Laserfiche WebLink
<br />** INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST ** <br /> <br />~===~=~~=========~============================================================ <br /> <br />COMP-ONENTS <br /> <br />SECT I m~ <br /> <br />REQUIREMENTS FOR EACH PRACTICE <br /> <br />CHECK <br /> <br />=============================================================================== <br /> <br />PRACTICE #1 <br /> <br />l.J i ndov,Js <br /> <br />Exterior & <br />Adjacent Doon3 <br /> <br />E:<tel" iOl" .Jo i nts <br />& Cracks <br /> <br />PRAC T ICE: #2 <br /> <br />Exterio'( IrJalls <br />;5< F loo!":;:; <br /> <br />Exterior Walls <br />& Ceilings <br /> <br />DucU,Jor k <br /> <br />F: i replaces <br /> <br />Exhaust Fans <br /> <br />combustion <br />Appliances <br /> <br />606.1 <br /> <br />606.1 <br /> <br />606,1 <br /> <br />606.1 <br /> <br />E)06.1 <br /> <br />GOt., .1 <br /> <br />606.1 <br /> <br />606.1 <br /> <br />606.1 <br /> <br />606.1 <br /> <br />606.1 <br /> <br />COMPLY WITH All INFILTRATION PRESCRIPTIVES. <br /> <br />Maximum of 0.34 CFM per linear foot of operable sash <br />crack (includes sliding glass doors). <br /> <br />Maximum of 0.5 CFM per sq. ft. of door area: solid <br />core, wood panel,insulated or glass doors only. <br /> <br />To be caulked, gasketed, weather-stripped or other- <br />~-.)ise sealed. <br /> <br />COMPLY WITH PRACTICE #1 AND THE FOllOWING: <br /> <br />Top plate penetrations sealed. Infiltration barrier <br />installed. Sole plate/floor joint caulked or sealed. <br /> <br />Penetrations, joints and cracks on interior surface <br />caulked, sealed or gasketed. <br /> <br />Ductwork in unconditioned space must be sealed. <br /> <br />Equipped with outside combustion air, doors and flue <br />dampers. <br /> <br />Equipped with dampers. Combustion devices see <br />606.1.A.2. <br /> <br />Be in unconditioned space (except direct vent), draw <br />air from unconditioned space, exhaust to outside. <br />Cooking appliances shall be dampered and use <br />intermittent ignition. <br /> <br />** OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) ** <br /> <br />Wa tel" Hea te'r ~:'} <br /> <br />Swimming Pools <br />;.5< ~:)pas <br /> <br />ShOW,,}l" Head~3 <br /> <br />I-NAC Duct <br />Construction <br />Insulation ,3, <br />Installation <br /> <br />HVAC Contl"ols <br /> <br />Ins~ulat.ion <br /> <br />612.1 <br /> <br />t,12.1 <br /> <br />612.1 <br /> <br />610.1 <br /> <br />607.1 <br /> <br />604.1 <br />602.1 <br /> <br />Comply with efficiency requirements in Table 6-12. <br />Switch or clearly marked circuit breaker (electric) <br />or cutoff (gas) must be provided. External or built- <br />in heat trap required. <br /> <br />Spas and heated pools must have covers (except solar <br />heated). Non-commercial pools must have a pump timer. <br />Gas spa & pool heaters must have a minimum thermal <br />efficiency of 78 percent. <br /> <br />Water flow must be restricted to no more than 3 gal- <br />lons per minute at 80 PSIG. <br /> <br />All ducts, fittings, mechanical equipment and plenum <br />chambers shall be mechanically attached, sealed. ins- <br />ulated and installed in accordance with the criteria <br />of Section 610.1.ABC.2 & b10.1.ABC.3. Duct in attics <br />must be insulated to a minimum of R-6. Air handlers <br />shall not be installed in attics unless in mechanical <br />closet. <br /> <br />Separate readily accessible manual or automatic <br />thermostat for each system. <br /> <br />Ceilings minimum R-19. Common Walls - Frame R-l1 or <br />CBS R-3 both sides. Common ceiling & floors R-l1. <br />