Laserfiche WebLink
<br />SOIL TESTING <br />~ <br />FIELD DENSITY - PERCENTAGE <br />OF COMPACTION REPORT <br /> <br />"... <br /> <br />Florida Testing & Environmental, Inc. <br /> <br />PROJECT: <br /> <br />P.O. Box 937 <br />5316 Tangerine Dr. <br />Zephyr Heights - Lot #15 <br />Pasco County Permit #3880B <br /> <br />· Zephyrhills, Florida 33539. <br /> <br />TELEPHONE (813) 780-8767 <br />· FAX (813) 780-8864 <br /> <br />LAB NO: <br /> <br />4D <br /> <br />CLIENT: <br /> <br />Ridge Builders <br /> <br />TECHNICIAN: <br /> <br />Robert Bode <br /> <br />CONTRACTOR: <br /> <br />Ridge Builders <br /> <br />JOB NO: <br /> <br />93-5046 <br /> <br />WEATHER <br />CONDITIONS <br /> <br />Clear <br /> <br />DATE: <br /> <br />May 6, 1994 <br /> <br /> T <br /> ASTM D 2922 IN PLACE FIELD DENSITIES - DATE MADE 5-3-94 H <br /> I <br /> COMPACTION C <br /> K <br /> IN-SITU IN-PLA LAB. PERCENT N <br />TEST MOISTURE DRY MAX. E <br />NO. LOCATION OF TEST DENSITY DENSITY ATTAINED REQUIRED S <br /> PERCENT PCF PCF S <br /> BUILDING PAD <br />l. Center of Garage 3.6 107.1 107.1 100 95 <br />2. 30' N. & 12' W. of S.E. Corner 4.1 105.2 107.1 98 95 <br />3. 9' N. & 9' W. of S.E. Corner 4.5 104.9 107.1 98 95 <br /> <br />REPORT DISTRIBUTION: <br /> <br />3: Addressee <br /> <br /> <br />The percentage of compactIon for. the In-place density tests are based on laboratory Moisture Density Rela ns Tests <br /> <br />LAB NO. 3P <br /> <br />MAXIMUM DRY DENSITY 107.1 pcf <br /> <br />Artaart Prln'ers. (813) 665-9153 <br />