<br />WINTER POINT MULTIPLIERS (WPM) <br /> <br />CLIMATE ZONES 4 ~ & <br /> <br />6A-10 WINTER OVERHANG FACTORS (WOF) <br /> ~ OH RATIO I ,00-.11 I .12-.17 .18-.26 .27-,35 ,36- .46 .47-,57 I .58-.70 I .71-,83 .84-1.18 11.19-1.72 /1.73-2,73 I 2,74+ <br /> SINGLE PANE GLASS <br /> N 1.00 1.03 1.05 1,08 1.10 1,13 1.15 1.18 1,20 1.24 1.29 1.34 <br /> NE/NW 1.00 1.07 1,10 1.15 1.20 1.25 1,30 1.35 1.39 1.50 1.59 1.67 <br /> E/W 1.00 .71 .57 .19 -.20 -.65 -1.05 -1,48 -2.03 -3.01 -4.06 -5,04 <br />> SE/SW 1.00 .93 .90 .80 .68 ,54 ,39 .22 .05 -.33 -.71 -1.01 <br />III <br />tia: S 1,00 .95 .92 .83 ,70 ,54 .36 .13 -.13 -.70 -.98 -1.09 <br />we DOUBLE PANE GLASS <br />m[ N 1.00 1.05 1.07 1.11 1,14 1.18 1.21 1.24 1,28 1.34 1.40 1.47 <br />NE/NW 1.00 1.11 1,16 1.24 1.32 1.41 1.48 1.56 1.63 1.80 1.94 2.08 <br />E/W 1.00 .88 .82 .66 .50 .31 .15 -,03 -.26 -.66 -1.10 -1.50 <br />SE/SW 1.00 ,95 .92 .85 .76 .65 .54 .41 .28 -,01 -.30 -.52 <br />S 1.00 .96 .94 .87 .78 .65 .51 .33 .13 -.30 -.51 -.60 <br />OH LENGTH' Oft. 1 ft. 11;2 ft. 2 ft. 3ft. 3'12 ft. 41;2 ft. 51;2 ft. 61;2 ft, 9'12 ft. 14ft. 20ft,+ <br /> 'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT, BELOW THE OVERHANG. <br /> <br />6A-11 WALL WINTER POINT MULTIPLIERS WPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6.8 5.3 <br />2.5 2.1 <br />2.0 1.8 <br />1.8 1,6 <br />1.1 1.0 <br />.7 .7 <br /> <br />R.VALUE <br />0-6,9 <br />7-10.9 <br />11-12.9 <br />13-18.9 <br />19-25,9 <br />26& U <br /> <br />STEEL <br />EXT ADJ <br />9.4 6.7 <br />4.4 3.3 <br />3.3 2,6 <br />3.0 2.4 <br />2.6 2.2 <br />1.4 1.2 <br /> <br /> <br />CONCRETE BLOCKl <br />INT. INSULATION <br />NORMAL WT. <br />EXT ADJ <br />6.0 3,1 <br />3.8 2.3 <br />2,9 1.9 <br />2.3 1.5 <br />1.5 1.1 <br />.8 .7 <br />.5 .5 <br /> <br /> <br />6A.12 DOOR WINTER POINT MULTIPLIERS <br />DOOR TYPE EXTERIOR ADJACENT <br />WOOD 7.6 5.9 <br />INSULATED 5.1 4.0 <br /> <br />WPM) <br /> <br />6A-13 CEILING WINTER POINT MULTIPLIERS (WPM) <br />UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOFING <br />R-VALUE WPM R-V ALUE WPM CEILING TYPE <br />19-219 1.0 10-10.9 1.8 R-V ALUE DROPPED EXPOSED <br />22-25.9 .9 11-12.9 1.6 10-13,9 1.2 1.3 <br />26-29.9 .7 13-18.9 1.5 14-20,9 .7 .7 <br />30-37.9 .6 19-25.9 1.1 21 & Uo .4 .3 <br />38 & Uo .4 26-29.9 .6 <br /> ::In JI. Un <1 <br /> <br />6A-14 FLOOR WINTER POINT MULTIPLIERS (WPM) <br />SLAB-aN-GRADE RAISED RAISED WOO[)2 <br />u< POST OR PIER STEM WALL wI UNDER <br />EDGE INSULATION CONCRETE C CONSTRUCTION FLOOR INSULATION ADJACENT <br />R-V ALUE WPM R-VALUE WPM R-V ALUE WPM WPM WPM <br />0-2.9 2.5 > 0-2.9 4.0 0-6,9 7.9 N/A 5.3 <br />3-4,9 -1.7 3-4.9 1.8 </ 7-10.9 2,1 ,7 2.1 <br />5-6.9 -2.4 5-6.9 1.1 11-18.9 1.5 .5 1.8 <br />7 & Iln -? 7 7 Jl.lln II 1/ 10 R. Iln 0 ::I 1 n <br /> <br />6A.15 INFILTRATION WINTER POINT MULTIPLIERS (WPM) <br />INFILTRATION PRACTICE WPM <br />SEE TABLE gp <br />PRACTICE #1 6.2 <br />PRACTICE #2 4.1 <br /> <br />6A-16 DUCT MULTIPLIERS OM <br /> <br />SUPPLY DUCTS IN <br />UNCONDITIONED SPACE <br /> <br /> <br />RETURN DUCTS <br />IN UNCONDITIONED SPACE <br />1,14 <br />1.10 <br />1.09 <br />1.10 <br />1.07 <br /> <br />RETURN DUCTS <br />IN CONDITIONED SPACE <br />1.10 <br />1,07 <br />1.06 <br />1.00 <br />1.00 <br /> <br />SUPPLY DUCTS IN <br />ONDITIONED SPACE' <br /> <br />6A-17 HEATING SYSTEM MULTIPLIERS (HSMI <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS (HSM) <br />Central Heat HSPF 6.40-6.79 6.80-6.89 6.90-7,39 7.40-7.89 7.90-8.39 8.40-8.89 8.9-9.39 9.4-9.89 <br />Pump Units HSM .53 .50 .49 .46 .43 .41 .38 ,36 <br /> HSPF 9.90-10.39 10.40-10.89 10.90-11.39 11.40-11.89 11.90-12.39 12.40 & uo <br /> HSM .34 .33 .31 .30 .29 .28 <br />PTHP COP 2.50-2.69 2.70-2,89 2.90-3.09 3.10-3.29 3,30-3.49 3.50-3.69 3.70-3.89 3.90-4.19 <br /> HSM .38 .37 .34 .32 .30 .29 .27 .26 <br />Electric Strio 1.0 <br />Gas & Other Fuels 1.0 (See Table 6A-18 for Credit Multinlier\ <br />MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF. SINGLE PKG. 6.6 HSPF, WATER SOURCE 3.8 COP, GROUND WATER SOURCE 3.4 COP, PTHP 2.5-2.7 COP, <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2,1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />.5- <br />