<br />. ADDITIONAL TABLES <br /> <br />CLIMATE ZONES 4' 5 6 <br /> <br />6M8 HEATING CREDIT MULTIPLIERS (HCM) <br />SYSTEM TYPE HEATING CREDIT MULTIPLIERS (HCM) <br />Attic Radiant Barrier HCM .98 <br />Multizone HCM .90 <br />Natural Gas AFUE .68-,72 .73-.77 .78-,82 ,83-.87 .88-,92 ,93 & Uo <br />HCM .61 .56 .53 ,50 .47 ,44 <br />LP Gas HCM .77 .72 .67 .63 .60 .57 <br /> <br />6A.19 COOLING CREDIT MULTIPLIERS CCM) <br />SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) <br />Ceilina Fans ,86' <br />Cross Ventilation .90' 'Credit may be taken for only <br />Whole House Fan .90' <br />Multizone .95 one of these system types concurrently, <br />Attic Radiant Barrier .95 <br /> <br />6A.20 HOT WATER CREDIT MULTIPLIERS (HWCM) <br />SYSTEM TYPE HOT WATER CREDIT MULTIPLIERS IHWCM) <br />Heat Recovery Unit With Air Conditioner Heat Pumo <br />HWCM .62 .58 <br />Dedicated Heat Pump EF 2.0-2.49 I 2.5-2,99 3.0-3.49 I 3.5 & Uo <br />HWCM ,44 I ,35 .29 I .25 <br /> A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM. SEE TABLE 6A-9. EF MEANS ENERGY FACTOR. <br /> <br />6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 606.1 COMPLY WITH All INFilTRATION PRESCRIPTIVES, <br />Windows 606.1 Maximum of 0.34 CFM oer linear foot of operable sash crack (includes slidina alass doors), <br />Exterior & Adiacent Doors 606.1 Maximum of 0.5 CFM per sa, ft. of door area; solid core, wood panel, insulated or alass doors onlv. <br />Exterior Joints & Cracks 606.1 To be caulked, aasketed, weatherstripped or otherwise sealed. <br />PRACTICE #2 606.2 COMPLY WITH #1 AND THE FOllOWING: <br />Exterior Walls and Floors Top plate penetrations sealed, Infiltration barrier installed. Sole plate/floor ioint caulked or sealed. <br />Exterior Walls & Ceilings Penetrations, ioints and cracks on interior surface caulked, sealed or oasketed. <br />Ductwork Ductwork in unconditioned soace must be sealed. <br />Fireolaces Eauipped with outside combustion air, doors, and flue dampers. <br />Exhaust Fans Eauioped with dampers. Combustion devices see 606,1.A.2 <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust to outside, <br /> Cookina appliances shall be dampered and use intermittent ianition. <br />PRACTICE #3 606.2 COMPLY WITH PRACTICES #1 AND #2 AND THE FOllOWING: <br />Ceilinas Infiltration barrier installed. <br />Interior Walls Top penetrations sealed or ioints & cracks on interior walls caulked, sealed or aasketed. <br />Recessed Liahts Sealed from conditioned & insulated from ventilated attic spaces, <br />Ductwork All ductwork located in conditioned space. <br /> <br />6A-22 OTRiR PRESCRIPTIVE MEASURES lmust be met or exceeded bv all residences.! <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) <br /> or cutoff laas! must be nrovided. External or built-in heat tran reauired. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have <br /> a pump timer, Gas spa & 0001 heaters must have a minimum thermal efficiencv of 78%. <br />Shower Heads 612.1 Water flow must be restricted to no more than 3 aallons per minute at 80 PSIG. <br />HVAC Duct Construction 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />Insulation & Installation sealed, insulated, and installed in accordance with the criteria of Section 904.6. Duct in unconditioned <br /> space and air handlers located in attics must be insulated to a minimum of R-6, Air handlers shall not <br /> be installed in attics unless in mechanical closet. <br />HV AC Controls 607.1 Seoarate readilv accessible manual or automatic thermostat for each svstem. <br />Insulation 604.1 602.1 Ceilinas-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceilina & floors R-11. <br /> <br />-6- <br />