Laserfiche WebLink
<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 600A-93 Residential Component Prescriptive Method A CENTRAL <br />PROJECT NAME: SINGLE FAMILY RESIDE:BUILDER: GENERAL HOME DEVELOPMENT CORP. <br />AND ADDRESS: ~-"tJ3-IY.zi -<1:1- : PERMITT~NG : CLIMATE <br />ZEPHYRHILLS, FL 335:0FFICE: :ZONE: 4:~ 5:_: 6:_: <br />OWNER: M/M PECK :PERMIT O. .fYf L3 :JURISDICTION ~~i(;OD CK <br /> <br />1. New construction or addition 1. New Construction <br />2. Single family detached or Multifamily attached 2. Single-Family <br />3. If Multifamily-No. of units 3. 0 <br />4. If Multifamily, is this a worst case (yes/no) 4. <br />5. Conditioned floor area (sq.ft.) 5. 1469.00 <br />6. Predominant eave overhang (ft.) 6. 1.66 <br />7. Porch overhang length (ft.) 7. 0.00 <br />8. Glass area and type: Single Pane <br />a. Clear Glass 8a.166.7sqft <br />b. Tint, film or solar screen 8b. O.Osqft <br />9. Floor type and insulation: <br />a. Slab on grade (R-value, perimeter) <br />10.Net Wall type area and insulation: <br />a. Exterior: 1. Concrete (Insulation R-value) 10a-l R= 9.60, 927.40sqft~ <br />a. Adjacent: 2. Wood frame (Insulation R-value) 10a-2 R=11.00, 127.70sqft____ <br />11.Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />a. Under attic (Insulation R-value) <br />12.Air distribution systems <br />a. Ducts (Insulation + Location) <br />13.Cooling system <br /> <br />SN: 6096 <br /> <br />Double Pane <br />O.OOsqft <br />O.OOsqft <br /> <br />9a.R= 0.00 , 160.50 ft <br /> <br />lla.R=22.00, 48.00sqft____ <br />lla.R=30.00 , 1489.00sqft____ <br /> <br />14.Heating System: <br /> <br />12a. R= 6.00 , uncond <br />13. Type: Central A/C <br />SEER: 10.00 <br />14. Type: Heat Pump <br />HSPF: 7.00 <br />15. Type: Electric <br />EF: 0.90 <br /> <br />15.Hot water system: <br /> <br />16.Hot Water Credits: (HR-Heat Recovery, <br />DHP-Dedicated Heat Pump) <br />17.Infiltration practice: 1, 2 or 3 <br />18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />19.EPI (must not exceed 100 points) <br />a. Total As_Built points <br />b. Total Base points <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br /> <br />19. <br />19a. <br />19b. <br /> <br />82.88 <br />25061.79 <br />30238.96 <br /> <br />------------------------------------------------------------------------------- <br /> <br />I Hereby certify that the plans and <br />specifications covered by this calcu- <br />lation are in compliance with the <br />Florida Energy Code. <br /> <br />PREPARED BY: <br />DATE: <br /> <br />l~~ <br />.:2 -'14-4 <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br />I hereby certify that this building is <br />in compliance with the Florida Energy <br />Code. <br /> <br />OWNE~Q;~ ~ ~ <br />DATE: .2":::;:' -~ <br /> <br />BUILDING DFFIc~y..t:?<9<f d~~ <br />DA TE :;;;:;:>- -,/C)- <br />