Laserfiche WebLink
<br />Department of Community Affairs <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 600A-93 Residential Whole Building Performance Method A <br />PROJECT NAME: OAK RUN ~PlS. . : BUILDER: <br />AND ADDRESS :3i>~/i./+r:2'f cY~l1~ i, PERMITT.~ING '. : CLIMATE ./ <br />~ jEPHYRHILL5, fL. I OffICE. : ZONE: 4:~: 5:~: 6: __: <br />Qt'JNER.: J4 : PERl'lI T ,C. : JURISDICTION NO. G.r//~Ou <br />~~ Q .vv CK <br />1. New construction or addition 1. New Construction <br />2. Single family detached or Multifamily attached 2. Single-Family <br />3. If Multifamily-No. of units 3. 60 <br />1. If Multifamily, is this a worst case (yes/no) 4. <br />5. Conditioned floor area (sq.ft.) 5. 954.00 <br />6. Predominant eave overhang (ft.) 6. 2.00 <br />7. Porch overhang length (ft.) 7. 0.00 <br />8. Glass area and type: Single Pane <br />a. Clear Glass 8a.104.0sqft <br />b. Tint, film or solar screen 8b. O.Osqft <br />9. Floor type and insulation: <br />a. Slab on grade (R-value, perimeter) <br />10.Net Wall type area and insulation: <br />a. Exterior: 1. Concrete (lnsulation R-value) <br />b. Adjacent: 1. Concrete (Insulation R-value) <br />11.Ceiling type area and insulation: <br />a. Under attic (Insulation R-value) <br />12.Air distribution systems <br />a. Ducts (Insulation + Location) <br />13.Cooling system <br /> <br />14.Heating System: <br /> <br />15.Hot wate'( <br /> <br />S)/stem: <br /> <br />16.Hot Water Credits: (HR-Heat Recovery, <br />DHP-Dedicated Heat Pump) <br />17.Infiltration practice: 1, 2 or 3 <br />18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, <br />HF-Whole house fan, RB-Attic radiant <br />barrier, MZ-Multizone) <br />19.EPI (must not exceed 100 points) <br />a. Total As-Built points <br />b. Total Base points <br /> <br />GJ <br /> <br />SN: 6349 <br /> <br />CENTF\AL <br /> <br />Double Pane <br />'O.OOsqft <br />O.OOsqft <br /> <br />9a.R~ 0.00 , <br /> <br />51.50 ft <br /> <br />10a-l R= 5.00, 260.00sqft.___ <br />10b-l R= 5.00, 20.00sqft________. <br /> <br />l1a.R=30.00 , 985.00sqft____ <br /> <br />12a. R~ 6.00, uncond <br />13. Type: Central A/e <br />SEER: 10 .15 <br />14. Type: Strip Heat <br />COP: 1 .00 <br />15. Type: Electric <br />EF: 0.89 <br /> <br />16. <br /> <br />17. <br />18. <br /> <br />2 <br /> <br />19. <br />19a. <br />19b. <br /> <br />98.31 <br />19419.16 <br />19752.21 <br /> <br />------------------------------------------------------------------------------- <br /> <br />-------------------------------------------------------------------------------- <br /> <br />I Hereby certify that the plans and <br />3pecifications covered by this calcu- <br />Lation are in com liance with the <br /> <br />:~:::::D. E:;~: 0 e. . ~4-~. <br /> <br />)A T E-: : ____2 1- --r--~------..------------.--..-- <br /> <br />[ hereby cel-ti fy that this bui Idi ng is <br />Ln compliance with the Florida Energy <br />:ode. <br /> <br /> <br />)WNER/AGENT: <br />)ATE: <br /> <br />--_._--_..~..~~._."-~".,,~.~,,~---_.._.~-~~..~.,,.._-----~....~._-~~~._,._-'".._...- <br /> <br />~----.----...--.~~.---~---~~. ~..-"-..,...--.--~---___~_~"'_ '_....~_"..". ...._~.__w_.,. .~~~___._._ <br /> <br />Review of the plans and specifications <br />covered by this calculation indicates <br />compliance with the Florida Energy <br />Code. Before construction is completed <br />this building will be inspected for <br />compliance in accordance with Section <br />553.908 F.S. <br /> <br />~~~~~I~~;t,~~~ <br />