Laserfiche WebLink
<br />C <br />E <br />I <br /> <br />Catalano Engineering, Inc. <br />CIVIL. TRANSPORTATION. STRUCTURAL <br /> <br />August 9, 1994 <br />94-145.01 <br /> <br />Mr. Clay Whitworth <br />Whitworth Builders <br />4833 Handcart Road <br />Zephyrhills, Florida 33544 <br /> <br />RE: Swingle Residence <br /> <br />Dear Mr. Whitworth, <br /> <br />As requested, I have examined the effects to the lanai beam of adding an additional <br />column. <br /> <br />Because adding an additional postlcolumn reduces the uplift component per post, Simpson <br />PB44 Post Bases will suffice in lieu of the CB44 bases which had been originally specified. <br />The additional post should be installed roughly centered (+/- 10%). This post base will <br />also apply to the covered porch at the front entry of the home. <br /> <br />Also during our conversation, it was noted that the typical wall section specified an anchor <br />bolt spacing of 36" o.c. Please disregard this spacing and install anchor bolts at 48" O.c. <br /> <br />Thank you for this opportunity to be of service to Whitworth Construction. <br /> <br /> <br />812 S. Lakeview Road · Tampa, Florida 33609. Phone/FAX (813) 877-4004 <br />