<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />Residential Component Prescriptive Method A <br />:BUILDER: <br />:PERMITTING <br />:OFFICE: <br />:PERMIT NO. <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected fOl <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br />FORi"1 600()-93 <br />PROJECT NAt1E: <br />()ND ADDRESS; <br /> <br />mmER- <br /> <br />1. New construction or addition <br />? Sinolc:') family detached or Multifamily at.tached'-" <br />3. If Multifamily-No. of units <br />4. If Mult.ifamily, is this a worst case (yes/no) <br />5. Conditioned floor area (sq.ft.) <br />E}. P':;,3dominant eave ovel"hang (ft.) <br />7. Porch overhang length (ft.) <br />8. Glass area and type: <br />a. Clear Glass <br />b. Tint, film or solar screen <br />9. Floor type and insulation: <br />a. Slab on grade (R--'../alue, per imet.er <br />10.Net Wall type area and insulation: <br />d. Exterior: 1. Concret.e (Insulat.ion R-value) <br />a. Adjacent.: 2. Wood frame (Insulation R-value) <br />11.Ceiling type area and insulat.ion: <br />a. under att.ic (Insulat.ion R-value) <br />12.Air distribution systems <br />d. Duct~: (In:3ulation + Locat.ion) <br />13.Cooling syst.em <br /> <br />14,Heating System: <br /> <br />l:'.Hot water <br /> <br />s/stem- <br /> <br />16.Hot Water Credits: (HR-Heat. Recovery, <br />DHP-Dedicat.ed Heat Pump) <br />17,Infiltrat.ion p'ractice: 1,2 or 3 <br />18.HVAC Credit.s (CF-Ceiling Fan. CV-Cross vent., <br />HF-Whole house fan, RB-Attic radiant <br />barrier. MZ-Multizone) <br />19.EPI (must not exceed 100 point.s) <br />a. Total As_Built point.s <br />b. Tot.al Base point.s <br /> <br />I Herebl certify that. t.he plans and <br />specificat.ions covered by t.his calcu- <br />lat.ion are in compliance with t.he <br />Florida Ener9Y C <br /> <br />PF:;EPARED BY" <br />DATE. <br /> <br /> <br />e. Q~______ <br />l--z.. ~ r-t:\ ~ <br /> <br />I herebl certify that t.his building is <br />in compliance wiUI t.he Florida Erl,sr:JY <br />Code. <br /> <br />OWNER/AGENT: <br />DATE <br /> <br />':;t'-1: 6024 <br /> <br />CENTRAL <br /> <br />:CLIMATE <br />: Z 0 N E: 4: _.: 5:: 6: _. : <br />:JURISDICTION NO. <br /> <br />CK <br /> <br />1. New Const.ruct.ion <br />Single-Family <br />o <br /> <br />3. <br /> <br />4 . <br /> <br />5.. 1:-,74..00 <br />1 . '50 <br /> <br />6. <br /> <br />7.00 <br />Single Pane <br />8a.624.0sqft <br />8b, O.Osqft. <br /> <br />7. <br /> <br />Double Pane <br />O.OOsqft <br />O.OOsqft. <br /> <br />9a .R'" 0.00 . <br /> <br />195.00 ft. <br /> <br />10a-l R= 5.00. 1574.00sqft. <br />10a-2 R=11.00, 213.00sqft <br /> <br />11a.R=30.00 . 1646.00sqft..__ <br /> <br />12a. R= 6.00 uncond <br />13. Type: Central A/C <br />SEER: 10.00 <br />14. Type: Heat. Pump <br />HSPF 7.10 <br />15. T/pe: Electric <br />EF 0.94 <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br /> <br />19. <br />19a. <br />19b. <br /> <br />92.70 <br />29867.07 <br />32218.16 <br /> <br />BUILDING OFFICIAL: <br />DATE: <br />