My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
94-4130
Zephyrhills
>
Building Department
>
Permits
>
1994
>
94-4130
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 12:03:54 PM
Creation date
6/1/2006 8:25:47 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
94-4130
Building Department - Name
GUDE BROTHERS
Address
6747 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />,'..., o. :o.'!.~~i}';;-;~.l'~1:': <br /> <br />P_12l2 <br /> <br />~ .Specifications for }.,ead Shieldi~g <br /> <br />A. Th.e shielding must extend from the floor to a height Of seven fe~t <br />cQntioU(lusly, with 'no holest gaps or omissions. Any perfQration$ in the <br />shielding (such as for electrical boxes, switches, view boxes, etc.) must he <br />covered or ba<.~ked by lead sheeting of thkkness not less than that which is <br />used itl adjacent walls in order to maintain shielding continuity. In t.be event <br />the seven foot level as' measured from the interior of the room being shield- <br />ed does not provide shielding to a height of seven feet to an occupieda'rea <br />on the other side of that wall, addjtjonal shielding may be required. This <br />si~uatjon has been observed when the floor of the room being ~hielding is <br />either SIigJltly below grade or during a renovation the new area is between <br />floor levels of the old area. ! <br /> <br /> <br />B. .Eachshect of lead must overlap the next by at least one-quarter inch <br />(1/4") and it is not necessary that fasteners be of the lead-head va.riety. or be <br />covered with lead so long as no fastener is removed leaving a hole in the <br />shielding. <br /> <br /> <br />c. An doors and door frames installed into lead. lined walls in this room <br />must provide shielding the equivalence of the lead thickness which is re- <br />quired for the walJ into which the door is installed. This is most simply and <br />accurately assured by using doors and door frames lined with the appro- <br />priate thickness of lead; provisions must be made to assure that the hard- <br />ware used is suitable for the increased weight of this door. <br /> <br />D. The leaded acrylic or leaded glass window in the Control Barrier must <br />provide protection of lead equivalence not less than the Control Barrier wall <br />in which it is installed and must he framed in lead so designed as to assure <br />shielding continuity and integrity. There must also be an accomm<wation <br />for clear communication between the operator and the patjent. "'.':~ <br /> <br />E. Additional shielding must be placed behind the wall mounted ca.ssette <br />bolder for chest radiography; a four feet by seven feet (4'X7') sheet of 1.0 <br />mm of lead must be centered behind the wall nlountcd cassette for chest <br />radiog"raphy in order to accommodate this routine ptin1ary exposure. The <br />cbest Dack must not be placed on the same wall as the entrance to the opE;ra~ <br />tor protected area behind the Control Barrier. <br /> <br />.._-_..~~~----~---.,.--~-~.~----~-~---~_.. ------- <br /> <br />P.03 <br />
The URL can be used to link to this page
Your browser does not support the video tag.