My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
95-4882 (2)
Zephyrhills
>
Building Department
>
Permits
>
1995
>
95-4882 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 2:40:54 PM
Creation date
6/15/2006 11:48:50 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
94-4882
Building Department - Name
BROWN, R
Address
4769 SILVER OAKS
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />-WINTER POINT MULTIPLIERS (WPM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A.l0 WINTER OVERHANG FACTORS lWOF) <br />J OH RA no I .00-.11 .12-.17 .18-.26 I .27-.35 I .36-.46 I .47-.57 .58-.70 .71-.83 .84-1.18 r1.19-1.72 1.73-2.73 2.74+ <br /> SINGLE PANE GLASS .- <br />N 1.00 1.03 1.05 1.08 1.10 1.13 1.15 . 1.18 ) 1.20 1.24 1.29 1.34 <br />NElNW 1.00 1.07 1.10 1.15 1.20 1.25 1.30 1.35 1.39 1.50 1.59 1.67 <br />E/W 1.00 .71 .57 r'19J -.20 -.65 -1.05 -1.48 -2.03 -3.01 -4.06 -5.04 <br />SElSW 1.00 .93 .90 ---:lio .68 .54 .39 .22 .05 -.33 -.71 -1.01 <br />I-a: S (1.00 ) .95 .92 .83 .70 .54 .36 .13 -.13 -.70 -.98 -1.09 <br />~[ '. . DOUBLE PANE GLASS <br />N 1.00 1.05 1.07 1.11 1.14 1.18 1.21 1.24 1.28 1.34 1.40 1.47 <br />NElNW 1.00 1.11 1.16 1.24 1.32 1.41 1.48 1.56 1.63 1.80 1.94 2.08 <br />E/W 1.00 .88 .82 .66 .50 .31 .15 -.03 -.26 -.66 .1.10 -1.50 <br />SElSW 1.00 .95 .92 .85 .76 .65 .54 .41 .28 -.01 -.30 -.52 <br />S 1.00 .96 .94 .87 .78 .65 .51 .33 .13 -.30 -.51 -.60 <br />OH LENGTH. Oft. 1 ft. 1'h ft. 2ft. 3ft. 3'hft. 4'hft. 5'h ft. 6'h ft. 9% ft. 14 ft. 20ft.+ <br /> 'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT. BELOW THE OVERHANG. <br /> <br />6A-11 WALL WINTER POINT MULTIPLIERS PM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6.8 5.3 <br />2.5 2.1 <br />2.0 <br />1.8 <br />1.1 <br />.7 <br /> <br />CONCRETE BLOCK' <br />INT. INSULATION <br />NORMAL WT. <br />EXT ADJ <br />6.0 3.1 <br />3.8 2.3 <br />1.9 <br />1.5 <br />1.1 <br />.7 <br />.5 <br /> <br /> <br /> <br />6A.12 DOOR WINTER POINT MULTIPLIERS <br />DOOR TYPE EXTERIOR ADJACENT <br />WOOD 7.6 5.9 <br />INSULATED @ (4.0) <br /> <br />WPM) <br /> <br />6A-13 CEILING WINTER POINT MULTIPLIERS /wPMI <br />UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF <br />R-VALUE WPM R-VALUE WPM CEILING TYPE <br />19-21.9 / 1.0.,)- 10-10.9 1.8 R-VALUE DROPPED EXPOSED <br />22-25.9 .9 11-12.9 1.6 10-13.9 1.2 1.3 <br />26-29.9 . .7 13-18.9 1.5 14-20.9 .7 .7 <br />30-37.9 .6 19-25.9 1.1 21 & Un .4 .3 <br />38 & Uo .4 26-29.9 .6 <br /> .~ A <br /> <br /> <br />RAISED W0002 <br />POST OR PIER STEM WALL wI UNDER <br />CONSTRUCTION FLOOR INSULATION <br />WPM WPM <br />7.9 1.8 <br />~1 .7 <br />1.5 .5 <br /> <br />ADJACENT <br /> <br />WPM <br />5.3 <br />2.1 <br />1.8 <br /> <br /> 6A-16 DUCT MULTIPLIERS /OMI <br /> RETURN DUCTS RETURN DUCTS <br /> R-VALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE <br /> SUPPLY DUCTS IN 4.2-5.9 1.14 1.10 <br /> 6.0-6.6 (1.10 ) 1.07 <br /> UNCONDITIONED SPACE 6.7 & Uo 1.09 1.06 <br /> SUPPLY DUCTS IN 4.2.5.9 1.10 1.00 <br /> CONDITIONED SPACE3 6.0-6.6 1.07 1.00 <br /> f; 7 R.lln 1M 1M <br />6A-17 HEATING SYSTEM MULTIPLIERS /HSM\ <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS IHSM\ <br />Central Heat HSPF 6.40-6.79 6.80-6.89 6.90-7.39 ) 7.40-7.89 7.90-8.39 8.40-8.89 8.9-9.39 9.4-9.89 <br />Pump Units HSM .53 .50 "- .49./ .46 .43 .41 .38 .36 <br /> HSPF 9.90-10.39 10.40-10.89 10.90-11.39 11.40-11.89 11.90-12.39 12.40 & uo <br /> HSM .34 .33 .31 .30 .29 .28 <br />PTHP COP 2.50-2.69 2.70-2.89 2.90-3.09 3.10-3.29 3.30-3.49 3.50-3.69 3.70-3.89 3.90-4.19 <br /> HSM .40 .37 .34 .32 .30 .29 .27 .26 <br />Electric Strio 1.0 <br />Gas & LP Gas 1.0 (See Table 6A-18 for Credit Multiolierl <br /> MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF, SINGLE PKG. 6.6 HSPF, WATER SOURCE 3.8 COP. GROUND WATER SOURCE 3.4 COP, PTHP SEE TABLES 6-6 TO 6-8. <br /> <br />6A-15 INFILTRATION WINTER POINT MULTIPLIERS (WPM) <br />INFILTRATION PRACTICE WPM <br />SEE TABLE 6A-21 <br />PRACTICE #1 <br />PRACTICE #2 <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />.5. <br />
The URL can be used to link to this page
Your browser does not support the video tag.