Laserfiche WebLink
<br />Departrnent of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 6boA-93 Residential Whole Building Performance Method A <br />PROJECT NAME: OAK RUN APT~. ,,: BUILDER: <br />AND ADDRESS :(/d'17tJ/-I-/1 &a~"/f..~ : PERMITT~lNG " : CLIMATE <br />1\ ZEPHYRHILLS, FL. : OFF-ICE: : ZONE: 4: ~ 5: _: 6:_: <br />OhINER: 17 1l.n :PERMIT 0. :JURISDICTION NO.G.-I/'='Ou <br />.-<5 CL/h. ~ R:J IVV - C K <br />1. New constr~ction or addition 1. New Construction <br />~ Single family detached or Multifamily attached 2. Single-Family <br />3. If Multifamily-No. of units 3. 60 <br />4. If Multifamily, is this a worst case (yes/no) 4. <br />5. Conditioned floor area (sq.ft.) 5. 954.00 <br />6. Predominant eave overhang (ft.) 6. 2.00 <br />7. Porch overhang length (ft_) 7. 0.00 <br />8. Glass area and type: Single Pane <br />a. Clear Glass 8a.l04.0sqft <br />b. Tint, film or solar screen 8b. O.Osqft <br />9. Floor type and insulation: <br />a. Slab on grade (R-value, perimeter) <br />10.Net Wall type area and insulation: <br />a. Exterior: 1. Concrete (Insulation R-value) <br />b. Adjacent: 1. Concrete (Insulation R-value) <br />11.Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />12.Air distribution systems <br />a. Ducts (Insulation + Location) <br />13~Cooling system <br /> <br />14.Heating System: <br /> <br />15.Hot water <br /> <br />system: <br /> <br />16.Hot Water Credits: (HR-Heat Recovery, <br />DHP-Dedicated Heat Pump) <br />17.Infiltration practice: 1, 2 or 3 <br />18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />19.EPI (must not exceed 100 points) <br />a. Total As-Built points <br />b. Total Base points <br /> <br />G..J <br /> <br />SN: <br /> <br />6349 <br /> <br />CENTF~AL <br /> <br />Double Pane <br />'O.OOsqft <br />O.OOsqft <br /> <br />9a.R'" 0.00 , <br /> <br />51.50 ft <br /> <br />10a-l R= 5.00, 260.00sqft__.._ <br />10b-1 R= 5.00, 20.00sqft____.w_. <br /> <br />11a.R=30.00 , 985.00sqft____ <br /> <br />12a. R'" 6.00, uncond <br />13. Type: Central A/C <br />SEER: 10.15 <br />14. Type: Strip Heat <br />COP: 1.00 <br />15. Type: Electric <br />EF: 0.89 <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br /> <br />19. <br />19a. <br />19b. <br /> <br />98.31 <br />19419.16 <br />19752.21 <br /> <br />------------------------------------------------------------------------------- <br /> <br />-------------------------------------------------------------------------------- <br /> <br />I Hereby certify that the plans and <br />3pecifications covered by this calcu- <br />lation are in com liance with the <br />~lorida Energy 0 e. ~ <br /> <br />~REPARED BY: . <br />} J-- . 4. --..- ------...-.... <br />) ATE : ____2/__1_ .r.....:L.f---.-.-.--....-..-..-----.-.-.-.-. <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br /> <br />I hereby cel.tify that this building is <br />in compliance with the Florida Energy <br />:::ode. <br /> <br />~~~~~I~~Z:?;'~~~ _ <br /> <br />)WNER/AGENT: <br />)ATE: <br />