Laserfiche WebLink
<br />Ratz Residence <br /> <br />Height: 0-15 15-20 20-40 40-60 Total <br />Resisting Moment: 2698.8 2698,8 2698.8 2698.8 2698.8 <br />x 2/3 = 1799.2 1799.2 1799.2 1799.2 1799.2 <br />Uplift Moment: -1573.7 0.0 0.0 0.0 -1573.7 <br />Hz. Pres. Moment : -216,2 -85.5 0.0 0.0 -301.7 <br />Overturning Mmt. = -1789.9 -85.5 0.0 0.0 -1875.4 <br /> <br />. Ii:; <br /> <br />Note: If OM < 2/3 RM, hold-downs are not required. <br /> <br />Required tie-down force (T): <br /> <br />( Factor of Safety 'built in' to Mfr's tables.) <br /> <br />Therefore: T x b + RM > or = OM. <br />where, b= building width. <br /> <br />T = (OM-RM) 1 b = I -14972 Ilbs <br /> <br />** Specify tie-down accordingly, FS 'built in' to Mfr's tables. <br /> <br />x.) Girder Uplift: <br />1.) Two (2) Point Bearing, Symmetric. <br /> <br />Girder Contrib. area (sf) Height (ft) Net Uplift (psf) Uplift per brg. <br />Gar-l 294.7 12,8 -9.2 -1355.7 <br /> 12.8 -9.2 0.0 <br /> 12,8 -9.2 0.0 <br /> <br />Girder <br />Mark <br /> <br />2.) Other configurations ie, three (3) point brg. <br />Contrib. Height (ft) <br />area (sf) (Mn. roof) <br />12.8 <br />12.8 <br /> <br /> <br />N/A <br /># Brg, <br />Points <br /> <br />Max. Uplift <br />Reaction (Ibs) <br /> <br />Page 7 <br /> <br />