5: _: 6: <br />!'I\/!'I\ DONALD PONOZZO :PER!vlIT No,...?R3..3.t5 :.JURISDICTION NO,t,//t60 <br />CK <br /> <br />FOR~I!' 600A-93 <br />PRO.JECT NA!'I\E: <br />AND ADDRESS: <br /> <br />OWNER: <br /> <br />1, New construction or addition <br />2, Single familY detached or MultifamilY attached <br />~, If Multifamily-No, of units <br />4. If MultifamilY, is this a worst case (yes/no) <br />5, Conditioned floor area (sq.ft,) <br />6. Predominant eave overhang (ft.) <br />7, P'::>l-.=h ':lverhang length (ft,) <br />8. Glass area and type: <br />a. Clear Gl.3ss <br />b, Tint, film or solar screen <br />9, Floor type and insulation: <br />a, Slab on grade (R-value, perimeter) <br />10.Net Wall type area and insulation: <br />a, Exterior: 1, Concrete (Insulation R-value) <br />a, Exterior: 2, Wood frame (Insulation R-value) <br />b. Adjacent: 2. Wood frame (Insulation R-value) <br />11,Ceiling type are.3 and insulation: <br />a, Under attic (Insulation R-value) <br />12,Air distribution systems <br />a, Ducts (Insulation + Location) <br />13,Cooling system <br /> <br />l4,Heating System: <br /> <br />15.Hot water sYstem: <br /> <br />l6.Hot Water Credits: (HR-Heat RecoverY, <br />DHP-Dedicated Heat Pump) <br />17.Infiltration practice: 1, 2 or 3 <br />l8,HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />19.EPI (must not e;<ceed 100 points) <br />a, Total As-Built points <br />b. Total Base points <br /> <br />I HerebY certifY that the plans and <br />specifications covered by this calcu- <br />lation are in compliance with the <br />Florida Ene.2:.g~/ C e, ~ <br /> <br />PREPAR~p BY: __ __ __~ __ <br />OATE:~_JiL__~9.~___________ ~___ <br /> <br />SN:,55l2 <br /> <br />CENTPAL <br /> <br />New Construction <br />2. Single-F'.3milY <br />o <br /> <br />1 , <br /> <br />..... <br />.j 11; <br /> <br />4 . <br />5, 2350.00 <br />6, 1 .00 <br />7. 9,00 <br />Single Pane <br />8.3.:381.7sqft <br />8b, O,Osq1:t <br /> <br />Double Pane <br />O,OOsqft <br />O.OOsqft <br /> <br />9.3.R= 0,00 <br /> <br />238.00 ft <br /> <br />10a-l R= 4,60, <br />10a-2 R=ll.OO, <br />10b-2 R=11.00, <br /> <br />1240.00sqft____ <br />48,OOsqft____ <br />221 ,00 s q f t ____ <br /> <br />lla,R=26.00 , 2765.00sqft____ <br /> <br />12a. R= 6.00 uncond <br />13. Type: Central A/C <br />SEEF<:: 10.40 <br />14, Type: Heat Pump <br />HSPF: 7,50 <br />15. Type: Electric <br />EF: 0.89 <br /> <br />16, <br /> <br />1 7 , <br />18, <br /> <br />..... <br />t:.. <br /> <br />19. <br />19.3, <br />19b. <br /> <br />85,19 <br />35591 ,22 <br />41778,39 <br /> <br />Review of the plans and specifications <br />covered bY this calculation indicates <br />compliance with the Florida Energy <br />Code, Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />55:3.908 F,S, <br /> <br />I hereby certifY that this building is <br />in compliance with the <br />Code, ~ <br /> <br />OWNER/AG~N~:_{~~~' <br />DATE:__JJ~_1iL_+_Lq <br /> <br /> <br />~~~~~~~}}.~~7-~~Ii~~~~~~- <br />