My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
94-3858
Zephyrhills
>
Building Department
>
Permits
>
1994
>
94-3858
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 12:04:47 PM
Creation date
5/15/2006 9:04:42 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Building Department - Date
2/2/1994 12:00:00 AM
Permit #
94-3858
Building Department - Name
ZEPHYR DEVELOPMENT
Address
39301 SOUTH AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />Fire Chief <br />Robert Hartwig <br /> <br />ZEPHYRHILLS FIRE DEPARTMENT <br />Zephyrhills Florida 33540 <br /> <br />38410 6th Avenue <br /> <br />Bus (813) 782-8184 <br /> <br />Fax (813) 788-3293 <br /> <br />To: File <br />From: Robert Hartwig, Fire Chief <br />Re: Leheup Building @ South Ave & Airport Rd. <br />Date: 2/15/94 <br /> <br />Mr. Leheup: <br /> <br />Per our conversation on this date, I am approving <br />the plan as submitted, for the building of the 1 hour <br />rated fire wall, seperating the east and west halves. <br />In general there are three areas of concern in <br />subdividing this building. First, the 1 hour rated fire <br />wall. This item is addressed by permitting and const- <br />ruction of the wall with UL U469 classification. This <br />shall separate the east and west halves as well as <br />separation between the office area and the storage area <br />on the east side. Access to the bathrooms will be <br />allowed provided you construct the proper 1 hour encl- <br />osure and install a rated door and assembly. This wall <br />must be completed prior to occupancy of tne east side. <br />Secondly, I need current hydraulic calculations, from <br />the sprinkler company, based on the fire load conditions <br />of the new tenants storage contents. Verification of the <br />sprinkler system, for this ordinary hazard condition, <br />must be submitted prior to occupancy. <br />The last area of concern is the building's fire <br />alarm system/plans shall be submitted and approved for <br />one fire alarm system for the entire building. This <br />could be accomplished by utilizing the new system <br />installed by Sears and expanding upon it. Each occup- <br />ancy shall be appro~riataly zoned for smoke detectors, <br />duct detectors, and pull boxes. The sprinkler system <br />shall be independently zoned. Any general alarm in any <br />zone shall send notification to all portions of the <br />building. The alarm system shall be installed within <br />(60) days of occupancy by Lykes Pasco. <br /> <br /> <br />~_.-. . <br /> <br />Chief <br />
The URL can be used to link to this page
Your browser does not support the video tag.